Get a Quote
MINING & TUNNELING CABLES TEBAOFLEX

Type SHD-PCG 2 kV Mining Power Cable

Type SHD-PCG cable is a 2 kV three-conductor portable mining power cable for the stated longwall-shearer duty.

  • Core system: three shielded power, three control and one grounding conductor
  • Insulation: EPR
  • Jacket: reinforced extra-heavy-duty black CPE
  • Minimum bending radius: 6 × OD
  • Maximum operating temperature: +90°C

Request a quote with the Type SHD-PCG size, machine connection and route details.

Product information
Brand
TEBAOFLEX
Product overview

Type SHD-PCG 2 kV three-conductor portable power cable

TEBAOFLEX Type SHD-PCG is a 2 kV heavy-duty portable mining power cable for the stated use on longwall shearers. The supplied construction provides three shielded power conductors, three unshielded control conductors and one grounding conductor, supporting the power, control and grounding functions required by this equipment arrangement. EPR insulation, conductor shielding, a tinned copper/textile braid and a reinforced CPE jacket form the stated Type SHD-PCG cable design.

The Type SHD-PCG data supplied for this page includes nominal constructions from 3×1/0 through 3×4/0, with stated ampacities from 211 A to 321 A. These values are based on a 90°C conductor temperature and 40°C ambient air temperature under ICEA S-75-381. Actual cable selection must also account for the longwall machine, cable route, reeling or trailing duty, installation conditions, protection settings, voltage drop and site requirements.

  • Stated application: longwall shearers requiring three shielded power, three unshielded control and one grounding conductor.
  • Rated voltage: 2 kV; 5 kV and 8 kV are stated as available on request.
  • Minimum bending radius: 6 × overall diameter.
  • Maximum operating temperature: +90°C.

See the mining and tunneling cable range for related cable types. Send the required Type SHD-PCG size, equipment connection, route, length and documentation requirements for a technical quotation.

Construction

Type SHD-PCG construction

The supplied Type SHD-PCG construction combines three shielded power conductors, a three-conductor control group and a central grounding conductor within a reinforced CPE jacket.

Type SHD-PCG mining power cable cutaway showing power, control and grounding conductors within a reinforced black CPE jacket
Type SHD-PCG cable construction view; final core arrangement follows the approved order drawing.
Construction elementSupplied Type SHD-PCG reference
ConductorsStranded annealed tinned copper conductor
InsulationEPR
Insulation shieldNon-conducting tape plus tinned copper/textile braid
Control group (3 conductors)Tinned copper conductor, EPR insulation and thermosetting sheath; black, white and red insulation colours
Grounding conductorTinned copper conductor located at the centre of the cable
SheathReinforced extra-heavy-duty chlorinated polyethylene (CPE), black
OptionsCSP, PCP, NBR or PVC jacket materials on request; two-layer jacket with reinforcing fibre between layers available as an option
Applications

Applications

Type SHD-PCG heavy-duty cables are supplied for use on longwall shearers where three shielded power conductors, three unshielded control conductors and a grounding conductor are required. The supplied rating is 2 kV; 5 kV and 8 kV are available on request.

Underground longwall mining equipment and trailing cable, illustrating Type SHD-PCG portable power cable application
Underground longwall mining environment illustrating the stated Type SHD-PCG application.

Selection checks

  • Confirm power-core, control-core and grounding-conductor functions against the approved longwall equipment wiring schedule.
  • Check route length, movement, bending, mechanical protection, terminations and site conditions before choosing a Type SHD-PCG construction.
  • Use the supplied 6 × OD minimum bend radius and +90°C maximum operating temperature within the project installation assessment.
  • State the required voltage, cable size, jacket option, length, marking and test-documentation requirements with the enquiry.

TEBAOFLEX can review the stated Type SHD-PCG configuration against the project’s equipment and cable-routing information before quotation.

Specifications

Type SHD-PCG specifications

The following nominal Type SHD-PCG data is transcribed from the supplied product information. Ampacity is based on a 90°C conductor temperature and 40°C ambient air temperature, per ICEA S-75-381.

ConstructionNo. of strandsGrounding conductor sizeControl conductor sizeNominal insulation thicknessNominal sheath thicknessNominal overall diameterNominal weightAmpacity
3×1/02593 AWG/kcmil8 AWG/kcmil2.0 mm (0.08 in)5.2 mm (0.205 in)52.1 mm (2.05 in)4,602 kg/km (3,092 lbs/kft)211 A
3×2/03292 AWG/kcmil8 AWG/kcmil2.0 mm (0.08 in)5.6 mm (0.220 in)57.1 mm (2.25 in)5,503 kg/km (3,698 lbs/kft)243 A
3×3/04131 AWG/kcmil8 AWG/kcmil2.0 mm (0.08 in)5.6 mm (0.220 in)58.9 mm (2.32 in)6,392 kg/km (4,295 lbs/kft)279 A
3×4/05321/0 AWG/kcmil8 AWG/kcmil2.0 mm (0.08 in)6.3 mm (0.250 in)66.5 mm (2.62 in)7,612 kg/km (5,115 lbs/kft)321 A
Rated voltage2 kV; 5 kV and 8 kV available on request
Minimum bending radius6 × OD
Maximum operating temperature+90°C
Standards

Standards

The supplied Type SHD-PCG information names the following standards.

Primary standardICEA S-75-381 / NEMA WC 58
Conductor referencesASTM B 172; ASTM B 33
Canadian referenceCAN/CSA-C22.2 No. 96

Include the required standard edition, project test scope and documentation requirements in the enquiry.

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    Optional: attach a cable specification, drawing, data sheet or product image (PDF, DOC, DOCX, XLS, XLSX, CSV, JPG or PNG; maximum 10 MB).

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.