NTSKCGECWOEU 1.8/3–3.6/6 kV Coal Cutter Chain Cable
Medium-voltage coal-cutter chain cable with double concentric control/PE conductors and closed-lay steel/copper wire protection.
NTSKCGECWOEU is a medium-voltage coal-cutter chain cable for underground mobile mining equipment, coal-cutting machines, cable protection chains and trailing cable handlers. The supplied VDE datasheet specifies finely stranded tinned copper conductors, 3GI3 EPR insulation, cold-strippable semiconductive field control, double concentric control and PE wire elements, a GM1B inner sheath, closed-lay steel and copper wire protection and a red 5GM5 synthetic elastomer outer sheath. The technical tables cover 1.8/3 kV and 3.6/6 kV systems, with three-control and six-control arrangements and conductor configurations from 25 mm² through 240 mm². The source lists 90 °C conductor operation, 250 °C short-circuit temperature, fixed service from −40 °C to +90 °C and fully flexible service from −20 °C to +90 °C. Chain geometry, movement cycles, tensile path, bending radius, core functions, UEL notation and termination hardware must be checked against the machine drawing. Use the size table together with the machine duty cycle and installation layout; cable selection should be approved against the chain travel, support spacing and connector system. Request the required configuration, size, length and test documents from TEBAOFLEX before release.
NTSKCGECWOEU chain-cable construction
This construction combines three main power cores with double concentric control and PE conductor elements. The cable uses a finely stranded tinned-copper conductor, 3GI3 EPR insulation, an inner GM1B sheath, closed-lay steel/copper wire armouring and a red 5GM5 elastomer outer sheath.

| Parámetro | Valor indicado en la fuente |
|---|---|
| Main conductor | Finely stranded tinned copper conductor, class FS |
| Control / PE conductor | Double concentric control / PE wire spinning in the outer interstices |
| Aislamiento | Compuesto de caucho EPR tipo 3GI3 |
| Control de campo eléctrico | Cold-strippable outer layer of semiconductive rubber compound |
| Identificación central | Main cores natural colour; control cores blue |
| vaina interior | Vulcanized EPR rubber inner sheath, compound type GM1B |
| Blindaje | Closed-lay spinning of steel / copper wires between inner and outer sheath |
| Vaina exterior | Synthetic elastomer compound type 5GM5, red |
The chain-protection route and the double-concentric control/PE arrangement are the key ordering distinctions. Keep the source core notation in the RFQ and verify the termination hardware against the final cable drawing.
Applications for NTSKCGECWOEU
The source describes a power-supply connection cable for mobile equipment and machines in underground mining, including coal-cutting machines. It is intended for cable protection chains and cable handlers trailed behind the machine, where repeated movement and tensile forces must be absorbed.

- Underground coal-cutting machines and other mobile mining equipment listed in the source
- Cable protection chains and cable handlers trailed behind the machine
- 1.8/3 kV and 3.6/6 kV systems with three- or six-control-core table options
- Confirm chain geometry, movement cycle, tensile path, bend radius, core functions, terminations and protection interface before quotation
The supplied bending and tensile values describe the cable construction; they do not replace the machine-specific chain calculation or the approved installation drawing.
NTSKCGECWOEU specifications
The supplied tables cover 1.8/3 kV and 3.6/6 kV versions, with either three or six control-core arrangements. “UEL” is retained exactly as the source designation; confirm its meaning and the final core schedule on the approved order drawing.
