UL 5390 is a UL-certified mica-glass wire rated 550°C and 300 V AC for internal equipment wiring. Its high-temperature insulation system combines mica with a treated fiberglass braid around the conductor.
- Voltaje: 300 V AC
- Temperatura: 550°C
- Aislamiento / cubierta: mica composite with treated fiberglass braid
- Selección de tamaño: 24–4 AWG style range; table: 24–14 AWG
- Certificación: AWM con certificación UL; UL 758
UL 5390 wire selection
UL 5390 is a UL-certified mica-glass wire rated 550°C and 300 V AC for internal equipment wiring. Its high-temperature insulation system combines mica with a treated fiberglass braid around the conductor.
The dimension table gives six stranded nickel-coated copper configurations from 24 AWG to 14 AWG. Every row identifies UL 5390 with the wire size and includes strand count, finished diameter, approximate weight and minimum bend radius. A separate thickness schedule covers the wider 24–4 AWG style range. This keeps dimensioned constructions distinct from the broader conductor sizes permitted by the style.
For a hot-zone equipment lead, confirm the temperature at the wire and termination, the required operating voltage and the space available for a supported route. The 550°C rating does not increase the 300 V voltage rating. The optional stainless-steel braid shield is a separate construction choice and should be stated on the order if required; it is not included in the unshielded dimension table.
Consulte la pestaña Especificaciones para ver las tablas de modelos y calibres. Explore la gama de cables de alta temperatura for related constructions. Compare the 450°C MGT mica-glass wire and the separate 600 V UL 5359 construction.
Construcción
UL 1056 utiliza el sistema de conductor y aislamiento que se muestra a continuación. El diagrama indica el orden de las capas; seleccione la construcción del conductor y la cubierta que figuran en la especificación del calibre requerido.

| Componente | Detalle de construcción |
|---|---|
| Conductor | Stranded 27% nickel-coated copper in the dimensioned construction |
| Aislamiento | Mica-glass composite |
| Cubierta exterior | Treated fiberglass braid |
| Optional style construction | 304 stainless-steel braid shield |
Aplicaciones
UL 5390 is intended for internal equipment wiring requiring a 550°C mica-glass construction at 300 V AC. Review the hot-zone route, terminal materials and mechanical protection together before selecting the conductor size.

UL 5390 replacement selection
Para solicitar un repuesto, envíe el marcado del cable existente y el plano de conexión del equipo. Así se podrán comparar el conductor, el aislamiento y la disposición de los terminales.
Especificaciones
| Parámetro | Especificación |
|---|---|
| Estilo UL | UL 5390 |
| Tensión nominal | 300 V AC |
| Clasificación de temperatura | 550°C |
| Aislamiento / revestimiento | mica composite with treated fiberglass braid |
| Rango de calibres del conductor | 24–4 AWG style range; table: 24–14 AWG |
| Construcción | Single conductor with non-extruded insulation |
Unshielded 550°C, 300 V construction dimensions for selection. Values are nominal; the quotation drawing defines the supplied construction.
| Modelo y calibre del conductor | Hebras | OD (mm) | OD (in) | Peso (kg/km) | Weight (lb/1000 ft) | Radio de curvatura mín. (in) |
|---|---|---|---|---|---|---|
| UL 5390 24 AWG | 7 | 2.03 | 0.080 | 7.22 | 5 | 0.64 |
| UL 5390 22 AWG | 7 | 2.21 | 0.087 | 8.86 | 6 | 0.70 |
| UL 5390 20 AWG | 10 | 2.34 | 0.092 | 10.37 | 7 | 0.74 |
| UL 5390 18 AWG | 16 | 2.64 | 0.104 | 15.30 | 10 | 0.83 |
| UL 5390 16 AWG | 26 | 3.05 | 0.120 | 22.49 | 15 | 0.96 |
| UL 5390 14 AWG | 41 | 3.30 | 0.130 | 29.69 | 20 | 1.04 |
Style construction thicknesses are shown in mils; 1 mil = 0.0254 mm. Nominal finished dimensions are listed separately.
| Model and conductor group | Minimum average composite wall (mils) | Minimum point wall (mils) |
|---|---|---|
| UL 5390 24–12 AWG | 25 | 22 |
| UL 5390 11–4 AWG | 33 | 30 |
Selección de la construcción especificada
Specify UL 5390 with AWG, conductor material, 300 V AC duty and any shield requirement. Use the selected row for nominal OD, weight and bend radius, and request a drawing for sizes beyond the dimensioned table.
Normas
TEBAOFLEX UL 5390 wire is UL-certified appliance wiring material.
| Artículo | Requisito o referencia |
|---|---|
| Certificación | AWM con certificación UL |
| Designación del estilo | UL 5390 |
| Norma de construcción | UL 758 — Material de cableado para aparatos |
| Clasificación de inflamabilidad del estilo | Llama horizontal |
Indique el estilo UL, el calibre del conductor y los valores de tensión y temperatura en la especificación de compra. Incluya en la consulta la identificación del producto y los documentos de certificación requeridos.
Solicite una recomendación y un presupuesto de cables.
Indique los servicios requeridos, la longitud del cable, la carga mecánica, el entorno, el tipo de terminación y la cantidad. Nuestro equipo revisará la solicitud antes de elaborar un presupuesto.
- Incluya el nombre del producto o SKU, así como la longitud y la cantidad de cable requeridas.
- Adjunte una especificación, un dibujo o una hoja de datos cuando esté disponible.