Solicite um orçamento
CABOS PARA MINERAÇÃO E ESCAVAÇÃO DE TÚNEIS TEBAOFLEX

Type SHD-PCG 2 kV Mining Power Cable

Type SHD-PCG cable is a 2 kV three-conductor portable mining power cable for the stated longwall-shearer duty.

  • Core system: three shielded power, three control and one grounding conductor
  • Isolamento: EPR
  • Jaqueta: reinforced extra-heavy-duty black CPE
  • Raio de curvatura mínimo: 6 × OD
  • Maximum operating temperature: +90°C

Request a quote with the Type SHD-PCG size, machine connection and route details.

Informações sobre o produto
Marca
TEBAOFLEX
Visão geral do produto

Type SHD-PCG 2 kV three-conductor portable power cable

TEBAOFLEX Type SHD-PCG is a 2 kV heavy-duty portable mining power cable for the stated use on longwall shearers. The supplied construction provides three shielded power conductors, three unshielded control conductors and one grounding conductor, supporting the power, control and grounding functions required by this equipment arrangement. EPR insulation, conductor shielding, a tinned copper/textile braid and a reinforced CPE jacket form the stated Type SHD-PCG cable design.

The Type SHD-PCG data supplied for this page includes nominal constructions from 3×1/0 through 3×4/0, with stated ampacities from 211 A to 321 A. These values are based on a 90°C conductor temperature and 40°C ambient air temperature under ICEA S-75-381. Actual cable selection must also account for the longwall machine, cable route, reeling or trailing duty, installation conditions, protection settings, voltage drop and site requirements.

  • Stated application: longwall shearers requiring three shielded power, three unshielded control and one grounding conductor.
  • Tensão nominal: 2 kV; 5 kV and 8 kV are stated as available on request.
  • Raio de curvatura mínimo: 6 vezes o diâmetro total.
  • Maximum operating temperature: +90°C.

Veja o gama de cabos para mineração e tunelamento for related cable types. Send the required Type SHD-PCG size, equipment connection, route, length and documentation requirements for a technical quotation.

Construção

Type SHD-PCG construction

The supplied Type SHD-PCG construction combines three shielded power conductors, a three-conductor control group and a central grounding conductor within a reinforced CPE jacket.

Type SHD-PCG mining power cable cutaway showing power, control and grounding conductors within a reinforced black CPE jacket
Type SHD-PCG cable construction view; final core arrangement follows the approved order drawing.
Elemento de construçãoSupplied Type SHD-PCG reference
CondutoresStranded annealed tinned copper conductor
IsolamentoEPR
Escudo de isolamentoNon-conducting tape plus tinned copper/textile braid
Control group (3 conductors)Tinned copper conductor, EPR insulation and thermosetting sheath; black, white and red insulation colours
Condutor de aterramentoTinned copper conductor located at the centre of the cable
BainhaReinforced extra-heavy-duty chlorinated polyethylene (CPE), black
OptionsCSP, PCP, NBR or PVC jacket materials on request; two-layer jacket with reinforcing fibre between layers available as an option
Aplicações

Aplicações

Type SHD-PCG heavy-duty cables are supplied for use on longwall shearers where three shielded power conductors, three unshielded control conductors and a grounding conductor are required. The supplied rating is 2 kV; 5 kV and 8 kV are available on request.

Underground longwall mining equipment and trailing cable, illustrating Type SHD-PCG portable power cable application
Underground longwall mining environment illustrating the stated Type SHD-PCG application.

Selection checks

  • Confirm power-core, control-core and grounding-conductor functions against the approved longwall equipment wiring schedule.
  • Check route length, movement, bending, mechanical protection, terminations and site conditions before choosing a Type SHD-PCG construction.
  • Use the supplied 6 × OD minimum bend radius and +90°C maximum operating temperature within the project installation assessment.
  • State the required voltage, cable size, jacket option, length, marking and test-documentation requirements with the enquiry.

TEBAOFLEX can review the stated Type SHD-PCG configuration against the project’s equipment and cable-routing information before quotation.

Especificações

Type SHD-PCG specifications

The following nominal Type SHD-PCG data is transcribed from the supplied product information. Ampacity is based on a 90°C conductor temperature and 40°C ambient air temperature, per ICEA S-75-381.

ConstruçãoNo. of strandsGrounding conductor sizeControl conductor sizeNominal insulation thicknessNominal sheath thicknessNominal overall diameterPeso nominalAmpacidade
3×1/02593 AWG/kcmil8 AWG/kcmil2.0 mm (0.08 in)5.2 mm (0.205 in)52.1 mm (2.05 in)4,602 kg/km (3,092 lbs/kft)211 A
3×2/03292 AWG/kcmil8 AWG/kcmil2.0 mm (0.08 in)5.6 mm (0.220 in)57.1 mm (2.25 in)5,503 kg/km (3,698 lbs/kft)243 A
3×3/04131 AWG/kcmil8 AWG/kcmil2.0 mm (0.08 in)5.6 mm (0.220 in)58.9 mm (2.32 in)6,392 kg/km (4,295 lbs/kft)279 A
3×4/05321/0 AWG/kcmil8 AWG/kcmil2.0 mm (0.08 in)6.3 mm (0.250 in)66.5 mm (2.62 in)7,612 kg/km (5,115 lbs/kft)321 A
Tensão nominal2 kV; 5 kV and 8 kV available on request
Raio de curvatura mínimo6 × OD
Maximum operating temperature+90°C
Padrões

Normas

The supplied Type SHD-PCG information names the following standards.

Primary standardICEA S-75-381 / NEMA WC 58
Referências do condutorASTM B 172; ASTM B 33
Canadian referenceCAN/CSA-C22.2 No. 96

Include the required standard edition, project test scope and documentation requirements in the enquiry.

Comparar por dever

Opções de cabos relacionadas

Compare estas opções de cabos por combinação de serviços, movimentação, carga, tensão e requisito de transmissão.

Cotação elaborada por engenheiros

Solicite uma recomendação e orçamento de cabos.

Envie-nos as especificações dos serviços necessários, comprimento do cabo, capacidade mecânica, ambiente, tipo de terminação e quantidade. Nossa equipe analisará a solicitação antes de enviar um orçamento.

  • Inclua o nome do produto ou o código SKU, além do comprimento e da quantidade de cabos necessários.
  • Anexe uma especificação, desenho ou ficha técnica, quando disponíveis.

    Opcional: anexe uma especificação do cabo, desenho, ficha técnica ou imagem do produto (PDF, DOC, DOCX, XLS, XLSX, CSV, JPG ou PNG; máximo de 10 MB).

    Ao enviar este formulário, você concorda que a TEBAOFLEX pode usar as informações de contato e os arquivos fornecidos para analisar e responder à sua solicitação. Os arquivos são usados para orçamentos e comunicação técnica relacionados à sua solicitação. Consulte nossa política de privacidade. política de Privacidade Para obter informações atuais sobre o tratamento e a retenção de dados.

    * Campos obrigatórios. Inclua os detalhes principais do cabo ou da aplicação para análise.