Solicite um orçamento
CABOS PARA MINERAÇÃO E ESCAVAÇÃO DE TÚNEIS TEBAOFLEX

NSHXOEU-O / NSHXOEU-J 0.6/1 kV Flexible Mining Cable

Combined O single-core and J multi-core 0.6/1 kV flexible mining cable for tunnel, open-cast, quarry and industrial routes.

Informações sobre o produto
Marca
TEBAOFLEX
Visão geral do produto

NSHXOEU-O / NSHXOEU-J is one combined 0.6/1 kV flexible mining-cable page covering the O single-core and J multi-core configurations. The supplied VDE datasheet positions the family for underground mining, tunnel building, open-cast mining, quarries, construction sites and industrial routes with medium mechanical stress. It describes finely stranded tinned copper conductors to DIN VDE 0295 and IEC 60228, 3GI3 EPR insulation, core identification by colour or black numbering, a GM1B inner sheath for multi-core cables and a yellow 5GM3 outer sheath. The source lists 3 kV main-core testing, 90 °C conductor operation, 250 °C short-circuit temperature, fixed service from −40 °C to +90 °C, fully flexible service from −25 °C to +90 °C and a maximum water temperature of 40 °C. O entries include 300 mm² and 400 mm² single cores; J entries cover the supplied three-, four- and five-core arrangements. The combined page prevents duplicate O/J records while keeping the technical distinction visible for purchasing and engineering review. Confirm whether O or J is required, together with water condition, site classification, conductor size, route, bending radius, current derating and termination before ordering.

Construção

NSHXOEU-O and NSHXOEU-J construction

The supplied NSHXOEU family covers an O single-core configuration and J multi-core configurations. Both use finely stranded tinned copper, 3GI3 EPR insulation and a 5GM3 yellow outer sheath; the source specifies a GM1B inner sheath for multi-core construction and identifies the core arrangement by core count.

NSHXOEU-O and NSHXOEU-J cable cross-section showing flexible copper conductors, EPR insulation and rubber sheath
Supplied NSHXOEU-O / NSHXOEU-J cross-section for the combined O/J product page.
Construction identified in the supplied VDE datasheet
ParâmetroValor indicado na fonte
CondutorTinned copper, finely stranded class 5 according to DIN VDE 0295 / IEC 60228
IsolamentoComposto de borracha EPR tipo 3GI3
Identificação centralUp to 5 cores coloured according to DIN VDE 0293-308; from 6 cores light with black numbers
bainha internaEPR rubber compound type GM1B; not for single-core cables
Bainha externaEVA-based rubber compound type 5GM3, yellow
Page structureO and J configurations remain on one canonical product page

The O/J distinction changes the core arrangement and ordering data. Do not select a single-core O entry where the equipment requires the multi-core J protective-conductor arrangement.

Aplicações

Applications for NSHXOEU-O / NSHXOEU-J

The supplied application covers flexible use and fixed installation in underground mining, tunnel building, open-cast mining, quarries, construction sites and similar duties with medium mechanical stress. It lists indoor and outdoor use, plus use in explosion-hazard areas subject to the applicable site requirements.

NSHXOEU mining cable application with open-pit equipment and a cable reel
Existing Media Library image illustrating open-pit/mobile mining equipment and cable handling; confirm the actual NSHXOEU-O or J route and site requirements.
  • Underground, tunnelling, open-cast, quarry and construction-site routes with medium mechanical stress
  • O single-core configurations and J multi-core configurations listed in the supplied data
  • Indoor and outdoor installations, with the source also listing explosion-hazard-area use subject to site rules
  • Permanent waste-water service up to 40 °C is listed; groundwater and seawater use is more limited and must be confirmed
  • Confirm conductor size, core function, fixed/flexible mode, current derating, water conditions and termination before quotation

The source provides a maximum water temperature but does not make every water environment interchangeable. Send the actual fluid, depth/route and movement conditions with the RFQ.

Especificações

NSHXOEU-O and NSHXOEU-J specifications

O and J configurations are kept on one canonical page. The supplied tables retain the separate single-core O and multi-core J entries so the buyer can compare construction, diameter, weight and electrical values without creating duplicate size pages.

