UL 3580 Silicone Motor Lead Wire, 150°C 1000V
UL 3580 is a UL-certified silicone motor lead wire rated 150°C and 1000 V AC. It is intended for motor leads and internal appliance or electronic equipment wiring where the lead is protected from mechanical abuse.
- Spannung: 1000 V AC
- Temperatur: 150°C
- Isolierung / Umhüllung: extruded silicone rubber
- Größenauswahl: 26 AWG–500 kcmil style range; table: 26–6 AWG
- Zertifizierung: UL-zertifiziertes AWM; UL 758
UL 3580 wire selection
UL 3580 is a UL-certified silicone motor lead wire rated 150°C and 1000 V AC. It is intended for motor leads and internal appliance or electronic equipment wiring where the lead is protected from mechanical abuse.
The detailed size table covers 26–6 AWG. Nominal silicone thickness is 1.20 mm in the 26–10 AWG rows and 1.58 mm in the 8–6 AWG rows. Conductor stranding and finished diameter are listed with each model-size combination to help check motor terminal entries, connection boxes and protective sleeves. A separate insulation schedule explains the larger conductor groups within the style range.
For a motor connection, allow space for the finished wire rather than selecting the entry around the bare conductor size. The listed construction uses a bend radius of 10 times its finished diameter. Check the temperature near the winding exit and at the connection hardware, because the 150°C wire rating must be compatible with the rest of the assembly.
Modell- und Größentabellen finden Sie auf der Registerkarte „Spezifikationen“. Sehen Sie sich die Kategorie Hochtemperaturkabel-Sortiment for related constructions. Compare UL 3644 for a different 1 kV wall schedule and the Familie der Silikon-Anschlussleitungen for lower-voltage options.
Aufbau
UL 3580 uses the following conductor and insulation system. The diagram illustrates the layer sequence; select the conductor construction and covering shown in the required size specification.

| Bestandteil | Aufbaudetail |
|---|---|
| Leiter | Solid or stranded copper; dimensioned examples are stranded |
| Isolierung | Extrudierter Silikonkautschuk |
Anwendungen
UL 3580 is used as motor lead wire and for internal appliance or electronic equipment wiring. Route and support the lead to prevent rubbing or mechanical damage at the winding exit and terminal enclosure.

UL 3580 replacement selection
Geben Sie bei Ersatzanfragen die Kennzeichnung der vorhandenen Leitung und den Anschlussplan des Geräts an, damit Leiter, Isolierung und Klemmenanordnung abgeglichen werden können.
Technische Daten
| Parameter | Spezifikation |
|---|---|
| UL-Stil | UL 3580 |
| Nennspannung | 1000 V AC |
| Temperaturbemessung | 150°C |
| Isolierung / Umhüllung | extruded silicone rubber |
| Abgedeckter Leitergrößenbereich | 26 AWG–500 kcmil style range; table: 26–6 AWG |
| Bending radius for listed construction | 10 × finished OD |
Nominal dimensions follow the listed conductor constructions. Confirm the agreed finished-diameter drawing for tight-clearance assemblies.
| Modell und Leitergröße | Litzenanzahl (Anz./mm) | Nominal silicone wall (mm) | Nenn-Außendurchmesser / Toleranz (mm) |
|---|---|---|---|
| UL 3580 6 AWG | 259/0.254 | 1.58 | 7.89 ±0.10 |
| UL 3580 8 AWG | 161/0.254 | 1.58 | 6.88 ±0.10 |
| UL 3580 10 AWG | 105/0.254 | 1.20 | 5.41 ±0.10 |
| UL 3580 12 AWG | 65/0.254 | 1.20 | 4.77 ±0.10 |
| UL 3580 14 AWG | 41/0.254 | 1.20 | 4.28 ±0.10 |
| UL 3580 16 AWG | 26/0.254 | 1.20 | 3.90 ±0.10 |
| UL 3580 18 AWG | 34/0.18 | 1.20 | 3.62 ±0.10 |
| UL 3580 20 AWG | 21/0.18 | 1.20 | 3.36 ±0.10 |
| UL 3580 22 AWG | 17/0.16 | 1.20 | 3.17 ±0.10 |
| UL 3580 24 AWG | 11/0.16 | 1.20 | 3.02 ±0.10 |
| UL 3580 26 AWG | 7/0.16 | 1.20 | 2.89 ±0.10 |
Style construction thicknesses are shown in mils; 1 mil = 0.0254 mm. Nominal finished dimensions are listed separately.
| Model and conductor group | Minimum average silicone wall (mils) | Minimum point wall (mils) |
|---|---|---|
| UL 3580 26–9 AWG | 45 | 40 |
| UL 3580 8–2 AWG | 60 | 54 |
| UL 3580 1–4/0 AWG | 80 | 72 |
| UL 3580 250–500 kcmil | 95 | 86 |
Auswahl der spezifizierten Ausführung
Specify UL 3580 with AWG or kcmil, stranding, required OD and connection temperature. For a size outside the dimension table, use the insulation schedule as a starting point and request the corresponding drawing.
Normen
TEBAOFLEX UL 3580 wire is UL-certified appliance wiring material.
| Merkmal | Anforderung oder Referenz |
|---|---|
| Zertifizierung | UL-zertifiziertes AWM |
| Stilbezeichnung | UL 3580 |
| Konstruktionsnorm | UL 758 — Verdrahtungsmaterial für Geräte |
| Flammklassifizierung des Stils | Horizontale Flammprüfung |
Geben Sie in der Einkaufsspezifikation den UL-Stil, die Leitergröße sowie Spannungs- und Temperaturklasse an. Fügen Sie der Anfrage die erforderliche Produktkennzeichnung und Zertifizierungsunterlagen bei.
Kabelempfehlung und Angebot anfordern
Senden Sie die benötigten Funktionen, Kabellänge, mechanische Beanspruchung, Umgebung, Anschlussausführung und Menge. Unser Team prüft die Anwendung vor der Angebotserstellung.
- Geben Sie den Produktnamen oder die SKU sowie die benötigte Kabellänge und Menge an.
- Fügen Sie nach Möglichkeit eine Spezifikation, Zeichnung oder ein Datenblatt bei.