CABLES PARA MINERÍA Y TÚNELES TEBAOFLEX

NTSKCGECWOEU 1.8/3–3.6/6 kV Coal Cutter Chain Cable

Medium-voltage coal-cutter chain cable with double concentric control/PE conductors and closed-lay steel/copper wire protection.

Información del producto
Marca
TEBAOFLEX
Descripción general del producto

NTSKCGECWOEU is a medium-voltage coal-cutter chain cable for underground mobile mining equipment, coal-cutting machines, cable protection chains and trailing cable handlers. The supplied VDE datasheet specifies finely stranded tinned copper conductors, 3GI3 EPR insulation, cold-strippable semiconductive field control, double concentric control and PE wire elements, a GM1B inner sheath, closed-lay steel and copper wire protection and a red 5GM5 synthetic elastomer outer sheath. The technical tables cover 1.8/3 kV and 3.6/6 kV systems, with three-control and six-control arrangements and conductor configurations from 25 mm² through 240 mm². The source lists 90 °C conductor operation, 250 °C short-circuit temperature, fixed service from −40 °C to +90 °C and fully flexible service from −20 °C to +90 °C. Chain geometry, movement cycles, tensile path, bending radius, core functions, UEL notation and termination hardware must be checked against the machine drawing. Use the size table together with the machine duty cycle and installation layout; cable selection should be approved against the chain travel, support spacing and connector system. Request the required configuration, size, length and test documents from TEBAOFLEX before release.

Construcción

NTSKCGECWOEU chain-cable construction

This construction combines three main power cores with double concentric control and PE conductor elements. The cable uses a finely stranded tinned-copper conductor, 3GI3 EPR insulation, an inner GM1B sheath, closed-lay steel/copper wire armouring and a red 5GM5 elastomer outer sheath.

NTSKCGECWOEU cable cross-section showing three power cores, double concentric control and PE conductors, armour and red outer sheath
Supplied NTSKCGECWOEU cross-section showing the double-concentric control/PE and armoured coal-cutter cable construction.
Construction identified in the supplied VDE datasheet
ParámetroValor indicado en la fuente
Main conductorFinely stranded tinned copper conductor, class FS
Control / PE conductorDouble concentric control / PE wire spinning in the outer interstices
AislamientoCompuesto de caucho EPR tipo 3GI3
Control de campo eléctricoCold-strippable outer layer of semiconductive rubber compound
Identificación centralMain cores natural colour; control cores blue
vaina interiorVulcanized EPR rubber inner sheath, compound type GM1B
BlindajeClosed-lay spinning of steel / copper wires between inner and outer sheath
Vaina exteriorSynthetic elastomer compound type 5GM5, red

The chain-protection route and the double-concentric control/PE arrangement are the key ordering distinctions. Keep the source core notation in the RFQ and verify the termination hardware against the final cable drawing.

Aplicaciones

Applications for NTSKCGECWOEU

The source describes a power-supply connection cable for mobile equipment and machines in underground mining, including coal-cutting machines. It is intended for cable protection chains and cable handlers trailed behind the machine, where repeated movement and tensile forces must be absorbed.

Underground coal-mining equipment with a trailing power cable in a wet mine environment
Existing Media Library image illustrating underground coal-mining equipment; the actual chain, handler and termination must be confirmed for NTSKCGECWOEU.
  • Underground coal-cutting machines and other mobile mining equipment listed in the source
  • Cable protection chains and cable handlers trailed behind the machine
  • 1.8/3 kV and 3.6/6 kV systems with three- or six-control-core table options
  • Confirm chain geometry, movement cycle, tensile path, bend radius, core functions, terminations and protection interface before quotation

The supplied bending and tensile values describe the cable construction; they do not replace the machine-specific chain calculation or the approved installation drawing.

Especificaciones

NTSKCGECWOEU specifications

The supplied tables cover 1.8/3 kV and 3.6/6 kV versions, with either three or six control-core arrangements. “UEL” is retained exactly as the source designation; confirm its meaning and the final core schedule on the approved order drawing.

