H07G-U, H07G-R and H07G-K 450/750 V EVA Cables
H07G-U, H07G-R and H07G-K are 450/750 V EVA-insulated single-core cables for protected internal fixed wiring.
- H07G-U: Class 1 solid copper
- H07G-R: Class 2 stranded copper
- H07G-K: Class 5 flexible stranded copper
- Maximum operating temperature: +110°C
Request a quote with the required type, size, colour and length.
H07G-U, H07G-R and H07G-K EVA insulated cables
TEBAOFLEX H07G-U, H07G-R and H07G-K are 450/750 V single-core, high-temperature low-voltage power cables for fixed wiring in protected internal installations, including dry and clean environments. The three H07G cable types use EVA (ethylene vinyl acetate) rubber insulation, with a stated maximum operating temperature of +110°C. Select the conductor construction to suit the installation: H07G-U uses Class 1 solid copper, H07G-R Class 2 stranded copper and H07G-K Class 5 flexible stranded copper.
H07G-U, H07G-R and H07G-K share the supplied voltage and insulation platform but are not interchangeable solely by conductor size. H07G-K is intended where the installation route benefits from greater manoeuvrability; the final choice must account for the approved wiring method, bending, termination, protection, conductor class and applicable installation rules.
- tension: 450/750 V.
- Isolation: EVA rubber.
- Température: +110°C maximum operating temperature; +250°C maximum conductor short-circuit temperature; +5°C minimum installation temperature.
- Référence standard : EN 50525; flame retardant to IEC/EN 60332-1-2.
Voir le gamme de câbles industriels for related products. Send the required H07G-U, H07G-R or H07G-K type, cross-section, colour, length and documentation requirements for a quotation.
Construction
The supplied construction image distinguishes the solid, stranded and flexible conductor formats within this H07G-U, H07G-R and H07G-K aggregate page.
| Taper | Conducteur | Isolation | Tension |
|---|---|---|---|
| H07G-U | Class 1 solid copper | EVA rubber (ethylene vinyl acetate) | 450/750 V |
| H07G-R | Class 2 stranded copper | ||
| H07G-K | Class 5 flexible stranded copper |
Applications
H07G-U, H07G-R and H07G-K cables are supplied for fixed wiring in protected internal installations in dry, clean environments. Choose H07G-K where the stated Class 5 flexible construction helps with more complex installation routing; assess each route and termination against the project requirements.
- Confirm the installation method, conductor type and cross-section before ordering.
- Use the supplied temperature limits within the complete installation design.
- Specify H07G-U, H07G-R or H07G-K, insulation colour, length and required documentation in the enquiry.
Caractéristiques techniques
H07G-U nominal data
| Zone | Min. OD | Max. OD | Poids |
|---|---|---|---|
| 1,5 mm² | 2.8 mm | 3.5 mm | 25 kg/km |
| 2.5 mm² | 3,4 mm | 4,3 mm | 38 kg/km |
| 4 mm² | 4,0 mm | 5,0 mm | 57 kg/km |
| 6 mm² | 4,5 mm | 5,6 mm | 79 kg/km |
| 10 mm² | 5.7 mm | 7.1 mm | 129 kg/km |
H07G-R nominal data
| Zone | Min. OD | Max. OD | Poids |
|---|---|---|---|
| 1,5 mm² | 2.9 | 3.7 | 25 |
| 2.5 mm² | 3.5 | 4.4 | 39 |
| 4 mm² | 4.2 | 5.2 | 58 |
| 6 mm² | 4.7 | 5.9 | 81 |
| 10 mm² | 6.0 | 7.4 | 131 |
| 16 mm² | 6.8 | 8.5 | 195 |
| 25 mm² | 8.4 | 10.6 | 301 |
| 35 mm² | 9.4 | 11.8 | 405 |
| 50 mm² | 10.9 | 13.7 | 571 |
| 70 mm² | 12.5 | 15.6 | 778 |
| 95 mm² | 14.5 | 18.1 | 1050 |
| 120 mm² | 15.9 | 19.9 | 1306 |
| 150 mm² | 17.7 | 22.1 | 1629 |
| 185 mm² | 19.7 | 24.6 | 2008 |
| 240 mm² | 22.4 | 28.0 | 2594 |
H07G-K nominal data
| Zone | Min. OD | Max. OD | Poids |
|---|---|---|---|
| 1,5 mm² | 3.0 | 3.7 | 25 kg/km |
| 2.5 mm² | 3.6 | 4.5 | 39 kg/km |
| 4 mm² | 4.3 | 5.4 | 59 kg/km |
| 6 mm² | 4.8 | 6.0 | 81 kg/km |
| 10 mm² | 6.0 | 7.6 | 132 kg/km |
| 16 mm² | 7.1 | 8.9 | 197 kg/km |
| 25 mm² | 8.8 | 11.0 | 303 kg/km |
| 35 mm² | 10.1 | 12.6 | 410 kg/km |
| 50 mm² | 11.9 | 14.9 | 580 kg/km |
| 70 mm² | 13.6 | 17.0 | 788 kg/km |
| 95 mm² | 15.5 | 19.3 | 1060 kg/km |
| 120 mm² | 17.1 | 21.4 | 1318 kg/km |
| 150 mm² | 19.0 | 23.8 | 1645 kg/km |
| 185 mm² | 21.0 | 26.3 | 2026 kg/km |
| 240 mm² | 23.9 | 29.9 | 2615 kg/km |
Normes
| Product standard | EN 50525 |
|---|---|
| Flame retardance reference | IEC/EN 60332-1-2 |
| Other supplied statement | CPR compliant |
Options de câbles associées
Comparez ces options de câbles en fonction de la combinaison de services, du mouvement, de la charge, de la tension et des exigences de transmission.
Type G Cable 2 kV Portable Mining Power Cable
Une option de câble similaire pour une application ou un profil de service différent.
Voir le produitType SHD-CGC 5 kV Shielded Portable Mining Power Cable
Une option de câble similaire pour une application ou un profil de service différent.
Voir le produitCâble d'enroulement minier LHD NSHTOEU 0,6/1 kV
Une option de câble similaire pour une application ou un profil de service différent.
Voir le produitDemandez une recommandation et un devis pour un câble.
Veuillez nous indiquer les services requis, la longueur du câble, les contraintes mécaniques, l'environnement, le type de terminaison et la quantité. Notre équipe examinera votre demande avant de vous établir un devis.
- Veuillez inclure le nom du produit ou son SKU, ainsi que la longueur et la quantité de câble requises.
- Joignez une fiche technique, un dessin ou une fiche de spécifications si disponible.