Solicita un presupuesto
CABLES PARA MINERÍA Y TÚNELES TEBAOFLEX

Type SHD-PCG 2 kV Mining Power Cable

Type SHD-PCG cable is a 2 kV three-conductor portable mining power cable for the stated longwall-shearer duty.

  • Core system: three shielded power, three control and one grounding conductor
  • Aislamiento: EPR
  • Chaqueta: reinforced extra-heavy-duty black CPE
  • Radio de curvatura mínimo: 6 × OD
  • Maximum operating temperature: +90°C

Request a quote with the Type SHD-PCG size, machine connection and route details.

Información del producto
Marca
TEBAOFLEX
Descripción general del producto

Type SHD-PCG 2 kV three-conductor portable power cable

TEBAOFLEX Type SHD-PCG is a 2 kV heavy-duty portable mining power cable for the stated use on longwall shearers. The supplied construction provides three shielded power conductors, three unshielded control conductors and one grounding conductor, supporting the power, control and grounding functions required by this equipment arrangement. EPR insulation, conductor shielding, a tinned copper/textile braid and a reinforced CPE jacket form the stated Type SHD-PCG cable design.

The Type SHD-PCG data supplied for this page includes nominal constructions from 3×1/0 through 3×4/0, with stated ampacities from 211 A to 321 A. These values are based on a 90°C conductor temperature and 40°C ambient air temperature under ICEA S-75-381. Actual cable selection must also account for the longwall machine, cable route, reeling or trailing duty, installation conditions, protection settings, voltage drop and site requirements.

  • Stated application: longwall shearers requiring three shielded power, three unshielded control and one grounding conductor.
  • Tensión nominal: 2 kV; 5 kV and 8 kV are stated as available on request.
  • Radio de curvatura mínimo: 6 × diámetro total.
  • Maximum operating temperature: +90°C.

Ver el Gama de cables para minería y túneles for related cable types. Send the required Type SHD-PCG size, equipment connection, route, length and documentation requirements for a technical quotation.

Construcción

Type SHD-PCG construction

The supplied Type SHD-PCG construction combines three shielded power conductors, a three-conductor control group and a central grounding conductor within a reinforced CPE jacket.

Type SHD-PCG mining power cable cutaway showing power, control and grounding conductors within a reinforced black CPE jacket
Type SHD-PCG cable construction view; final core arrangement follows the approved order drawing.
Elemento constructivoSupplied Type SHD-PCG reference
ConductoresStranded annealed tinned copper conductor
AislamientoEPR
Escudo aislanteNon-conducting tape plus tinned copper/textile braid
Control group (3 conductors)Tinned copper conductor, EPR insulation and thermosetting sheath; black, white and red insulation colours
Conductor de puesta a tierraTinned copper conductor located at the centre of the cable
VainaReinforced extra-heavy-duty chlorinated polyethylene (CPE), black
OptionsCSP, PCP, NBR or PVC jacket materials on request; two-layer jacket with reinforcing fibre between layers available as an option
Aplicaciones

Aplicaciones

Type SHD-PCG heavy-duty cables are supplied for use on longwall shearers where three shielded power conductors, three unshielded control conductors and a grounding conductor are required. The supplied rating is 2 kV; 5 kV and 8 kV are available on request.

Underground longwall mining equipment and trailing cable, illustrating Type SHD-PCG portable power cable application
Underground longwall mining environment illustrating the stated Type SHD-PCG application.

Selection checks

  • Confirm power-core, control-core and grounding-conductor functions against the approved longwall equipment wiring schedule.
  • Check route length, movement, bending, mechanical protection, terminations and site conditions before choosing a Type SHD-PCG construction.
  • Use the supplied 6 × OD minimum bend radius and +90°C maximum operating temperature within the project installation assessment.
  • State the required voltage, cable size, jacket option, length, marking and test-documentation requirements with the enquiry.

TEBAOFLEX can review the stated Type SHD-PCG configuration against the project’s equipment and cable-routing information before quotation.

Especificaciones

Type SHD-PCG specifications

The following nominal Type SHD-PCG data is transcribed from the supplied product information. Ampacity is based on a 90°C conductor temperature and 40°C ambient air temperature, per ICEA S-75-381.

ConstrucciónNo. of strandsGrounding conductor sizeControl conductor sizeNominal insulation thicknessNominal sheath thicknessNominal overall diameterPeso nominalAmpacity
3×1/02593 AWG/kcmil8 AWG/kcmil2.0 mm (0.08 in)5.2 mm (0.205 in)52.1 mm (2.05 in)4,602 kg/km (3,092 lbs/kft)211 A
3×2/03292 AWG/kcmil8 AWG/kcmil2.0 mm (0.08 in)5.6 mm (0.220 in)57.1 mm (2.25 in)5,503 kg/km (3,698 lbs/kft)243 A
3×3/04131 AWG/kcmil8 AWG/kcmil2.0 mm (0.08 in)5.6 mm (0.220 in)58.9 mm (2.32 in)6,392 kg/km (4,295 lbs/kft)279 A
3×4/05321/0 AWG/kcmil8 AWG/kcmil2.0 mm (0.08 in)6.3 mm (0.250 in)66.5 mm (2.62 in)7,612 kg/km (5,115 lbs/kft)321 A
Tensión nominal2 kV; 5 kV and 8 kV available on request
Radio de curvatura mínimo6 × OD
Maximum operating temperature+90°C
Estándares

Normas

The supplied Type SHD-PCG information names the following standards.

Primary standardICEA S-75-381 / NEMA WC 58
Referencias del directorASTM B 172; ASTM B 33
Canadian referenceCAN/CSA-C22.2 No. 96

Include the required standard edition, project test scope and documentation requirements in the enquiry.

Comparar por impuesto

Opciones de cable relacionadas

Compare estas opciones de cable según la combinación de servicios, el movimiento, la carga, el voltaje y los requisitos de transmisión.

Cotización basada en ingeniería

Solicite una recomendación y un presupuesto de cables.

Indique los servicios requeridos, la longitud del cable, la carga mecánica, el entorno, el tipo de terminación y la cantidad. Nuestro equipo revisará la solicitud antes de elaborar un presupuesto.

  • Incluya el nombre del producto o SKU, así como la longitud y la cantidad de cable requeridas.
  • Adjunte una especificación, un dibujo o una hoja de datos cuando esté disponible.

    Opcional: adjunte una especificación del cable, un dibujo, una hoja de datos o una imagen del producto (PDF, DOC, DOCX, XLS, XLSX, CSV, JPG o PNG; máximo 10 MB).

    Al enviar este formulario, usted acepta que TEBAOFLEX pueda utilizar la información de contacto y los archivos proporcionados para revisar y responder a su consulta. Los archivos se utilizan para la cotización y la comunicación técnica relacionada con su solicitud. Consulte nuestra política de privacidad para obtener información actualizada sobre el manejo y la retención de datos.

    * Campos obligatorios. Incluya el cable clave o los detalles de la aplicación para su revisión.