Get a Quote
MINING & TUNNELING CABLES TEBAOFLEX

Type G Cable 2 kV Portable Mining Power Cable

Type G Cable is a 2,000 V portable power cable for stated industrial and mining applications requiring grounding.

  • Conductors: flexible stranded bare or tin-coated copper
  • Insulation: colour-coded 90°C EPDM
  • Ground wires: green EPDM-insulated copper
  • Jacket: flame-retardant, oil- and sunlight-resistant CPE
  • Size range: 8 AWG to 500 MCM

Request Type G Mining Cable pricing with the conductor count, gauge, length and application details.

Product information
Brand
TEBAOFLEX
Product overview

Type G Cable 2 kV portable mining power cable

TEBAOFLEX Type G Cable is a 2,000 V portable power cable for three- and four-wire AC systems requiring grounding. The supplied Type G Mining Cable information identifies industrial and mining uses, including mining equipment, cranes, conveyors, mobile equipment, electromagnets and oil-drilling equipment. Its stated design combines flexible annealed stranded copper conductors, colour-coded EPDM insulation, multiple insulated grounding conductors and a reinforced thermoset CPE jacket.

The Type G Cable configuration uses the same number of ground wires as primary conductors. The supplied information states that the total ground-wire cross-sectional area is roughly equal to that of the primary conductors. This arrangement, along with the supplied EPDM insulation and CPE outer jacket, is intended for portable cable duties exposed to heat, acids, oil, moisture and demanding environmental conditions.

  • Voltage rating: 2,000 V.
  • Temperature range: −40°C to +90°C.
  • Available construction: three or four pure stranded copper phase conductors with three or four green ground wires.
  • Size range: 8 AWG to 500 MCM.

For the final Type G Mining Cable selection, confirm conductor count, size, equipment connection, route, ambient conditions, required approvals, length and documentation. Explore the mining and tunneling cable range for related portable cable constructions.

Construction

Type G Cable construction

The supplied Type G Cable design uses flexible copper phase conductors and matching green grounding conductors within EPDM insulation and a reinforced CPE outer jacket.

Type G Cable cutaway showing coloured insulated copper conductors, green grounding conductors and black CPE jacket
Type G Cable construction view; final core count and configuration follow the approved order drawing.
Construction elementSupplied Type G Mining Cable reference
Phase conductorsFully annealed stranded bare or tin-coated copper; rope-lay stranding for flexibility
InsulationPremium-grade colour-coded 90°C ethylene-propylene-diene monomer (EPDM)
Ground conductorsGreen EPDM-insulated bare or tinned copper stranding; same number as primary conductors
Ground-wire areaTotal area stated as roughly equal to the primary-conductor cross-sectional area
Outer jacketFlame-retardant, oil- and sunlight-resistant chlorinated polyethylene (CPE), rated 90°C
OptionsOther sizes, colours and custom designs on request; EPR available on request
Applications

Applications

Type G Mining Cable is supplied for portable power duties on three- and four-wire AC systems requiring grounding. The supplied applications include mining equipment, cranes, conveyors, mobile equipment, electromagnets and oil-drilling equipment. Type G Cable is also described for temporary power supply duty in industrial and mining use.

Type G Mining Cable connected to underground mining equipment in a wet mine environment
Underground mobile-equipment connection illustrating a Type G Mining Cable application.

Selection checks

  • Confirm whether a three- or four-conductor Type G Cable configuration is required, together with the grounding arrangement.
  • Check the conductor size against load, voltage drop, route, protective device and installation conditions.
  • Review exposure to impact, abrasion, heat, acids, oil, moisture and weather with the actual site engineering requirements.
  • Specify the required length, colour code, jacket option, approvals and documentation with the enquiry.

The supplied Type G Cable construction is not interchangeable with Type G-GC or Type GC cable arrangements: confirm the required ground and ground-check functions before final selection.

Specifications

Type G Cable specifications

The following nominal four-conductor Type G Cable data is transcribed from the supplied information. All dimensions are nominal and subject to normal manufacturing tolerance.

Conductor sizeNo. of conductorsStrandingGround conductorInsulation thicknessApprox. diameterNet weight
8 AWG41334 × 12 AWG1.520 mm (0.060 in)26.540 mm (1.045 in)945 kg/km (635 lb/MFT)
6 AWG42594 × 12 AWG1.520 mm (0.060 in)28.580 mm (1.125 in)1,339 kg/km (900 lb/MFT)
4 AWG42594 × 10 AWG1.520 mm (0.060 in)30.730 mm (1.210 in)1,905 kg/km (1,280 lb/MFT)
2 AWG42594 × 9 AWG2.030 mm (0.080 in)36.450 mm (1.435 in)2,976 kg/km (2,000 lb/MFT)
1/0 AWG42594 × 7 AWG2.030 mm (0.080 in)43.69 mm (1.720 in)4,672 kg/km (3,140 lb/MFT)
2/0 AWG42594 × 6 AWG2.030 mm (0.080 in)47.240 mm (1.860 in)5,625 kg/km (3,780 lb/MFT)
3/0 AWG42594 × 5 AWG2.030 mm (0.080 in)52.710 mm (2.075 in)6,696 kg/km (4,500 lb/MFT)
4/0 AWG42594 × 5 AWG2.030 mm (0.080 in)54.740 mm (2.155 in)8,214 kg/km (5,520 lb/MFT)
500 MCM41,2354 × 1/0 AWG2.413 mm (0.095 in)86.400 mm (3.400 in)16,008 kg/km (10,758 lb/MFT)

Additional supplied size references

Conductor sizeStrandingGround conductorInsulation thicknessOutside diameterMaterial weight
250 kcmil4274 × 3 AWG0.095 in2.77 in7,143 lb/M
350 kcmil8884 × 2 AWG0.095 in3.10 in6,567 lb/M

For shared sizes, source tables supplied for this page show differing nominal weights and dimensions. Confirm the approved manufacturing drawing and final quotation data before ordering.

Standards

Standards and supplied approval references

The supplied Type G Cable information lists the following standards and approval/compliance references.

StandardsCSA FT5; ASTM B172 and B33; MSHA P-7K-268101; ICEA S-75-381 / NEMA WC-58; ICEA S-68-516 / NEMA WC-8
Flame-test referencesMSHA P-122 MSHA flame-resistance; UL 1581 vertical tray flame test
Portable power cable referenceUL 1650 Portable Power Cable
Other supplied referencesCSA approved; MSHA listed; RoHS compliant

State the required standard edition, approval scope, test report and documentation requirements in the enquiry.

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    Optional: attach a cable specification, drawing, data sheet or product image (PDF, DOC, DOCX, XLS, XLSX, CSV, JPG or PNG; maximum 10 MB).

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.