| Parámetro | Valor indicado en la fuente |
|---|---|
| Tensión nominal | 1.8/3 kV; 3.6/6 kV |
| Maximum permissible AC operating voltage | 2.1/3.6 kV; 4.2/7.2 kV |
| Maximum permissible DC operating voltage | 2.7/5.4 kV; 5.4/10.8 kV |
| Voltaje de prueba de CA | 6 kV for 1.8/3 kV; 11 kV for 3.6/6 kV |
| AC test voltage — control cores | 2 KV |
| Temperatura máxima de funcionamiento del conductor | 90 °C |
| Temperatura máxima del conductor en cortocircuito | 250 °C |
| Temperatura de instalación fija | −40 °C to +90 °C |
| Fully flexible operation temperature | −20 °C to +90 °C |
| Carga de tracción máxima | 15 N/mm2 |
| Radio de curvatura | 2.3 × D at maximum 5 N/mm² tensile load; S-type distance 20 × D |
| Cross-section / core arrangement | Diámetro exterior del conductor (mm) | OD min–max (mm) | Peso (kg/km) | Tensile (N) | DC resistance (Ω/km) | Capacitancia (µF/km) | Inductancia (mH/km) | Corriente (A) | Short-circuit (kA) |
|---|---|---|---|---|---|---|---|---|---|
| 3×25+3×(1.5ST+16/3)+UEL | 7.1 | 40.1–43.1 | 3100 | 1125 | 0.795 | 0.33 | 0.32 | 131 | 3.58 |
| 3×35+3×(1.5ST+25/3)+UEL | 8.4 | 44.3–47.3 | 3970 | 1575 | 0.565 | 0.38 | 0.30 | 162 | 5.01 |
| 3×50+3×(1.5ST+25/3)+UEL | 10.1 | 49.7–52.7 | 4900 | 2250 | 0.393 | 0.44 | 0.29 | 202 | 7.15 |
| 3×70+3×(1.5ST+35/3)+UEL | 11.9 | 53.2–57.2 | 6020 | 3150 | 0.277 | 0.50 | 0.27 | 250 | 10.01 |
| 3×95+3×(1.5ST+50/3)+UEL | 14 | 58.6–62.6 | 7450 | 4275 | 0.210 | 0.54 | 0.27 | 301 | 13.59 |
| 3×120+3×(1.5ST+70/3)+UEL | 15.5 | 62.9–66.9 | 9060 | 5400 | 0.164 | 0.58 | 0.27 | 352 | 17.16 |
| 3×150+3×(1.5ST+70/3)+UEL | 17.2 | 69–73 | 10820 | 6750 | 0.132 | 0.64 | 0.26 | 404 | 21.45 |
| 3×185+3×(1.5ST+95/3)+UEL | 19.1 | 73.2–77.2 | 12530 | 8325 | 0.108 | 0.70 | 0.25 | 461 | 26.46 |
| 3×240+3×(1.5ST+120/3)+UEL | 22 | 80.7–85.7 | 15700 | 10800 | 0.0817 | 0.79 | 0.25 | 540 | 34.32 |
| Cross-section / core arrangement | Diámetro exterior del conductor (mm) | OD min–max (mm) | Peso (kg/km) | Tensile (N) | DC resistance (Ω/km) | Capacitancia (µF/km) | Inductancia (mH/km) | Corriente (A) | Short-circuit (kA) |
|---|---|---|---|---|---|---|---|---|---|
| 3×25+3×(1.5ST+16/3)+UEL | 7.1 | 45–48 | 3600 | 1125 | 0.795 | 0.34 | 0.33 | 131 | 3.58 |
| 3×35+3×(1.5ST+25/3)+UEL | 8.4 | 48.3–51.3 | 4360 | 1575 | 0.565 | 0.38 | 0.31 | 162 | 5.01 |
| 3×50+3×(1.5ST+25/3)+UEL | 10.1 | 51.4–55.4 | 5320 | 2250 | 0.393 | 0.43 | 0.30 | 202 | 7.15 |
| 3×70+3×(1.5ST+35/3)+UEL | 11.9 | 56.7–60.7 | 6560 | 3150 | 0.277 | 0.49 | 0.29 | 250 | 10.01 |
| 3×95+3×(1.5ST+50/3)+UEL | 14 | 61.2–65.2 | 7890 | 4275 | 0.210 | 0.55 | 0.28 | 301 | 13.59 |
| 3×120+3×(1.5ST+70/3)+UEL | 15.5 | 67.3–71.3 | 9780 | 5400 | 0.164 | 0.60 | 0.27 | 352 | 17.16 |
| 3×150+3×(1.5ST+70/3)+UEL | 17.2 | 71.7–75.7 | 11300 | 6750 | 0.132 | 0.64 | 0.26 | 404 | 21.45 |
| 3×185+3×(1.5ST+95/3)+UEL | 19.1 | 75.1–79.1 | 12790 | 8325 | 0.108 | 0.69 | 0.25 | 461 | 26.46 |
| 3×240+3×(1.5ST+120/3)+UEL | 22 | 82.7–87.7 | 15900 | 10800 | 0.0817 | 0.77 | 0.25 | 540 | 34.32 |
