NTSKCGECWOEU 1.8/3–3.6/6 kV Coal Cutter Chain Cable
Medium-voltage coal-cutter chain cable with double concentric control/PE conductors and closed-lay steel/copper wire protection.
NTSKCGECWOEU is a medium-voltage coal-cutter chain cable for underground mobile mining equipment, coal-cutting machines, cable protection chains and trailing cable handlers. The supplied VDE datasheet specifies finely stranded tinned copper conductors, 3GI3 EPR insulation, cold-strippable semiconductive field control, double concentric control and PE wire elements, a GM1B inner sheath, closed-lay steel and copper wire protection and a red 5GM5 synthetic elastomer outer sheath. The technical tables cover 1.8/3 kV and 3.6/6 kV systems, with three-control and six-control arrangements and conductor configurations from 25 mm² through 240 mm². The source lists 90 °C conductor operation, 250 °C short-circuit temperature, fixed service from −40 °C to +90 °C and fully flexible service from −20 °C to +90 °C. Chain geometry, movement cycles, tensile path, bending radius, core functions, UEL notation and termination hardware must be checked against the machine drawing. Use the size table together with the machine duty cycle and installation layout; cable selection should be approved against the chain travel, support spacing and connector system. Request the required configuration, size, length and test documents from TEBAOFLEX before release.
NTSKCGECWOEU chain-cable construction
This construction combines three main power cores with double concentric control and PE conductor elements. The cable uses a finely stranded tinned-copper conductor, 3GI3 EPR insulation, an inner GM1B sheath, closed-lay steel/copper wire armouring and a red 5GM5 elastomer outer sheath.

| Parâmetro | Valor indicado na fonte |
|---|---|
| Main conductor | Finely stranded tinned copper conductor, class FS |
| Control / PE conductor | Double concentric control / PE wire spinning in the outer interstices |
| Isolamento | Composto de borracha EPR tipo 3GI3 |
| Controle de campo elétrico | Cold-strippable outer layer of semiconductive rubber compound |
| Identificação central | Main cores natural colour; control cores blue |
| bainha interna | Vulcanized EPR rubber inner sheath, compound type GM1B |
| Blindagem | Closed-lay spinning of steel / copper wires between inner and outer sheath |
| Bainha externa | Synthetic elastomer compound type 5GM5, red |
The chain-protection route and the double-concentric control/PE arrangement are the key ordering distinctions. Keep the source core notation in the RFQ and verify the termination hardware against the final cable drawing.
Applications for NTSKCGECWOEU
The source describes a power-supply connection cable for mobile equipment and machines in underground mining, including coal-cutting machines. It is intended for cable protection chains and cable handlers trailed behind the machine, where repeated movement and tensile forces must be absorbed.

- Underground coal-cutting machines and other mobile mining equipment listed in the source
- Cable protection chains and cable handlers trailed behind the machine
- 1.8/3 kV and 3.6/6 kV systems with three- or six-control-core table options
- Confirm chain geometry, movement cycle, tensile path, bend radius, core functions, terminations and protection interface before quotation
The supplied bending and tensile values describe the cable construction; they do not replace the machine-specific chain calculation or the approved installation drawing.
NTSKCGECWOEU specifications
The supplied tables cover 1.8/3 kV and 3.6/6 kV versions, with either three or six control-core arrangements. “UEL” is retained exactly as the source designation; confirm its meaning and the final core schedule on the approved order drawing.
