UL 3580 is a UL-certified silicone motor lead wire rated 150°C and 1000 V AC. It is intended for motor leads and internal appliance or electronic equipment wiring where the lead is protected from mechanical abuse.

  • Voltage: 1000 V AC
  • Temperature: 150°C
  • Insulation / covering: extruded silicone rubber
  • Size selection: 26 AWG–500 kcmil style range; table: 26–6 AWG
  • Certification: UL-certified AWM; UL 758
Product information
Product overview

UL 3580 wire selection

UL 3580 is a UL-certified silicone motor lead wire rated 150°C and 1000 V AC. It is intended for motor leads and internal appliance or electronic equipment wiring where the lead is protected from mechanical abuse.

The detailed size table covers 26–6 AWG. Nominal silicone thickness is 1.20 mm in the 26–10 AWG rows and 1.58 mm in the 8–6 AWG rows. Conductor stranding and finished diameter are listed with each model-size combination to help check motor terminal entries, connection boxes and protective sleeves. A separate insulation schedule explains the larger conductor groups within the style range.

For a motor connection, allow space for the finished wire rather than selecting the entry around the bare conductor size. The listed construction uses a bend radius of 10 times its finished diameter. Check the temperature near the winding exit and at the connection hardware, because the 150°C wire rating must be compatible with the rest of the assembly.

See the Specifications tab for the model and size tables. Browse the high-temperature cable range for related constructions. Compare UL 3644 for a different 1 kV wall schedule and the silicone hook-up wire family for lower-voltage options.

Construction

Construction

UL 3580 uses the following conductor and insulation system. The diagram illustrates the layer sequence; select the conductor construction and covering shown in the required size specification.

Illustrative UL 3580 single-core conductor and insulation construction cutaway
Illustrative UL 3580 construction; layer dimensions are not to scale.
UL 3580 construction layers
ComponentConstruction detail
ConductorSolid or stranded copper; dimensioned examples are stranded
InsulationExtruded silicone rubber
Applications

Applications

UL 3580 is used as motor lead wire and for internal appliance or electronic equipment wiring. Route and support the lead to prevent rubbing or mechanical damage at the winding exit and terminal enclosure.

Illustrative UL 3580 insulated lead routed inside industrial equipment
Illustrative UL 3580 equipment application; shown as an installation concept.

UL 3580 replacement selection

For replacement enquiries, include the existing wire marking and the equipment connection drawing so the conductor, insulation and terminal arrangement can be matched.

Specifications

Specifications

UL 3580 technical data
ParameterSpecification
UL styleUL 3580
Voltage rating1000 V AC
Temperature rating150°C
Insulation / coveringextruded silicone rubber
Conductor size coverage26 AWG–500 kcmil style range; table: 26–6 AWG
Bending radius for listed construction10 × finished OD

Nominal dimensions follow the listed conductor constructions. Confirm the agreed finished-diameter drawing for tight-clearance assemblies.

UL 3580 size and dimension table
Model and conductor sizeStranding (No./mm)Nominal silicone wall (mm)Nominal OD / tolerance (mm)
UL 3580 6 AWG259/0.2541.587.89 ±0.10
UL 3580 8 AWG161/0.2541.586.88 ±0.10
UL 3580 10 AWG105/0.2541.205.41 ±0.10
UL 3580 12 AWG65/0.2541.204.77 ±0.10
UL 3580 14 AWG41/0.2541.204.28 ±0.10
UL 3580 16 AWG26/0.2541.203.90 ±0.10
UL 3580 18 AWG34/0.181.203.62 ±0.10
UL 3580 20 AWG21/0.181.203.36 ±0.10
UL 3580 22 AWG17/0.161.203.17 ±0.10
UL 3580 24 AWG11/0.161.203.02 ±0.10
UL 3580 26 AWG7/0.161.202.89 ±0.10

Style construction thicknesses are shown in mils; 1 mil = 0.0254 mm. Nominal finished dimensions are listed separately.

UL 3580 insulation thickness by conductor size
Model and conductor groupMinimum average silicone wall (mils)Minimum point wall (mils)
UL 3580 26–9 AWG4540
UL 3580 8–2 AWG6054
UL 3580 1–4/0 AWG8072
UL 3580 250–500 kcmil9586

Selecting the specified construction

Specify UL 3580 with AWG or kcmil, stranding, required OD and connection temperature. For a size outside the dimension table, use the insulation schedule as a starting point and request the corresponding drawing.

Standards

Standards

TEBAOFLEX UL 3580 wire is UL-certified appliance wiring material.

UL 3580 certification and standards
ItemRequirement or reference
CertificationUL-certified AWM
Style designationUL 3580
Construction standardUL 758 — Appliance Wiring Material
Style flame classificationHorizontal flame

Identify the UL style, conductor size, voltage and temperature grade on the purchasing specification. Include the required product identification and certification documents with the enquiry.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.