UL 3580 Silicone Motor Lead Wire, 150°C 1000V

UL 3580 is a UL-certified silicone motor lead wire rated 150°C and 1000 V AC. It is intended for motor leads and internal appliance or electronic equipment wiring where the lead is protected from mechanical abuse.

  • Voltaje: 1000 V AC
  • Temperatura: 150°C
  • Aislamiento / cubierta: extruded silicone rubber
  • Selección de tamaño: 26 AWG–500 kcmil style range; table: 26–6 AWG
  • Certificación: AWM con certificación UL; UL 758
Información del producto
Descripción general del producto

UL 3580 wire selection

UL 3580 is a UL-certified silicone motor lead wire rated 150°C and 1000 V AC. It is intended for motor leads and internal appliance or electronic equipment wiring where the lead is protected from mechanical abuse.

The detailed size table covers 26–6 AWG. Nominal silicone thickness is 1.20 mm in the 26–10 AWG rows and 1.58 mm in the 8–6 AWG rows. Conductor stranding and finished diameter are listed with each model-size combination to help check motor terminal entries, connection boxes and protective sleeves. A separate insulation schedule explains the larger conductor groups within the style range.

For a motor connection, allow space for the finished wire rather than selecting the entry around the bare conductor size. The listed construction uses a bend radius of 10 times its finished diameter. Check the temperature near the winding exit and at the connection hardware, because the 150°C wire rating must be compatible with the rest of the assembly.

Consulte la pestaña Especificaciones para ver las tablas de modelos y calibres. Explore la gama de cables de alta temperatura for related constructions. Compare UL 3644 for a different 1 kV wall schedule and the cables de conexión de silicona for lower-voltage options.

Construcción

Construcción

UL 1056 utiliza el sistema de conductor y aislamiento que se muestra a continuación. El diagrama indica el orden de las capas; seleccione la construcción del conductor y la cubierta que figuran en la especificación del calibre requerido.

Illustrative UL 3580 single-core conductor and insulation construction cutaway
Illustrative UL 3580 construction; layer dimensions are not to scale.
UL 3580 construction layers
ComponenteDetalle de construcción
ConductorSolid or stranded copper; dimensioned examples are stranded
AislamientoCaucho de silicona extruido
Aplicaciones

Aplicaciones

UL 3580 is used as motor lead wire and for internal appliance or electronic equipment wiring. Route and support the lead to prevent rubbing or mechanical damage at the winding exit and terminal enclosure.

Illustrative UL 3580 insulated lead routed inside industrial equipment
Illustrative UL 3580 equipment application; shown as an installation concept.

UL 3580 replacement selection

Para solicitar un repuesto, envíe el marcado del cable existente y el plano de conexión del equipo. Así se podrán comparar el conductor, el aislamiento y la disposición de los terminales.

Especificaciones

Especificaciones

UL 3580 technical data
ParámetroEspecificación
Estilo ULUL 3580
Tensión nominal1000 V AC
Clasificación de temperatura150°C
Aislamiento / revestimientoextruded silicone rubber
Rango de calibres del conductor26 AWG–500 kcmil style range; table: 26–6 AWG
Bending radius for listed construction10 × finished OD

Nominal dimensions follow the listed conductor constructions. Confirm the agreed finished-diameter drawing for tight-clearance assemblies.

UL 3580 size and dimension table
Modelo y calibre del conductorHilos del conductor (n.º/mm)Nominal silicone wall (mm)Diámetro exterior nominal / tolerancia (mm)
UL 3580 6 AWG259/0.2541.587.89 ±0.10
UL 3580 8 AWG161/0.2541.586.88 ±0.10
UL 3580 10 AWG105/0.2541.205.41 ±0.10
UL 3580 12 AWG65/0.2541.204.77 ±0.10
UL 3580 14 AWG41/0.2541.204.28 ±0.10
UL 3580 16 AWG26/0.2541.203.90 ±0.10
UL 3580 18 AWG34/0.181.203.62 ±0.10
UL 3580 20 AWG21/0.181.203.36 ±0.10
UL 3580 22 AWG17/0.161.203.17 ±0.10
UL 3580 24 AWG11/0.161.203.02 ±0.10
UL 3580 26 AWG7/0.161.202.89 ±0.10

Style construction thicknesses are shown in mils; 1 mil = 0.0254 mm. Nominal finished dimensions are listed separately.

UL 3580 insulation thickness by conductor size
Model and conductor groupMinimum average silicone wall (mils)Minimum point wall (mils)
UL 3580 26–9 AWG4540
UL 3580 8–2 AWG6054
UL 3580 1–4/0 AWG8072
UL 3580 250–500 kcmil9586

Selección de la construcción especificada

Specify UL 3580 with AWG or kcmil, stranding, required OD and connection temperature. For a size outside the dimension table, use the insulation schedule as a starting point and request the corresponding drawing.

Estándares

Normas

TEBAOFLEX UL 3580 wire is UL-certified appliance wiring material.

UL 3580 certification and standards
ArtículoRequisito o referencia
CertificaciónAWM con certificación UL
Designación del estiloUL 3580
Norma de construcciónUL 758 — Material de cableado para aparatos
Clasificación de inflamabilidad del estiloLlama horizontal

Indique el estilo UL, el calibre del conductor y los valores de tensión y temperatura en la especificación de compra. Incluya en la consulta la identificación del producto y los documentos de certificación requeridos.

Cotización basada en ingeniería

Solicite una recomendación y un presupuesto de cables.

Indique los servicios requeridos, la longitud del cable, la carga mecánica, el entorno, el tipo de terminación y la cantidad. Nuestro equipo revisará la solicitud antes de elaborar un presupuesto.

  • Incluya el nombre del producto o SKU, así como la longitud y la cantidad de cable requeridas.
  • Adjunte una especificación, un dibujo o una hoja de datos cuando esté disponible.

    Al enviar este formulario, acepta que TEBAOFLEX utilice los datos de contacto y los archivos proporcionados para revisar y responder a su consulta. Los archivos se utilizan para elaborar la cotización y para la comunicación técnica relacionada con su solicitud. Consulte nuestra política de privacidad para obtener información actualizada sobre el manejo y la retención de datos.

    * Campos obligatorios. Incluya los datos clave del cable o de la aplicación para su revisión.