| Parâmetro | Valor indicado na fonte |
|---|---|
| Tensão nominal | 1.8/3 kV; 3.6/6 kV |
| Maximum permissible AC operating voltage | 2.1/3.6 kV; 4.2/7.2 kV |
| Maximum permissible DC operating voltage | 2.7/5.4 kV; 5.4/10.8 kV |
| tensão de teste CA | 6 kV for 1.8/3 kV; 11 kV for 3.6/6 kV |
| AC test voltage — control cores | 2 kV |
| temperatura máxima de operação do condutor | 90 °C |
| temperatura máxima do condutor em curto-circuito | 250 °C |
| Temperatura de instalação fixa | −40 °C to +90 °C |
| Fully flexible operation temperature | −20 °C to +90 °C |
| carga máxima de tração | 15 N/mm² |
| Raio de curvatura | 2.3 × D at maximum 5 N/mm² tensile load; S-type distance 20 × D |
| Cross-section / core arrangement | Diâmetro externo do condutor (mm) | OD min–max (mm) | Peso (kg/km) | Tensile (N) | DC resistance (Ω/km) | Capacitância (µF/km) | Indutância (mH/km) | Corrente (A) | Short-circuit (kA) |
|---|---|---|---|---|---|---|---|---|---|
| 3×25+3×(1.5ST+16/3)+UEL | 7.1 | 40.1–43.1 | 3100 | 1125 | 0.795 | 0.33 | 0.32 | 131 | 3.58 |
| 3×35+3×(1.5ST+25/3)+UEL | 8.4 | 44.3–47.3 | 3970 | 1575 | 0.565 | 0.38 | 0.30 | 162 | 5.01 |
| 3×50+3×(1.5ST+25/3)+UEL | 10.1 | 49.7–52.7 | 4900 | 2250 | 0.393 | 0.44 | 0.29 | 202 | 7.15 |
| 3×70+3×(1.5ST+35/3)+UEL | 11.9 | 53.2–57.2 | 6020 | 3150 | 0.277 | 0.50 | 0.27 | 250 | 10.01 |
| 3×95+3×(1.5ST+50/3)+UEL | 14 | 58.6–62.6 | 7450 | 4275 | 0.210 | 0.54 | 0.27 | 301 | 13.59 |
| 3×120+3×(1.5ST+70/3)+UEL | 15.5 | 62.9–66.9 | 9060 | 5400 | 0.164 | 0.58 | 0.27 | 352 | 17.16 |
| 3×150+3×(1.5ST+70/3)+UEL | 17.2 | 69–73 | 10820 | 6750 | 0.132 | 0.64 | 0.26 | 404 | 21.45 |
| 3×185+3×(1.5ST+95/3)+UEL | 19.1 | 73.2–77.2 | 12530 | 8325 | 0.108 | 0.70 | 0.25 | 461 | 26.46 |
| 3×240+3×(1.5ST+120/3)+UEL | 22 | 80.7–85.7 | 15700 | 10800 | 0.0817 | 0.79 | 0.25 | 540 | 34.32 |
| Cross-section / core arrangement | Diâmetro externo do condutor (mm) | OD min–max (mm) | Peso (kg/km) | Tensile (N) | DC resistance (Ω/km) | Capacitância (µF/km) | Indutância (mH/km) | Corrente (A) | Short-circuit (kA) |
|---|---|---|---|---|---|---|---|---|---|
| 3×25+3×(1.5ST+16/3)+UEL | 7.1 | 45–48 | 3600 | 1125 | 0.795 | 0.34 | 0.33 | 131 | 3.58 |
| 3×35+3×(1.5ST+25/3)+UEL | 8.4 | 48.3–51.3 | 4360 | 1575 | 0.565 | 0.38 | 0.31 | 162 | 5.01 |
| 3×50+3×(1.5ST+25/3)+UEL | 10.1 | 51.4–55.4 | 5320 | 2250 | 0.393 | 0.43 | 0.30 | 202 | 7.15 |
| 3×70+3×(1.5ST+35/3)+UEL | 11.9 | 56.7–60.7 | 6560 | 3150 | 0.277 | 0.49 | 0.29 | 250 | 10.01 |
| 3×95+3×(1.5ST+50/3)+UEL | 14 | 61.2–65.2 | 7890 | 4275 | 0.210 | 0.55 | 0.28 | 301 | 13.59 |
| 3×120+3×(1.5ST+70/3)+UEL | 15.5 | 67.3–71.3 | 9780 | 5400 | 0.164 | 0.60 | 0.27 | 352 | 17.16 |
| 3×150+3×(1.5ST+70/3)+UEL | 17.2 | 71.7–75.7 | 11300 | 6750 | 0.132 | 0.64 | 0.26 | 404 | 21.45 |
| 3×185+3×(1.5ST+95/3)+UEL | 19.1 | 75.1–79.1 | 12790 | 8325 | 0.108 | 0.69 | 0.25 | 461 | 26.46 |
| 3×240+3×(1.5ST+120/3)+UEL | 22 | 82.7–87.7 | 15900 | 10800 | 0.0817 | 0.77 | 0.25 | 540 | 34.32 |
