Type 245 Flexible Rubber Mining Cable 1.1–6.6 kV

Type 245 mining cable is a flexible rubber cable family for 1.1 kV, 3.3 kV and 6.6 kV longwall shearer, continuous-miner and peripheral longwall cable service. Its supplied construction combines flexible stranded tinned annealed copper, EPR insulation, semiconductive screening, central extensible pilots, interstitial earth conductors, open-weave reinforcement and a heavy-duty PCP sheath.

  • Voltage variants: Type 245.1 — 1.1 kV; Type 245.3 — 3.3 kV; Type 245.6 — 6.6 kV
  • Conducteur : flexible stranded tinned annealed copper
  • Isolation: Composé EPR
  • Screening: semiconductive conductor/insulation screens as specified by voltage variant, plus semiconductive PCP overall core screen
  • Monitoring and earth: three central extensible pilots and interstitial earth conductors
  • Gaine: heavy-duty PCP, black; CPE/CSP available on request
  • Température: +90 °C maximum continuous operating temperature; −25 °C minimum installation temperature
  • Standard: AS/NZS 1802; supplied flame-performance reference C1

Send the equipment, voltage variant, conductor area, cable length, route and documentation requirements for a technical quotation.

Informations sur le produit
Marque
Modèle / construction
Présentation du produit

Type 245 mining cable for longwall and continuous-miner service

Ce Type 245 mining cable is a flexible rubber cable family listed in the supplied datasheet for longwall shearers, continuous miners and peripheral longwall cable service. The family is organized by voltage and conductor area so a buyer can start with the machine supply requirement: Type 245.1 covers 1.1 kV, Type 245.3 covers 3.3 kV, and Type 245.6 covers 6.6 kV. The same page keeps those variants together while preserving their separate dimensional data.

The cable combines flexible tinned-copper conductors, EPR insulation, semiconductive screening, central extensible pilot conductors, interstitial earth conductors, open-weave reinforcement and a heavy-duty PCP sheath. The pilot arrangement is relevant where the cable system requires earth-continuity monitoring and control circuits, as stated in the source application note. See the gamme de câbles pour l'exploitation minière et le creusement de tunnels for adjacent cable families.

  • Choisir par : voltage variant, conductor area and the machine’s cable-service requirement.
  • Confirmez avant de commander : existing cable marking, route, length, drum or guide arrangement, terminations and required documents.
  • Important boundary: the supplied datasheet does not state a minimum bending radius, permitted tensile load or travel speed, so those values must be confirmed for the actual installation.
Construction

Type 245 mining cable construction

The Type 245 construction uses a flexible power-core arrangement with semiconductive layers, earth-continuity and control elements, textile reinforcement and a heavy-duty rubber sheath. The conductor screen is specified for cables rated 3.3 kV and above; the source does not state that screen for the 1.1 kV variant.

Type 245 cable cross-section showing power cores, pilot cores, earth conductors and reinforcement
Supplied Type 245 cross-section illustrating the power-core, pilot, earth and reinforcement arrangement.

Layer arrangement

Élément de constructionSource-listed construction
ConducteurCuivre étamé recuit souple à brins toronnés
Écran du conducteurSemi-conductive compound for cables rated 3.3 kV and above
IsolationComposé EPR
Écran d'isolationSemi-conductive elastomer
Séparateur de berceauSemiconductive PCP
Central extensible pilotcuivre étamé souple multibrins recouvert d'EPR
Overall core screenSemiconductive PCP filling and covering
Interstitial earth conductorSemi-conductive PCP-covered flexible stranded tinned copper
Reinforcing braidOpen-weave yarns
GaineHeavy-duty PCP sheath; CPE/CSP sheath available upon request

The supplied product image shows the black outer sheath, visible braid and exposed core arrangement. Final cable termination and the connection of pilot and earth functions must follow the equipment and protection design.

Applications

Type 245 mining cable applications

The supplied datasheet identifies Type 245 for longwall shearer cable service and also for continuous miners and peripheral longwall cable service. Its three central pilots are stated to support earth-continuity monitoring and control circuits.

  • Longwall shearers: select the voltage variant and conductor area required by the machine supply.
  • Continuous miners: confirm the existing cable marking, core functions and protection-system interface before cross-referencing.
  • Peripheral longwall service: confirm route length, handling method, guide or drum arrangement and cable quantity.
  • Mobile mine cable routes: the datasheet gives application and temperature limits but does not provide a minimum bend radius, tensile load or travel speed; obtain those values for the actual route before release.

For a quotation, provide the equipment nameplate or existing cable marking, voltage, conductor area, required length, installation route, terminations, inspection documents and any project-specific standard or marking requirement. Do not treat a Type 245 size-only match as proof of mechanical interchangeability.

Caractéristiques

Type 245 mining cable specifications

The following values are transcribed from the supplied Type 245 datasheet. The dimensional tables are separated by voltage variant because the insulation, screen and available conductor-area ranges differ. Confirm the final size, route and document requirements before quotation.

