UL 5359 Mica-Glass Wire, 600V 200/450°C
UL 5359 is a UL-certified mica-insulated wire rated 600 V AC, with 200°C and 450°C construction options. This page includes a detailed 450°C single-conductor selection table for high-temperature equipment leads protected from mechanical damage.
- Напряжение: 600 V AC
- Температура: 200°C or 450°C by construction
- Изоляция / покрытие: mica tape and treated fiberglass braid
- Выбор размера: 30 AWG–4/0 AWG style range; table: 26 AWG–4/0 AWG
- Сертификация: AWM с сертификацией UL; UL 758
UL 5359 wire selection
UL 5359 is a UL-certified mica-insulated wire rated 600 V AC, with 200°C and 450°C construction options. This page includes a detailed 450°C single-conductor selection table for high-temperature equipment leads protected from mechanical damage.
The 18 dimensioned configurations cover 26 AWG through 4/0 AWG. Each row combines UL 5359 with the conductor size and lists stranding, mica thickness, fiberglass-braid thickness and finished diameter. The wall schedule increases in steps as the conductor becomes larger, so the table supports both electrical size selection and the practical fit of sleeves, clamps and equipment entries.
For heater, oven or process-equipment wiring, choose the required temperature grade before comparing diameters. The 200°C and 450°C constructions are separate selections under the same style number. Installation should avoid repeated flexing and protect the mica-and-braid system from mechanical abuse. The operating current must be assessed for the selected conductor, ambient conditions, grouping and complete equipment application.
См. таблицы моделей и размеров на вкладке «Характеристики». Просмотрите раздел линейка высокотемпературных кабелей для аналогичных конструкций. Сравните MGT mica-glass wire for the existing 5107/5128 lead wire construction.
Конструкция
В проводнике UL 1813 используется следующая система проводников и изоляции. На схеме показана последовательность слоев; выберите конструкцию проводника и изоляцию, указанные в требуемой спецификации размеров.

| Компонент | Детали конструкции |
|---|---|
| Жила | Stranded nickel-coated copper or nickel, selected for the required construction |
| Изоляция | Слюдяная лента |
| Наружное покрытие | Treated fiberglass braid |
Применения
UL 5359 is used for protected internal leads in high-temperature equipment, including heaters and ovens. Keep the mica-insulated lead supported and avoid locations with repeated bending or rubbing.

UL 5359 replacement selection
Для подбора замены укажите маркировку имеющегося провода и приложите схему подключения оборудования. Это позволит сопоставить жилу, изоляцию и расположение выводов.
Спецификации
| Параметр | Спецификация |
|---|---|
| Стиль UL | UL 5359 |
| Номинальное напряжение | 600 V AC |
| Температурный диапазон | 200°C or 450°C by construction |
| Изоляция / покрытие | mica tape and treated fiberglass braid |
| Диапазон размеров жилы | 30 AWG–4/0 AWG style range; table: 26 AWG–4/0 AWG |
| Temperature choices | 200°C or 450°C, according to construction |
| Номинальное напряжение | 600 V AC |
| Установка | Protected internal wiring without repeated flexing |
450°C single-conductor dimensional reference. Nominal construction dimensions are for selection; the quotation drawing defines the supplied configuration.
| Модель и размер жилы | Проволок в жиле (шт./mm) | Mica wall (mm) | Braid wall (mm) | Номинальный внешний диаметр / допуск (мм) |
|---|---|---|---|---|
| UL 5359 26 AWG | 7/0.16 | 0.41 | 0.18 | 1.8±0.1 |
| UL 5359 24 AWG | 7/0.2 | 0.41 | 0.18 | 1.9±0.1 |
| UL 5359 22 AWG | 7/0.254 | 0.41 | 0.18 | 2.1±0.2 |
| UL 5359 20 AWG | 10/0.254 | 0.41 | 0.18 | 2.2±0.2 |
| UL 5359 18 AWG | 16/0.254 | 0.41 | 0.18 | 2.5±0.2 |
| UL 5359 16 AWG | 26/0.254 | 0.41 | 0.18 | 2.8±0.2 |
| UL 5359 14 AWG | 41/0.254 | 0.41 | 0.18 | 3.2±0.3 |
| UL 5359 12 AWG | 65/0.254 | 0.41 | 0.18 | 3.6±0.3 |
| UL 5359 10 AWG | 103/0.254 | 0.51 | 0.38 | 5.1±0.5 |
| UL 5359 8 AWG | 163/0.254 | 0.51 | 0.38 | 6.0±0.5 |
| UL 5359 6 AWG | 260/0.254 | 0.51 | 0.38 | 7.1±0.5 |
| UL 5359 4 AWG | 413/0.254 | 0.51 | 0.38 | 8.2±0.5 |
| UL 5359 2 AWG | 168/0.5 | 0.64 | 0.51 | 10.5±0.8 |
| UL 5359 1 AWG | 212/0.5 | 0.64 | 0.51 | 11.5±0.8 |
| UL 5359 1/0 AWG | 268/0.5 | 0.64 | 0.51 | 12.7±0.8 |
| UL 5359 2/0 AWG | 342/0.5 | 0.64 | 0.51 | 14.0±0.8 |
| UL 5359 3/0 AWG | 430/0.5 | 0.64 | 0.51 | 15.4±0.8 |
| UL 5359 4/0 AWG | 538/0.5 | 0.64 | 0.51 | 17.0±0.8 |
Style construction thicknesses are shown in mils; 1 mil = 0.0254 mm. Nominal finished dimensions are listed separately.
| Model and conductor group | Minimum average mica wall (mils) | Minimum average treated braid (mils) |
|---|---|---|
| UL 5359 30–12 AWG | 16 | 7 |
| UL 5359 11–4 AWG | 20 | 15 |
| UL 5359 3–4/0 AWG | 25 | 20 |
Выбор заданной конструкции
Specify UL 5359, AWG, 600 V AC and the required 200°C or 450°C construction. The dimension table below applies to the 450°C mica/fiberglass version.
Стандарты
TEBAOFLEX UL 5359 wire is UL-certified appliance wiring material.
| Элемент | Требование или ссылка |
|---|---|
| Сертификация | AWM с сертификацией UL |
| Обозначение стиля | UL 5359 |
| Стандарт конструкции | UL 758 — Материалы для внутренней проводки приборов |
| Классификация стиля по горючести | Горизонтальный огонь |
Укажите в закупочной спецификации стиль UL, размер жилы, номинальное напряжение и температурный класс. Приложите к запросу требуемые данные об изделии и документы о сертификации.
Запросите рекомендации по выбору кабеля и коммерческое предложение.
Укажите необходимые услуги, длину кабеля, механические характеристики, условия эксплуатации, тип разъемов и количество. Наша команда рассмотрит заявку перед составлением коммерческого предложения.
- Укажите название продукта или артикул, а также необходимую длину кабеля и количество.
- При наличии приложите техническое задание, чертеж или спецификацию.