NSHXOEU electrical and mechanical characteristics
ParâmetroValor indicado na fonte
Rated voltage U₀/U0,6/1 kV
Maximum permissible AC operating voltage0,7/1,2 kV
Maximum permissible DC operating voltage0,9/1,8 kV
AC test voltage — main cores3 kV / 5 min
AC test voltage — control cores2 kV
temperatura máxima de operação do condutor+90 °C
Temperatura máxima do condutor em curto-circuito+250 °C
Fixed ambient temperature−40 °C to +90 °C
Fully flexible ambient temperature−25 °C to +90 °C
Maximum water temperature+40 °C
Maximum tensile load on conductor15 N/mm²
Raio de curvatura mínimoDe acordo com a norma DIN VDE 0298 Parte 3
NSHXOEU-O / NSHXOEU-J dimensions and mechanical data
Type / core arrangementConductor diameter max. (mm)Outer diameter min. (mm)Outer diameter max. (mm)Fixed bending radius min. (mm)Peso (kg/km)Força de tração máxima (N)
NSHXOEU-O 1 × 30022.934.536.814733304500
NSHXOEU-O 1 × 40026.238.540.516242106000
NSHXOEU-J 3 × 2.521213.654250113
NSHXOEU-J 3 × 50/258.838.141.116429303000
NSHXOEU-J 3 × 70/3510.642.345.318137904200
NSHXOEU-J 3 × 95/5012.148.252.220951705700
NSHXOEU-J 3 × 120/7014.254.658.623464827200
NSHXOEU-J 3 × 150/7016.1606425675689000
NSHXOEU-J 3 × 185/9517.967.371.3285932811100
NSHXOEU-J 4 × 2.5214.21664310150
NSHXOEU-J 5 × 1.51.612.714.357250113
NSHXOEU-J 5 × 2.5214.716.767380188
NSHXOEU-J 5 × 42.416.518.574500300
NSHXOEU-J 5 × 62.918.620.682660450
NSHXOEU-J 5 × 103.922.524.5981000750
NSHXOEU-J 5 × 165.426.729.711914401200
NSHXOEU-J 5 × 256.331.734.713921101875
NSHXOEU-J 5 × 357.536.939.916027432625
NSHXOEU-O / NSHXOEU-J electrical data
Type / core arrangementConductor resistance at 20 °C max. (Ω/km)Operating capacitance nom. (µF/km)Inductance nom. (mH/km)Current carrying capacity (A)Short-circuit current conductor (kA)
NSHXOEU-O 1 × 3000.06540.760.2384342.9
NSHXOEU-O 1 × 4000.04950.760.24102457.2
NSHXOEU-J 3 × 2.58.210.230.32300.36
NSHXOEU-J 3 × 50/250.3930.50.252027.15
NSHXOEU-J 3 × 70/350.2770.590.2425010.01
NSHXOEU-J 3 × 95/500.210.60.2430113.59
NSHXOEU-J 3 × 120/700.1640.690.2335217.16
NSHXOEU-J 3 × 150/700.1320.70.2340421.45
NSHXOEU-J 3 × 185/950.1080.710.2346126.46
NSHXOEU-J 4 × 2.58.210.230.32300.36
NSHXOEU-J 5 × 1.513.70.220.33230.21
NSHXOEU-J 5 × 2.58.210.230.32300.36
NSHXOEU-J 5 × 45.090.260.31410.57
NSHXOEU-J 5 × 63.390.30.29530.86
NSHXOEU-J 5 × 101.950.320.28741.43
NSHXOEU-J 5 × 161.240.420.26992.29
NSHXOEU-J 5 × 250.7950.420.261313.58
NSHXOEU-J 5 × 350.5650.490.251625.01

Nominal current carrying capacity is for rubber cables laid on a surface at 30 °C ambient temperature; apply the applicable technical appendix derating factors.

Padrões

NSHXOEU-O / NSHXOEU-J standards and tests

The page keeps O and J under one product intent while preserving the supplied construction and test references.

Standards, tests and approvals referenced for this product
ParâmetroValor indicado na fonte
ConstruçãoCom base na norma DIN VDE 0250 Parte 812
Propagação da chamaDIN EN 60332-1-2
Resistance to oilDIN EN 60811-2-1
Water resistanceEN 50525-2-21
Source-listed installationIndoor and outdoor use; site-specific requirements apply

Confirm the required standard edition, site classification, water-duty documentation and final O/J marking with the quotation request.

Comparar por dever

Opções de cabos relacionadas

Compare estas opções de cabos por combinação de serviços, movimentação, carga, tensão e requisito de transmissão.

Cotação elaborada por engenheiros

Solicite uma recomendação e orçamento de cabos.

Envie-nos as especificações dos serviços necessários, comprimento do cabo, capacidade mecânica, ambiente, tipo de terminação e quantidade. Nossa equipe analisará a solicitação antes de enviar um orçamento.

  • Inclua o nome do produto ou o código SKU, além do comprimento e da quantidade de cabos necessários.
  • Anexe uma especificação, desenho ou ficha técnica, quando disponíveis.

    Opcional: anexe uma especificação do cabo, desenho, ficha técnica ou imagem do produto (PDF, DOC, DOCX, XLS, XLSX, CSV, JPG ou PNG; máximo de 10 MB).

    Ao enviar este formulário, você concorda que a TEBAOFLEX pode usar as informações de contato e os arquivos fornecidos para analisar e responder à sua solicitação. Os arquivos são usados para orçamentos e comunicação técnica relacionados à sua solicitação. Consulte nossa política de privacidade. política de Privacidade Para obter informações atuais sobre o tratamento e a retenção de dados.

    * Campos obrigatórios. Inclua os detalhes principais do cabo ou da aplicação para análise.