NTSKCGECWOEU electrical and mechanical characteristics
ParámetroValor indicado en la fuente
Tensión nominal1.8/3 kV; 3.6/6 kV
Maximum permissible AC operating voltage2.1/3.6 kV; 4.2/7.2 kV
Maximum permissible DC operating voltage2.7/5.4 kV; 5.4/10.8 kV
Voltaje de prueba de CA6 kV for 1.8/3 kV; 11 kV for 3.6/6 kV
AC test voltage — control cores2 KV
Temperatura máxima de funcionamiento del conductor90 °C
Temperatura máxima del conductor en cortocircuito250 °C
Temperatura de instalación fija−40 °C to +90 °C
Fully flexible operation temperature−20 °C to +90 °C
Carga de tracción máxima15 N/mm2
Radio de curvatura2.3 × D at maximum 5 N/mm² tensile load; S-type distance 20 × D
1.8/3 kV — three control cores
Cross-section / core arrangementDiámetro exterior del conductor (mm)OD min–max (mm)Peso (kg/km)Tensile (N)DC resistance (Ω/km)Capacitancia (µF/km)Inductancia (mH/km)Corriente (A)Short-circuit (kA)
3×25+3×(1.5ST+16/3)+UEL7.140.1–43.1310011250.7950.330.321313.58
3×35+3×(1.5ST+25/3)+UEL8.444.3–47.3397015750.5650.380.301625.01
3×50+3×(1.5ST+25/3)+UEL10.149.7–52.7490022500.3930.440.292027.15
3×70+3×(1.5ST+35/3)+UEL11.953.2–57.2602031500.2770.500.2725010.01
3×95+3×(1.5ST+50/3)+UEL1458.6–62.6745042750.2100.540.2730113.59
3×120+3×(1.5ST+70/3)+UEL15.562.9–66.9906054000.1640.580.2735217.16
3×150+3×(1.5ST+70/3)+UEL17.269–731082067500.1320.640.2640421.45
3×185+3×(1.5ST+95/3)+UEL19.173.2–77.21253083250.1080.700.2546126.46
3×240+3×(1.5ST+120/3)+UEL2280.7–85.715700108000.08170.790.2554034.32
3.6/6 kV — three control cores
Cross-section / core arrangementDiámetro exterior del conductor (mm)OD min–max (mm)Peso (kg/km)Tensile (N)DC resistance (Ω/km)Capacitancia (µF/km)Inductancia (mH/km)Corriente (A)Short-circuit (kA)
3×25+3×(1.5ST+16/3)+UEL7.145–48360011250.7950.340.331313.58
3×35+3×(1.5ST+25/3)+UEL8.448.3–51.3436015750.5650.380.311625.01
3×50+3×(1.5ST+25/3)+UEL10.151.4–55.4532022500.3930.430.302027.15
3×70+3×(1.5ST+35/3)+UEL11.956.7–60.7656031500.2770.490.2925010.01
3×95+3×(1.5ST+50/3)+UEL1461.2–65.2789042750.2100.550.2830113.59
3×120+3×(1.5ST+70/3)+UEL15.567.3–71.3978054000.1640.600.2735217.16
3×150+3×(1.5ST+70/3)+UEL17.271.7–75.71130067500.1320.640.2640421.45
3×185+3×(1.5ST+95/3)+UEL19.175.1–79.11279083250.1080.690.2546126.46
3×240+3×(1.5ST+120/3)+UEL2282.7–87.715900108000.08170.770.2554034.32
3.6/6 kV — six control cores
Cross-section / core arrangementDiámetro exterior del conductor (mm)OD min–max (mm)Peso (kg/km)Tensile (N)DC resistance (Ω/km)Capacitancia (µF/km)Inductancia (mH/km)Corriente (A)Short-circuit (kA)
3×35+3×(2×1.5ST+25/3)+UEL8.449–53462015750.5650.380.311625.01
3×50+3×(2×1.5ST+25/3)+UEL10.153.9–57.9555022500.3930.430.302027.15
3×70+3×(2×1.5ST+35/3)+UEL11.956.7–60.7676031500.2770.490.3925010.01
3×95+3×(2×1.5ST+50/3)+UEL1462–66790042750.2100.550.2830113.59
3×120+3×(2×1.5ST+70/3)+UEL15.567.3–71.3980054000.1640.600.2735217.16
3×150+3×(2×1.5ST+70/3)+UEL17.271–751110067500.1320.640.2640421.45
3×185+3×(2×1.5ST+95/3)+UEL19.175.1–79.11300083250.1080.690.2546126.46
3×240+3×(2×1.5ST+120/3)+UEL2282.7–87.716000108000.08170.770.2554034.32

Current carrying capacity is based on rubber cables laid on a surface at 30 °C ambient temperature. The source identifies manufacturer-specific article numbers as omitted.

Estándares

NTSKCGECWOEU standards and performance

The supplied datasheet lists the following cable standard, fire, oil and weather-performance references.

Standards, tests and approvals referenced for this product
ParámetroValor indicado en la fuente
Cable standardDIN VDE 0250-813
Fire performanceIEC 60332-1-2
Resistencia al aceiteIEC 60811-404
Resistencia a la intemperiePara uso en exteriores e interiores; resistente al ozono, a los rayos UV y a la humedad.
Current-table basisRubber cables laid on a surface at 30 °C ambient temperature

Request the required standard edition, inspection scope, test report and final cable marking with the order. No manufacturer-specific article numbers are reproduced in the public page.

Comparar por impuesto

Opciones de cable relacionadas

Compare estas opciones de cable según la combinación de servicios, el movimiento, la carga, el voltaje y los requisitos de transmisión.

Cotización basada en ingeniería

Solicite una recomendación y un presupuesto de cables.

Indique los servicios requeridos, la longitud del cable, la carga mecánica, el entorno, el tipo de terminación y la cantidad. Nuestro equipo revisará la solicitud antes de elaborar un presupuesto.

  • Incluya el nombre del producto o SKU, así como la longitud y la cantidad de cable requeridas.
  • Adjunte una especificación, un dibujo o una hoja de datos cuando esté disponible.

    Opcional: adjunte una especificación del cable, un dibujo, una hoja de datos o una imagen del producto (PDF, DOC, DOCX, XLS, XLSX, CSV, JPG o PNG; máximo 10 MB).

    Al enviar este formulario, usted acepta que TEBAOFLEX pueda utilizar la información de contacto y los archivos proporcionados para revisar y responder a su consulta. Los archivos se utilizan para la cotización y la comunicación técnica relacionada con su solicitud. Consulte nuestra política de privacidad para obtener información actualizada sobre el manejo y la retención de datos.

    * Campos obligatorios. Incluya el cable clave o los detalles de la aplicación para su revisión.