Obtenir un devis
CÂBLES MINIERS ET DE TUNNELAGE Modèle / construction

Type 7S BS 6708 640/1100 V Three-Core Pilot Mining Cable

Type 7S mining cable for excavating, crushing and coal-cutting equipment, with the source-defined 640/1100 V rating and 3 kV; 2.5 kV pilot test reference.

  • Model: Type 7S
  • Conductor and insulation: flexible tinned copper with the insulation and core construction listed for this model in the supplied PDF
  • Screen, pilot, earth and armour arrangement preserved from the source datasheet
  • Heavy-duty chloroprene or PCP outer protection as listed for this model
  • Original Type datasheet available as the product download

Send the equipment, voltage, conductor area, route, quantity and document requirements for an RFQ.

Informations sur le produit
Marque
Modèle / construction
Présentation du produit

Type 7S for excavating, crushing and coal-cutting equipment

Type 7S mining cable is specified in the supplied BS 6708 datasheet for excavating, crushing and coal-cutting equipment. This page keeps the source-listed voltage, test reference, core functions and dimensional tables together so a procurement engineer can compare the requested model against the cable marking and the equipment connection. The editorial focus is the pilot-unit decision for coalface machinery, not a generic promise of performance.

The supplied construction uses three individually screened phase cores plus one unscreened three-core pilot unit, laid up around the central bare earth conductor and protected by a heavy-duty chloroprene sheath. That arrangement matters because Type 7S uses an unscreened three-core pilot unit, unlike the single pilot arrangements of Type 7 and Type 7M. The family should therefore be selected by model, core function and installation route as well as by voltage. The gamme de câbles pour l'exploitation minière et le creusement de tunnels provides the wider TEBAOFLEX product context.

  • Choisir par : confirm the pilot-unit core count and the separate 2.5 kV pilot test requirement before ordering.
  • Confirmez avant de commander : existing sheath marking, conductor area, cable length, route, support or handling system, terminations and the required inspection documents.
  • Do not infer: values not listed in the supplied PDF, such as a different current basis, water/oil/UV performance, certification scope or mechanical interchangeability.

Where a three-core pilot layout is being compared with adjacent models, the BS 6708 mining cable replacement guide provides a useful model-by-model screening checklist.

For a technical quotation, send the equipment nameplate or existing cable marking, voltage and size requirement, installation conditions, quantity, destination and any project-specific test or documentation requirement.

Construction

Type 7S construction

The cross-section below is the supplied construction drawing for Type 7S. The ordering decision is driven by Type 7S uses an unscreened three-core pilot unit, unlike the single pilot arrangements of Type 7 and Type 7M.

Type 7S cable cross-section showing the supplied power, pilot, earth, screen and protection arrangement
Supplied Type 7S cross-section; the exact core and armour arrangement must be checked against the product datasheet.

Source-listed construction

Élément de constructionValeur indiquée dans la source
ConducteurElectrolytic stranded tinned copper wire, IEC 60228 Class 5
IsolationEPR; ground core is not insulated
ÉcranTinned copper and nylon braided screen over phase cores; pilot unit is not screened
Pilot unitOne unscreened pilot unit with three thinner cores
Lay-upThree phase cores with composite individual screens and one pilot unit laid up in contact with the bare earth conductor in the centre
GaineHeavy-duty chloroprene outer sheath

Do not use the drawing as a substitute for the dimensional tables. Confirm the cable end preparation, screen and earth termination, armour bonding and machine interface with the equipment documentation before installation.

Applications

Type 7S applications

Type 7S mining cable application with underground longwall mining equipment
Media-library application scene showing underground longwall mining equipment; used for application context, not as a model-specific construction proof.

The supplied datasheet identifies this cable for excavating, crushing and coal-cutting equipment. Google result patterns for the BS 6708 family also separate cables by equipment duty, voltage class, core function and whether the route is armoured, screened, flat or auxiliary. That is why this page keeps the Type 7S construction separate from nearby Type numbers.

  • Primary duty: excavating, crushing and coal-cutting equipment.
  • Model boundary: Type 7S uses an unscreened three-core pilot unit, unlike the single pilot arrangements of Type 7 and Type 7M.
  • Project check: match the cable marking, core map, voltage, termination, route geometry and handling method to the machine drawing.
  • Environmental review: confirm the actual mine/quarry conditions and any authority, inspection or documentation requirements; do not infer a certification or material-resistance claim from the model number.

For a nearby screened-pilot option with a different model definition, review the Type 11 mining cable and compare its core map with the equipment documentation before ordering.

The cable should be released only after the equipment route, required length, conductor area, core functions and connection details are agreed. If the intended duty is different from the source-listed application, request an engineering review through the quotation process.

Caractéristiques

Type 7S specifications

The summary below identifies the supplied model family. The source-transcribed tables that follow retain the PDF's dimensional, electrical and construction values, including available sizes, resistance, current, diameter, mass, bending or pulling data when the PDF provides them.

Selection itemSource-linked value
ModèleType 7S
Tension nominale640/1100 V
Tension d'essai3 kV; 2.5 kV pilot
Applicationexcavating, crushing and coal-cutting equipment
Norme du produitBS 6708

Complete source-transcribed technical tables

Source PDF: BS6708_TYPE_7S_640_1100V_CABLE_datasheet.pdf; 3 pages; 7 extracted tables. Values are not recalculated or replaced by third-party values.