PropriétéValeur indiquée dans la source
ModèleType 245 flexible rubber mining cable
Tension nominale1.1 kV Type 245.1; 3.3 kV Type 245.3; 6.6 kV Type 245.6
température de fonctionnement continue maximale+90 °C
Minimum installation temperature−25 °C
Couleur du fourreauNoir
Comportement au feuC1
Installation conditionsLongwall shearer, continuous miner and peripheral longwall cable service

How to use the dimensional data

Use the voltage variant first, then check conductor area, nominal outer diameter and mass against the machine interface, cable supports and handling equipment. The source does not state current capacity, minimum bending radius, tensile load or travel speed; those items require project confirmation.

Type 245.1 — 1.1 kV dimensions and mass

Voltage variantNoyauxArea (mm²)Conductor strandInsul. (mm)Core screen strandScreen (mm²)Pilot strandPilot cover (mm)Sheath (mm)Cable Dia. (mm)Mass (kg/100m)
Type 245.1 — 1.1 kV316133/0.402.069/0.251.828/0.250.84.142.6235
Type 245.1 — 1.1 kV325259/0.361.691/0.251.828/0.250.84.243.4269
Type 245.1 — 1.1 kV335287/0.401.6140/0.251.428/0.250.84.445.6315
Type 245.1 — 1.1 kV350703/0.301.7120/0.301.028/0.250.84.848.4390
Type 245.1 — 1.1 kV370988/0.301.8180/0.301.028/0.250.85.153.9501
Type 245.1 — 1.1 kV3951332/0.302.0150/0.301.028/0.250.85.660.4630
Type 245.1 — 1.1 kV31201702/0.302.1195/0.301.228/0.250.86.065.5765
Type 245.1 — 1.1 kV31502146/0.302.3235/0.301.228/0.250.86.370.5915

Type 245.3 — 3.3 kV dimensions and mass

Voltage variantNoyauxArea (mm²)Conductor strandInsul. (mm)Core screen strandScreen (mm²)Pilot strandPilot cover (mm)Sheath (mm)Cable Dia. (mm)Mass (kg/100m)
Type 245.3 — 3.3 kV325259/0.363.091/0.251.528/0.250.85.251.1338
Type 245.3 — 3.3 kV335287/0.403.0140/0.251.028/0.250.85.454.5398
Type 245.3 — 3.3 kV350703/0.303.0120/0.301.028/0.250.85.756.8490
Type 245.3 — 3.3 kV370988/0.303.0180/0.301.228/0.250.86.061.2592
Type 245.3 — 3.3 kV3951332/0.303.0235/0.301.228/0.250.86.466.6739
Type 245.3 — 3.3 kV31201702/0.303.0300/0.301.228/0.250.86.771.0870
Type 245.3 — 3.3 kV31502146/0.303.0375/0.301.228/0.250.87.075.21028

Type 245.6 — 6.6 kV dimensions and mass

Voltage variantNoyauxArea (mm²)Conductor strandInsul. (mm)Core screen strandScreen (mm²)Pilot strandPilot cover (mm)Sheath (mm)Cable Dia. (mm)Mass (kg/100m)
Type 245.6 — 6.6 kV350703/0.305.0120/0.301.428/0.250.86.767.2635
Type 245.6 — 6.6 kV370988/0.305.0180/0.301.428/0.250.87.071.7755
Type 245.6 — 6.6 kV3951332/0.305.0235/0.301.428/0.250.87.477.1905
Type 245.6 — 6.6 kV31201702/0.305.0300/0.301.428/0.250.87.781.31050
Type 245.6 — 6.6 kV31502146/0.305.0375/0.301.428/0.250.88.085.81210
Normes

Type 245 mining cable standards and references

The supplied product datasheet lists the following standard and reference information. The wording is retained as source-listed information and is not expanded into a separate certificate or approval claim.

ObjetRéférence indiquée par la source
Norme du produitAS/NZS 1802
Comportement au feuC1
Voltage designationsType 245.1 — 1.1 kV; Type 245.3 — 3.3 kV; Type 245.6 — 6.6 kV

For the RFQ, state the required AS/NZS 1802 documentation, inspection or test-report scope, cable marking, voltage variant and destination requirements.

Comparer par fonction

Options de câbles associées

Comparez ces options de câbles en fonction de la combinaison de services, du mouvement, de la charge, de la tension et des exigences de transmission.

devis basé sur l'ingénierie

Demandez une recommandation et un devis pour un câble.

Veuillez nous indiquer les services requis, la longueur du câble, les contraintes mécaniques, l'environnement, le type de terminaison et la quantité. Notre équipe examinera votre demande avant de vous établir un devis.

  • Veuillez inclure le nom du produit ou son SKU, ainsi que la longueur et la quantité de câble requises.
  • Joignez une fiche technique, un dessin ou une fiche de spécifications si disponible.

    Facultatif : joindre une spécification de câble, un dessin, une fiche technique ou une image du produit (PDF, DOC, DOCX, XLS, XLSX, CSV, JPG ou PNG ; maximum 10 Mo).

    En soumettant ce formulaire, vous acceptez que TEBAOFLEX utilise vos coordonnées et les fichiers fournis pour examiner votre demande et y répondre. Les fichiers servent à l'établissement du devis et aux échanges techniques relatifs à votre demande. Consultez notre politique de confidentialité. politique de confidentialité pour obtenir des informations à jour sur le traitement et la conservation des données.