UL 3580 Silicone Motor Lead Wire, 150°C 1000V
UL 3580 is a UL-certified silicone motor lead wire rated 150°C and 1000 V AC. It is intended for motor leads and internal appliance or electronic equipment wiring where the lead is protected from mechanical abuse.
- Напряжение: 1000 V AC
- Температура: 150°C
- Изоляция / покрытие: extruded silicone rubber
- Выбор размера: 26 AWG–500 kcmil style range; table: 26–6 AWG
- Сертификация: AWM с сертификацией UL; UL 758
UL 3580 wire selection
UL 3580 is a UL-certified silicone motor lead wire rated 150°C and 1000 V AC. It is intended for motor leads and internal appliance or electronic equipment wiring where the lead is protected from mechanical abuse.
The detailed size table covers 26–6 AWG. Nominal silicone thickness is 1.20 mm in the 26–10 AWG rows and 1.58 mm in the 8–6 AWG rows. Conductor stranding and finished diameter are listed with each model-size combination to help check motor terminal entries, connection boxes and protective sleeves. A separate insulation schedule explains the larger conductor groups within the style range.
For a motor connection, allow space for the finished wire rather than selecting the entry around the bare conductor size. The listed construction uses a bend radius of 10 times its finished diameter. Check the temperature near the winding exit and at the connection hardware, because the 150°C wire rating must be compatible with the rest of the assembly.
См. таблицы моделей и размеров на вкладке «Характеристики». Просмотрите раздел линейка высокотемпературных кабелей for related constructions. Compare UL 3644 for a different 1 kV wall schedule and the семейство силиконовых соединительных проводов for lower-voltage options.
Конструкция
В проводнике UL 1813 используется следующая система проводников и изоляции. На схеме показана последовательность слоев; выберите конструкцию проводника и изоляцию, указанные в требуемой спецификации размеров.

| Компонент | Детали конструкции |
|---|---|
| Жила | Solid or stranded copper; dimensioned examples are stranded |
| Изоляция | Экструдированная силиконовая резина |
Применения
UL 3580 is used as motor lead wire and for internal appliance or electronic equipment wiring. Route and support the lead to prevent rubbing or mechanical damage at the winding exit and terminal enclosure.

UL 3580 replacement selection
Для подбора замены укажите маркировку имеющегося провода и приложите схему подключения оборудования. Это позволит сопоставить жилу, изоляцию и расположение выводов.
Спецификации
| Параметр | Спецификация |
|---|---|
| Стиль UL | UL 3580 |
| Номинальное напряжение | 1000 V AC |
| Температурный диапазон | 150°C |
| Изоляция / покрытие | extruded silicone rubber |
| Диапазон размеров жилы | 26 AWG–500 kcmil style range; table: 26–6 AWG |
| Bending radius for listed construction | 10 × finished OD |
Nominal dimensions follow the listed conductor constructions. Confirm the agreed finished-diameter drawing for tight-clearance assemblies.
| Модель и размер жилы | Проволок в жиле (шт./mm) | Nominal silicone wall (mm) | Номинальный внешний диаметр / допуск (мм) |
|---|---|---|---|
| UL 3580 6 AWG | 259/0.254 | 1.58 | 7.89 ±0.10 |
| UL 3580 8 AWG | 161/0.254 | 1.58 | 6.88 ±0.10 |
| UL 3580 10 AWG | 105/0.254 | 1.20 | 5.41 ±0.10 |
| UL 3580 12 AWG | 65/0.254 | 1.20 | 4.77 ±0.10 |
| UL 3580 14 AWG | 41/0.254 | 1.20 | 4.28 ±0.10 |
| UL 3580 16 AWG | 26/0.254 | 1.20 | 3.90 ±0.10 |
| UL 3580 18 AWG | 34/0.18 | 1.20 | 3.62 ±0.10 |
| UL 3580 20 AWG | 21/0.18 | 1.20 | 3.36 ±0.10 |
| UL 3580 22 AWG | 17/0.16 | 1.20 | 3.17 ±0.10 |
| UL 3580 24 AWG | 11/0.16 | 1.20 | 3.02 ±0.10 |
| UL 3580 26 AWG | 7/0.16 | 1.20 | 2.89 ±0.10 |
Style construction thicknesses are shown in mils; 1 mil = 0.0254 mm. Nominal finished dimensions are listed separately.
| Model and conductor group | Minimum average silicone wall (mils) | Minimum point wall (mils) |
|---|---|---|
| UL 3580 26–9 AWG | 45 | 40 |
| UL 3580 8–2 AWG | 60 | 54 |
| UL 3580 1–4/0 AWG | 80 | 72 |
| UL 3580 250–500 kcmil | 95 | 86 |
Выбор заданной конструкции
Specify UL 3580 with AWG or kcmil, stranding, required OD and connection temperature. For a size outside the dimension table, use the insulation schedule as a starting point and request the corresponding drawing.
Стандарты
TEBAOFLEX UL 3580 wire is UL-certified appliance wiring material.
| Элемент | Требование или ссылка |
|---|---|
| Сертификация | AWM с сертификацией UL |
| Обозначение стиля | UL 3580 |
| Стандарт конструкции | UL 758 — Материалы для внутренней проводки приборов |
| Классификация стиля по горючести | Горизонтальный огонь |
Укажите в закупочной спецификации стиль UL, размер жилы, номинальное напряжение и температурный класс. Приложите к запросу требуемые данные об изделии и документы о сертификации.
Запросите рекомендации по выбору кабеля и коммерческое предложение.
Укажите необходимые услуги, длину кабеля, механические характеристики, условия эксплуатации, тип разъемов и количество. Наша команда рассмотрит заявку перед составлением коммерческого предложения.
- Укажите название продукта или артикул, а также необходимую длину кабеля и количество.
- При наличии приложите техническое задание, чертеж или спецификацию.