Source table 1, PDF page 1
ParamètreValeur
ConducteurElectrolytic stranded tinned copper wire, IEC 60228 Class 5
IsolationEPR insulation; ground core is not insulated
SéparateurColoured textile tape for core identification
ÉcranTinned copper and nylon braided screen over phase cores; pilot unit is not screened
Pilot unitOne unscreened pilot unit with three thinner cores
Lay-upThree phase cores with composite individual screens and one pilot unit laid up in contact with the bare earth conductor in the centre
LiterieRubber based bedding compound
gaine extérieureHeavy duty chloroprene outer sheath
Source table 2, PDF page 1
ParamètreValeur
StandardBS 6708
Tension nominale640/1100 V
Tension d'essai3 kV; 2.5 kV for pilot cores
Type de câbleComposite individually screened phase cores with unscreened three-core pilot unit and central bare earth conductor
Source table 1, PDF page 2
CORE DIMENSIONS
Nominal cross sectionconducteur de phasePhase stranding mmCond. dia. mmInsul. dia. mmScreen dia. mmconducteur de terrePilot conductor
3x50+25+3x43x50396/0.409.7513.6015.901x253x4
3x70+35+3x63x70360/0.5011.6015.7018.001x353x6
3x95+50+3x63x95475/0.5012.7517.2519.551x503x6
3x120+50+3x103x120608/0.5015.1020.0522.351x503x10
3x150+70+3x103x150740/0.5017.0022.2024.501x703x10
Source table 2, PDF page 2
PILOT UNIT DETAILS
Nominal cross sectionPilot conductorsPilot stranding mmPilot cond. dia. mmPilot insul. dia. mmPilot unit dia. mm
3x50+25+3x43x456/0.302.605.5515.60
3x70+35+3x63x684/0.303.506.4017.70
3x95+50+3x63x684/0.303.506.4019.25
3x120+50+3x103x1080/0.404.407.3022.05
3x150+70+3x103x1080/0.404.407.3024.20
Source table 3, PDF page 2
CABLE DETAILS
Nominal cross sectionMin. OD mmMax. OD mmMin. bend radius mmMax pulling tension kgfApprox. weight kg/kmCopper weight kg/km
3x50+25+3x448.551.8420112044502200
3x70+35+3x655.158.8470157060803150
3x95+50+3x662.466.1530200066504250
3x120+50+3x1068.072.5580200083004800
3x150+70+3x1070.478.46302000105005300
Source table 1, PDF page 3
CURRENT RATINGS
Nominal cross sectionContinuous current rating at 25 deg CIntermittent current rating at 25 deg C
3x50+25+3x4170200
3x70+35+3x6205250
3x95+50+3x6250310
3x120+50+3x10295355
3x150+70+3x10320385
Source table 2, PDF page 3
ELECTRICAL DETAILS
Nominal croBss sectionPhase DC res. 20 deg C ohm/kmPilot DC res. 20 deg C ohm/kmScreens+earth res. ohm/kmReactance 50 Hz ohm/kmReactance 60 Hz ohm/kmMin. insul. res. Mohm/kmVoltage drop mV/A/m
3x50+25+3x40.3935.470.440.0980.1182850.84
3x70+35+3x60.2773.600.300.0950.1142600.61
3x95+50+3x60.2103.600.260.0940.1132500.47
3x120+50+3x100.1642.090.240.0920.1102500.38
3x150+70+3x100.1322.090.1760.0800.0962500.32

Use the table values with the equipment drawing and approved termination plan. If the requested conductor area, current basis, mechanical limit or environmental condition is not listed in the supplied PDF, treat it as a quotation-stage confirmation item.

Normes

Type 7S standards and references

ObjetSource-linked reference
Norme du produitBS 6708
Tension nominale640/1100 V
Tension d'essai3 kV; 2.5 kV pilot
Source applicationexcavating, crushing and coal-cutting equipment

The product page preserves the BS 6708 reference appearing in the supplied PDF. The BSI record currently identifies BS 6708:1998 as withdrawn on 22 May 2026; this status note is a standards-reference update, not a claim that the product is currently certified or approved. See the official BSI BS 6708 scope record for the published status.

For an RFQ, state the required standard documents, inspection scope, test report, cable marking, destination rules and any replacement-equivalence requirement. The model number alone does not establish legal installation compliance.

Comparer par fonction

Options de câbles associées

Comparez ces options de câbles en fonction de la combinaison de services, du mouvement, de la charge, de la tension et des exigences de transmission.

devis basé sur l'ingénierie

Demandez une recommandation et un devis pour un câble.

Veuillez nous indiquer les services requis, la longueur du câble, les contraintes mécaniques, l'environnement, le type de terminaison et la quantité. Notre équipe examinera votre demande avant de vous établir un devis.

  • Veuillez inclure le nom du produit ou son SKU, ainsi que la longueur et la quantité de câble requises.
  • Joignez une fiche technique, un dessin ou une fiche de spécifications si disponible.

    Facultatif : joindre une spécification de câble, un dessin, une fiche technique ou une image du produit (PDF, DOC, DOCX, XLS, XLSX, CSV, JPG ou PNG ; maximum 10 Mo).

    En soumettant ce formulaire, vous acceptez que TEBAOFLEX utilise vos coordonnées et les fichiers fournis pour examiner votre demande et y répondre. Les fichiers servent à l'établissement du devis et aux échanges techniques relatifs à votre demande. Consultez notre politique de confidentialité. politique de confidentialité pour obtenir des informations à jour sur le traitement et la conservation des données.

    * Champs obligatoires. Veuillez inclure les détails du câble principal ou de l'application pour examen.