UL 5359 Mica-Glass Wire, 600V 200/450°C
UL 5359 is a UL-certified mica-insulated wire rated 600 V AC, with 200°C and 450°C construction options. This page includes a detailed 450°C single-conductor selection table for high-temperature equipment leads protected from mechanical damage.
- Voltaje: 600 V AC
- Temperatura: 200°C or 450°C by construction
- Aislamiento / cubierta: mica tape and treated fiberglass braid
- Selección de tamaño: 30 AWG–4/0 AWG style range; table: 26 AWG–4/0 AWG
- Certificación: AWM con certificación UL; UL 758
UL 5359 wire selection
UL 5359 is a UL-certified mica-insulated wire rated 600 V AC, with 200°C and 450°C construction options. This page includes a detailed 450°C single-conductor selection table for high-temperature equipment leads protected from mechanical damage.
The 18 dimensioned configurations cover 26 AWG through 4/0 AWG. Each row combines UL 5359 with the conductor size and lists stranding, mica thickness, fiberglass-braid thickness and finished diameter. The wall schedule increases in steps as the conductor becomes larger, so the table supports both electrical size selection and the practical fit of sleeves, clamps and equipment entries.
For heater, oven or process-equipment wiring, choose the required temperature grade before comparing diameters. The 200°C and 450°C constructions are separate selections under the same style number. Installation should avoid repeated flexing and protect the mica-and-braid system from mechanical abuse. The operating current must be assessed for the selected conductor, ambient conditions, grouping and complete equipment application.
Consulte la pestaña Especificaciones para ver las tablas de modelos y calibres. Explore la gama de cables de alta temperatura para construcciones relacionadas. Comparar MGT mica-glass wire for the existing 5107/5128 lead wire construction.
Construcción
UL 1056 utiliza el sistema de conductor y aislamiento que se muestra a continuación. El diagrama indica el orden de las capas; seleccione la construcción del conductor y la cubierta que figuran en la especificación del calibre requerido.

| Componente | Detalle de construcción |
|---|---|
| Conductor | Stranded nickel-coated copper or nickel, selected for the required construction |
| Aislamiento | Cinta de mica |
| Cubierta exterior | Treated fiberglass braid |
Aplicaciones
UL 5359 is used for protected internal leads in high-temperature equipment, including heaters and ovens. Keep the mica-insulated lead supported and avoid locations with repeated bending or rubbing.

UL 5359 replacement selection
Para solicitar un repuesto, envíe el marcado del cable existente y el plano de conexión del equipo. Así se podrán comparar el conductor, el aislamiento y la disposición de los terminales.
Especificaciones
| Parámetro | Especificación |
|---|---|
| Estilo UL | UL 5359 |
| Tensión nominal | 600 V AC |
| Clasificación de temperatura | 200°C or 450°C by construction |
| Aislamiento / revestimiento | mica tape and treated fiberglass braid |
| Rango de calibres del conductor | 30 AWG–4/0 AWG style range; table: 26 AWG–4/0 AWG |
| Temperature choices | 200°C or 450°C, according to construction |
| Tensión nominal | 600 V AC |
| Instalación | Protected internal wiring without repeated flexing |
450°C single-conductor dimensional reference. Nominal construction dimensions are for selection; the quotation drawing defines the supplied configuration.
| Modelo y calibre del conductor | Hilos del conductor (n.º/mm) | Mica wall (mm) | Braid wall (mm) | Diámetro exterior nominal / tolerancia (mm) |
|---|---|---|---|---|
| UL 5359 26 AWG | 7/0.16 | 0.41 | 0.18 | 1.8±0.1 |
| UL 5359 24 AWG | 7/0.2 | 0.41 | 0.18 | 1.9±0.1 |
| UL 5359 22 AWG | 7/0.254 | 0.41 | 0.18 | 2.1±0.2 |
| UL 5359 20 AWG | 10/0.254 | 0.41 | 0.18 | 2.2±0.2 |
| UL 5359 18 AWG | 16/0.254 | 0.41 | 0.18 | 2.5±0.2 |
| UL 5359 16 AWG | 26/0.254 | 0.41 | 0.18 | 2.8±0.2 |
| UL 5359 14 AWG | 41/0.254 | 0.41 | 0.18 | 3.2±0.3 |
| UL 5359 12 AWG | 65/0.254 | 0.41 | 0.18 | 3.6±0.3 |
| UL 5359 10 AWG | 103/0.254 | 0.51 | 0.38 | 5.1±0.5 |
| UL 5359 8 AWG | 163/0.254 | 0.51 | 0.38 | 6.0±0.5 |
| UL 5359 6 AWG | 260/0.254 | 0.51 | 0.38 | 7.1±0.5 |
| UL 5359 4 AWG | 413/0.254 | 0.51 | 0.38 | 8.2±0.5 |
| UL 5359 2 AWG | 168/0.5 | 0.64 | 0.51 | 10.5±0.8 |
| UL 5359 1 AWG | 212/0.5 | 0.64 | 0.51 | 11.5±0.8 |
| UL 5359 1/0 AWG | 268/0.5 | 0.64 | 0.51 | 12.7±0.8 |
| UL 5359 2/0 AWG | 342/0.5 | 0.64 | 0.51 | 14.0±0.8 |
| UL 5359 3/0 AWG | 430/0.5 | 0.64 | 0.51 | 15.4±0.8 |
| UL 5359 4/0 AWG | 538/0.5 | 0.64 | 0.51 | 17.0±0.8 |
Style construction thicknesses are shown in mils; 1 mil = 0.0254 mm. Nominal finished dimensions are listed separately.
| Model and conductor group | Minimum average mica wall (mils) | Minimum average treated braid (mils) |
|---|---|---|
| UL 5359 30–12 AWG | 16 | 7 |
| UL 5359 11–4 AWG | 20 | 15 |
| UL 5359 3–4/0 AWG | 25 | 20 |
Selección de la construcción especificada
Specify UL 5359, AWG, 600 V AC and the required 200°C or 450°C construction. The dimension table below applies to the 450°C mica/fiberglass version.
Normas
TEBAOFLEX UL 5359 wire is UL-certified appliance wiring material.
| Artículo | Requisito o referencia |
|---|---|
| Certificación | AWM con certificación UL |
| Designación del estilo | UL 5359 |
| Norma de construcción | UL 758 — Material de cableado para aparatos |
| Clasificación de inflamabilidad del estilo | Llama horizontal |
Indique el estilo UL, el calibre del conductor y los valores de tensión y temperatura en la especificación de compra. Incluya en la consulta la identificación del producto y los documentos de certificación requeridos.
Solicite una recomendación y un presupuesto de cables.
Indique los servicios requeridos, la longitud del cable, la carga mecánica, el entorno, el tipo de terminación y la cantidad. Nuestro equipo revisará la solicitud antes de elaborar un presupuesto.
- Incluya el nombre del producto o SKU, así como la longitud y la cantidad de cable requeridas.
- Adjunte una especificación, un dibujo o una hoja de datos cuando esté disponible.