UL 3580 Silicone Motor Lead Wire, 150°C 1000V
UL 3580 is a UL-certified silicone motor lead wire rated 150°C and 1000 V AC. It is intended for motor leads and internal appliance or electronic equipment wiring where the lead is protected from mechanical abuse.
- tension: 1000 V AC
- Température: 150°C
- Isolation / revêtement : extruded silicone rubber
- Sélection de la taille : 26 AWG–500 kcmil style range; table: 26–6 AWG
- Certification : AWM certifié UL; UL 758
UL 3580 wire selection
UL 3580 is a UL-certified silicone motor lead wire rated 150°C and 1000 V AC. It is intended for motor leads and internal appliance or electronic equipment wiring where the lead is protected from mechanical abuse.
The detailed size table covers 26–6 AWG. Nominal silicone thickness is 1.20 mm in the 26–10 AWG rows and 1.58 mm in the 8–6 AWG rows. Conductor stranding and finished diameter are listed with each model-size combination to help check motor terminal entries, connection boxes and protective sleeves. A separate insulation schedule explains the larger conductor groups within the style range.
For a motor connection, allow space for the finished wire rather than selecting the entry around the bare conductor size. The listed construction uses a bend radius of 10 times its finished diameter. Check the temperature near the winding exit and at the connection hardware, because the 150°C wire rating must be compatible with the rest of the assembly.
Consultez l’onglet Caractéristiques pour les tableaux de modèles et de calibres. Parcourez la gamme de câbles haute température for related constructions. Compare UL 3644 for a different 1 kV wall schedule and the gamme de fils de raccordement en silicone for lower-voltage options.
Construction
UL 1813 utilise le système conducteur et d'isolation suivant. Le schéma illustre la séquence des couches ; sélectionnez la construction du conducteur et le revêtement indiqués dans les spécifications de taille requises.

| Composant | détail de construction |
|---|---|
| Conducteur | Solid or stranded copper; dimensioned examples are stranded |
| Isolation | Caoutchouc silicone extrudé |
Applications
UL 3580 is used as motor lead wire and for internal appliance or electronic equipment wiring. Route and support the lead to prevent rubbing or mechanical damage at the winding exit and terminal enclosure.

UL 3580 replacement selection
Pour une demande de remplacement, fournissez le marquage du fil existant et le schéma de raccordement de l’équipement afin de comparer le conducteur, l’isolation et la disposition des bornes.
Caractéristiques techniques
| Paramètre | Spécification |
|---|---|
| Style UL | UL 3580 |
| Tension assignée | 1000 V AC |
| Indice de température | 150°C |
| Isolation / revêtement | extruded silicone rubber |
| Plage de calibres du conducteur | 26 AWG–500 kcmil style range; table: 26–6 AWG |
| Bending radius for listed construction | 10 × finished OD |
Nominal dimensions follow the listed conductor constructions. Confirm the agreed finished-diameter drawing for tight-clearance assemblies.
| Modèle et calibre du conducteur | Brins du conducteur (n°/mm) | Nominal silicone wall (mm) | Diamètre extérieur nominal / tolérance (mm) |
|---|---|---|---|
| UL 3580 6 AWG | 259/0.254 | 1.58 | 7.89 ±0.10 |
| UL 3580 8 AWG | 161/0.254 | 1.58 | 6.88 ±0.10 |
| UL 3580 10 AWG | 105/0.254 | 1.20 | 5.41 ±0.10 |
| UL 3580 12 AWG | 65/0.254 | 1.20 | 4.77 ±0.10 |
| UL 3580 14 AWG | 41/0.254 | 1.20 | 4.28 ±0.10 |
| UL 3580 16 AWG | 26/0.254 | 1.20 | 3.90 ±0.10 |
| UL 3580 18 AWG | 34/0.18 | 1.20 | 3.62 ±0.10 |
| UL 3580 20 AWG | 21/0.18 | 1.20 | 3.36 ±0.10 |
| UL 3580 22 AWG | 17/0.16 | 1.20 | 3.17 ±0.10 |
| UL 3580 24 AWG | 11/0.16 | 1.20 | 3.02 ±0.10 |
| UL 3580 26 AWG | 7/0.16 | 1.20 | 2.89 ±0.10 |
Style construction thicknesses are shown in mils; 1 mil = 0.0254 mm. Nominal finished dimensions are listed separately.
| Model and conductor group | Minimum average silicone wall (mils) | Minimum point wall (mils) |
|---|---|---|
| UL 3580 26–9 AWG | 45 | 40 |
| UL 3580 8–2 AWG | 60 | 54 |
| UL 3580 1–4/0 AWG | 80 | 72 |
| UL 3580 250–500 kcmil | 95 | 86 |
Choix de la construction spécifiée
Specify UL 3580 with AWG or kcmil, stranding, required OD and connection temperature. For a size outside the dimension table, use the insulation schedule as a starting point and request the corresponding drawing.
Normes
TEBAOFLEX UL 3580 wire is UL-certified appliance wiring material.
| Article | Exigence ou référence |
|---|---|
| Certification | AWM certifié UL |
| Désignation du style | UL 3580 |
| Norme de construction | UL 758 — Matériaux de câblage pour appareils |
| Classement au feu du style | Flamme horizontale |
Indiquez le style UL, le calibre du conducteur et les classes de tension et de température dans le cahier des charges. Joignez à la demande l’identification du produit et les documents de certification requis.
Demandez une recommandation et un devis pour un câble.
Veuillez nous indiquer les services requis, la longueur du câble, les contraintes mécaniques, l'environnement, le type de terminaison et la quantité. Notre équipe examinera votre demande avant de vous établir un devis.
- Veuillez inclure le nom du produit ou son SKU, ainsi que la longueur et la quantité de câble requises.
- Joignez une fiche technique, un dessin ou une fiche de spécifications si disponible.