| Cross-section / core arrangement | Diâmetro externo do condutor (mm) | OD min–max (mm) | Peso (kg/km) | Tensile (N) | DC resistance (Ω/km) | Capacitância (µF/km) | Indutância (mH/km) | Corrente (A) | Short-circuit (kA) |
|---|---|---|---|---|---|---|---|---|---|
| 3×35+3×(2×1.5ST+25/3)+UEL | 8.4 | 49–53 | 4620 | 1575 | 0.565 | 0.38 | 0.31 | 162 | 5.01 |
| 3×50+3×(2×1.5ST+25/3)+UEL | 10.1 | 53.9–57.9 | 5550 | 2250 | 0.393 | 0.43 | 0.30 | 202 | 7.15 |
| 3×70+3×(2×1.5ST+35/3)+UEL | 11.9 | 56.7–60.7 | 6760 | 3150 | 0.277 | 0.49 | 0.39 | 250 | 10.01 |
| 3×95+3×(2×1.5ST+50/3)+UEL | 14 | 62–66 | 7900 | 4275 | 0.210 | 0.55 | 0.28 | 301 | 13.59 |
| 3×120+3×(2×1.5ST+70/3)+UEL | 15.5 | 67.3–71.3 | 9800 | 5400 | 0.164 | 0.60 | 0.27 | 352 | 17.16 |
| 3×150+3×(2×1.5ST+70/3)+UEL | 17.2 | 71–75 | 11100 | 6750 | 0.132 | 0.64 | 0.26 | 404 | 21.45 |
| 3×185+3×(2×1.5ST+95/3)+UEL | 19.1 | 75.1–79.1 | 13000 | 8325 | 0.108 | 0.69 | 0.25 | 461 | 26.46 |
| 3×240+3×(2×1.5ST+120/3)+UEL | 22 | 82.7–87.7 | 16000 | 10800 | 0.0817 | 0.77 | 0.25 | 540 | 34.32 |
Current carrying capacity is based on rubber cables laid on a surface at 30 °C ambient temperature. The source identifies manufacturer-specific article numbers as omitted.
NTSKCGECWOEU standards and performance
The supplied datasheet lists the following cable standard, fire, oil and weather-performance references.
| Parâmetro | Valor indicado na fonte |
|---|---|
| Cable standard | DIN VDE 0250-813 |
| Fire performance | IEC 60332-1-2 |
| Resistência ao óleo | IEC 60811-404 |
| Resistência às condições atmosféricas | Outdoor and indoor use; resistant to ozone and moisture |
| Current-table basis | Rubber cables laid on a surface at 30 °C ambient temperature |
Request the required standard edition, inspection scope, test report and final cable marking with the order. No manufacturer-specific article numbers are reproduced in the public page.
Opções de cabos relacionadas
Compare estas opções de cabos por combinação de serviços, movimentação, carga, tensão e requisito de transmissão.
Cabo de arrasto para cortador de carvão NSSHKCGEOEU 0,6/1kV
Uma opção de cabo relacionada para uma aplicação ou perfil de serviço diferente.
Ver produto(N)TSKCGEWÖU Cabo de arrasto de média tensão para mineração 3,6/6kV
Para serviço de reboque de 3,6/6 kV atrás de equipamentos móveis de mineração.
Ver produto(N)TSCGECECWÖU 8,7/15kV 12/20kV Cabo de enrolamento TBM
Uma opção de cabo relacionada para uma aplicação ou perfil de serviço diferente.
Ver produtoSolicite uma recomendação e orçamento de cabos.
Envie-nos as especificações dos serviços necessários, comprimento do cabo, capacidade mecânica, ambiente, tipo de terminação e quantidade. Nossa equipe analisará a solicitação antes de enviar um orçamento.
- Inclua o nome do produto ou o código SKU, além do comprimento e da quantidade de cabos necessários.
- Anexe uma especificação, desenho ou ficha técnica, quando disponíveis.