| Cross-section / core arrangement | Diámetro exterior del conductor (mm) | OD min–max (mm) | Peso (kg/km) | Tensile (N) | DC resistance (Ω/km) | Capacitancia (µF/km) | Inductancia (mH/km) | Corriente (A) | Short-circuit (kA) |
|---|---|---|---|---|---|---|---|---|---|
| 3×35+3×(2×1.5ST+25/3)+UEL | 8.4 | 49–53 | 4620 | 1575 | 0.565 | 0.38 | 0.31 | 162 | 5.01 |
| 3×50+3×(2×1.5ST+25/3)+UEL | 10.1 | 53.9–57.9 | 5550 | 2250 | 0.393 | 0.43 | 0.30 | 202 | 7.15 |
| 3×70+3×(2×1.5ST+35/3)+UEL | 11.9 | 56.7–60.7 | 6760 | 3150 | 0.277 | 0.49 | 0.39 | 250 | 10.01 |
| 3×95+3×(2×1.5ST+50/3)+UEL | 14 | 62–66 | 7900 | 4275 | 0.210 | 0.55 | 0.28 | 301 | 13.59 |
| 3×120+3×(2×1.5ST+70/3)+UEL | 15.5 | 67.3–71.3 | 9800 | 5400 | 0.164 | 0.60 | 0.27 | 352 | 17.16 |
| 3×150+3×(2×1.5ST+70/3)+UEL | 17.2 | 71–75 | 11100 | 6750 | 0.132 | 0.64 | 0.26 | 404 | 21.45 |
| 3×185+3×(2×1.5ST+95/3)+UEL | 19.1 | 75.1–79.1 | 13000 | 8325 | 0.108 | 0.69 | 0.25 | 461 | 26.46 |
| 3×240+3×(2×1.5ST+120/3)+UEL | 22 | 82.7–87.7 | 16000 | 10800 | 0.0817 | 0.77 | 0.25 | 540 | 34.32 |
Current carrying capacity is based on rubber cables laid on a surface at 30 °C ambient temperature. The source identifies manufacturer-specific article numbers as omitted.
NTSKCGECWOEU standards and performance
The supplied datasheet lists the following cable standard, fire, oil and weather-performance references.
| Parámetro | Valor indicado en la fuente |
|---|---|
| Cable standard | DIN VDE 0250-813 |
| Fire performance | IEC 60332-1-2 |
| Resistencia al aceite | IEC 60811-404 |
| Resistencia a la intemperie | Para uso en exteriores e interiores; resistente al ozono, a los rayos UV y a la humedad. |
| Current-table basis | Rubber cables laid on a surface at 30 °C ambient temperature |
Request the required standard edition, inspection scope, test report and final cable marking with the order. No manufacturer-specific article numbers are reproduced in the public page.
Opciones de cable relacionadas
Compare estas opciones de cable según la combinación de servicios, el movimiento, la carga, el voltaje y los requisitos de transmisión.
Cable de arrastre para cortadora de carbón NSSHKCGEOEU de 0,6/1 kV
Una opción de cable relacionada para una aplicación o perfil de trabajo diferente.
Ver productoCable de arrastre para minería de media tensión (N)TSKCGEWÖU de 3,6/6 kV
Para servicio de arrastre de 3,6/6 kV detrás de equipos móviles de minería.
Ver producto(N)TSCGECECWÖU Cable de enrollado para tuneladora de 8,7/15 kV y 12/20 kV
Una opción de cable relacionada para una aplicación o perfil de trabajo diferente.
Ver productoSolicite una recomendación y un presupuesto de cables.
Indique los servicios requeridos, la longitud del cable, la carga mecánica, el entorno, el tipo de terminación y la cantidad. Nuestro equipo revisará la solicitud antes de elaborar un presupuesto.
- Incluya el nombre del producto o SKU, así como la longitud y la cantidad de cable requeridas.
- Adjunte una especificación, un dibujo o una hoja de datos cuando esté disponible.