UL 5359 Mica-Glass Wire, 600V 200/450°C
UL 5359 is a UL-certified mica-insulated wire rated 600 V AC, with 200°C and 450°C construction options. This page includes a detailed 450°C single-conductor selection table for high-temperature equipment leads protected from mechanical damage.
- Tensão: 600 V AC
- Temperatura: 200°C or 450°C by construction
- Isolamento / revestimento: mica tape and treated fiberglass braid
- Seleção de tamanho: 30 AWG–4/0 AWG style range; table: 26 AWG–4/0 AWG
- Certificação: AWM com certificação UL; UL 758
UL 5359 wire selection
UL 5359 is a UL-certified mica-insulated wire rated 600 V AC, with 200°C and 450°C construction options. This page includes a detailed 450°C single-conductor selection table for high-temperature equipment leads protected from mechanical damage.
The 18 dimensioned configurations cover 26 AWG through 4/0 AWG. Each row combines UL 5359 with the conductor size and lists stranding, mica thickness, fiberglass-braid thickness and finished diameter. The wall schedule increases in steps as the conductor becomes larger, so the table supports both electrical size selection and the practical fit of sleeves, clamps and equipment entries.
For heater, oven or process-equipment wiring, choose the required temperature grade before comparing diameters. The 200°C and 450°C constructions are separate selections under the same style number. Installation should avoid repeated flexing and protect the mica-and-braid system from mechanical abuse. The operating current must be assessed for the selected conductor, ambient conditions, grouping and complete equipment application.
Consulte o separador Especificações para ver as tabelas de modelos e tamanhos. Explore a gama de cabos de alta temperatura para construções relacionadas. Compare. MGT mica-glass wire for the existing 5107/5128 lead wire construction.
Construção
O UL 1056 utiliza o sistema de condutor e isolamento indicado a seguir. O esquema mostra a sequência das camadas; selecione a construção do condutor e o revestimento previstos na especificação do tamanho necessário.

| Componente | Detalhes da construção |
|---|---|
| Condutor | Stranded nickel-coated copper or nickel, selected for the required construction |
| Isolamento | Fita de mica |
| Revestimento exterior | Treated fiberglass braid |
Aplicações
UL 5359 is used for protected internal leads in high-temperature equipment, including heaters and ovens. Keep the mica-insulated lead supported and avoid locations with repeated bending or rubbing.

UL 5359 replacement selection
Para pedir um fio de substituição, envie a marcação do fio existente e o esquema de ligação do equipamento. Assim, podem comparar-se o condutor, o isolamento e a disposição dos terminais.
Especificações
| Parâmetro | Especificação |
|---|---|
| Estilo UL | UL 5359 |
| Tensão nominal | 600 V AC |
| Classificação de temperatura | 200°C or 450°C by construction |
| Isolamento/revestimento | mica tape and treated fiberglass braid |
| Gama de tamanhos do condutor | 30 AWG–4/0 AWG style range; table: 26 AWG–4/0 AWG |
| Temperature choices | 200°C or 450°C, according to construction |
| Tensão nominal | 600 V AC |
| Instalação | Protected internal wiring without repeated flexing |
450°C single-conductor dimensional reference. Nominal construction dimensions are for selection; the quotation drawing defines the supplied configuration.
| Modelo e tamanho do condutor | Fios do condutor (n.º/mm) | Mica wall (mm) | Braid wall (mm) | Diâmetro externo nominal / tolerância (mm) |
|---|---|---|---|---|
| UL 5359 26 AWG | 7/0.16 | 0.41 | 0.18 | 1.8±0.1 |
| UL 5359 24 AWG | 7/0.2 | 0.41 | 0.18 | 1.9±0.1 |
| UL 5359 22 AWG | 7/0.254 | 0.41 | 0.18 | 2.1±0.2 |
| UL 5359 20 AWG | 10/0.254 | 0.41 | 0.18 | 2.2±0.2 |
| UL 5359 18 AWG | 16/0.254 | 0.41 | 0.18 | 2.5±0.2 |
| UL 5359 16 AWG | 26/0.254 | 0.41 | 0.18 | 2.8±0.2 |
| UL 5359 14 AWG | 41/0.254 | 0.41 | 0.18 | 3.2±0.3 |
| UL 5359 12 AWG | 65/0.254 | 0.41 | 0.18 | 3.6±0.3 |
| UL 5359 10 AWG | 103/0.254 | 0.51 | 0.38 | 5.1±0.5 |
| UL 5359 8 AWG | 163/0.254 | 0.51 | 0.38 | 6.0±0.5 |
| UL 5359 6 AWG | 260/0.254 | 0.51 | 0.38 | 7.1±0.5 |
| UL 5359 4 AWG | 413/0.254 | 0.51 | 0.38 | 8.2±0.5 |
| UL 5359 2 AWG | 168/0.5 | 0.64 | 0.51 | 10.5±0.8 |
| UL 5359 1 AWG | 212/0.5 | 0.64 | 0.51 | 11.5±0.8 |
| UL 5359 1/0 AWG | 268/0.5 | 0.64 | 0.51 | 12.7±0.8 |
| UL 5359 2/0 AWG | 342/0.5 | 0.64 | 0.51 | 14.0±0.8 |
| UL 5359 3/0 AWG | 430/0.5 | 0.64 | 0.51 | 15.4±0.8 |
| UL 5359 4/0 AWG | 538/0.5 | 0.64 | 0.51 | 17.0±0.8 |
Style construction thicknesses are shown in mils; 1 mil = 0.0254 mm. Nominal finished dimensions are listed separately.
| Model and conductor group | Minimum average mica wall (mils) | Minimum average treated braid (mils) |
|---|---|---|
| UL 5359 30–12 AWG | 16 | 7 |
| UL 5359 11–4 AWG | 20 | 15 |
| UL 5359 3–4/0 AWG | 25 | 20 |
Seleção da construção especificada
Specify UL 5359, AWG, 600 V AC and the required 200°C or 450°C construction. The dimension table below applies to the 450°C mica/fiberglass version.
Normas
TEBAOFLEX UL 5359 wire is UL-certified appliance wiring material.
| Item | Requisito ou referência |
|---|---|
| Certificação | AWM com certificação UL |
| Designação do estilo | UL 5359 |
| Norma de construção | UL 758 — Material de cablagem para aparelhos |
| Classificação de inflamabilidade do estilo | Chama horizontal |
Indique o estilo UL, o tamanho do condutor e as classificações de tensão e temperatura na especificação de compra. Junte ao pedido a identificação do produto e os documentos de certificação exigidos.
Solicite uma recomendação e orçamento de cabos.
Envie-nos as especificações dos serviços necessários, comprimento do cabo, capacidade mecânica, ambiente, tipo de terminação e quantidade. Nossa equipe analisará a solicitação antes de enviar um orçamento.
- Inclua o nome do produto ou o código SKU, além do comprimento e da quantidade de cabos necessários.
- Anexe uma especificação, desenho ou ficha técnica, quando disponíveis.