UL 5390 Mica-Glass Wire, 550°C 300V
UL 5390 is a UL-certified mica-glass wire rated 550°C and 300 V AC for internal equipment wiring. Its high-temperature insulation system combines mica with a treated fiberglass braid around the conductor.
- Tensione: 300 V AC
- Temperatura: 550°C
- Isolamento / rivestimento: mica composite with treated fiberglass braid
- Scelta della sezione: 24–4 AWG style range; table: 24–14 AWG
- Certificazione: AWM certificato UL; UL 758
UL 5390 wire selection
UL 5390 is a UL-certified mica-glass wire rated 550°C and 300 V AC for internal equipment wiring. Its high-temperature insulation system combines mica with a treated fiberglass braid around the conductor.
The dimension table gives six stranded nickel-coated copper configurations from 24 AWG to 14 AWG. Every row identifies UL 5390 with the wire size and includes strand count, finished diameter, approximate weight and minimum bend radius. A separate thickness schedule covers the wider 24–4 AWG style range. This keeps dimensioned constructions distinct from the broader conductor sizes permitted by the style.
For a hot-zone equipment lead, confirm the temperature at the wire and termination, the required operating voltage and the space available for a supported route. The 550°C rating does not increase the 300 V voltage rating. The optional stainless-steel braid shield is a separate construction choice and should be stated on the order if required; it is not included in the unshielded dimension table.
Consulta la scheda Specifiche per le tabelle di modelli e sezioni. Esplora la categoria gamma di cavi per alte temperature for related constructions. Compare the 450°C MGT mica-glass wire and the separate 600 V UL 5359 construction.
Costruzione
UL 5390 uses the following conductor and insulation system. The diagram illustrates the layer sequence; select the conductor construction and covering shown in the required size specification.

| Componente | Dettaglio costruttivo |
|---|---|
| Conduttore | Stranded 27% nickel-coated copper in the dimensioned construction |
| Isolamento | Mica-glass composite |
| Rivestimento esterno | Treated fiberglass braid |
| Optional style construction | 304 stainless-steel braid shield |
Applicazioni
UL 5390 is intended for internal equipment wiring requiring a 550°C mica-glass construction at 300 V AC. Review the hot-zone route, terminal materials and mechanical protection together before selecting the conductor size.

UL 5390 replacement selection
Per richiedere un ricambio, inviare la marcatura del filo esistente e lo schema di collegamento dell’apparecchiatura, così da confrontare conduttore, isolamento e disposizione dei morsetti.
Dati tecnici
| Parametro | Specifica |
|---|---|
| Stile UL | UL 5390 |
| Tensione nominale | 300 V AC |
| Temperatura nominale | 550°C |
| Isolamento / rivestimento | mica composite with treated fiberglass braid |
| Gamma delle sezioni del conduttore | 24–4 AWG style range; table: 24–14 AWG |
| Costruzione | Single conductor with non-extruded insulation |
Unshielded 550°C, 300 V construction dimensions for selection. Values are nominal; the quotation drawing defines the supplied construction.
| Modello e sezione del conduttore | Fili elementari | OD (mm) | OD (in) | Peso (kg/km) | Weight (lb/1000 ft) | Raggio minimo di curvatura (in) |
|---|---|---|---|---|---|---|
| UL 5390 24 AWG | 7 | 2.03 | 0.080 | 7.22 | 5 | 0.64 |
| UL 5390 22 AWG | 7 | 2.21 | 0.087 | 8.86 | 6 | 0.70 |
| UL 5390 20 AWG | 10 | 2.34 | 0.092 | 10.37 | 7 | 0.74 |
| UL 5390 18 AWG | 16 | 2.64 | 0.104 | 15.30 | 10 | 0.83 |
| UL 5390 16 AWG | 26 | 3.05 | 0.120 | 22.49 | 15 | 0.96 |
| UL 5390 14 AWG | 41 | 3.30 | 0.130 | 29.69 | 20 | 1.04 |
Style construction thicknesses are shown in mils; 1 mil = 0.0254 mm. Nominal finished dimensions are listed separately.
| Model and conductor group | Minimum average composite wall (mils) | Minimum point wall (mils) |
|---|---|---|
| UL 5390 24–12 AWG | 25 | 22 |
| UL 5390 11–4 AWG | 33 | 30 |
Selezione della costruzione specificata
Specify UL 5390 with AWG, conductor material, 300 V AC duty and any shield requirement. Use the selected row for nominal OD, weight and bend radius, and request a drawing for sizes beyond the dimensioned table.
Norme
TEBAOFLEX UL 5390 wire is UL-certified appliance wiring material.
| Voce | Requisito o riferimento |
|---|---|
| Certificazione | AWM certificato UL |
| Designazione dello stile | UL 5390 |
| Norma costruttiva | UL 758 — Materiale per il cablaggio degli apparecchi |
| Classificazione di infiammabilità dello stile | Prova di fiamma orizzontale |
Nella specifica d’acquisto indicare lo stile UL, la sezione del conduttore e le classi di tensione e temperatura. Allegare alla richiesta l’identificazione del prodotto e i documenti di certificazione richiesti.
Richiedi una proposta di cavo e un preventivo
Invia le funzioni richieste, la lunghezza del cavo, le condizioni di servizio meccanico, l'ambiente, le terminazioni e la quantità. Il nostro team esaminerà l'applicazione prima di formulare il preventivo.
- Indica il nome del prodotto o lo SKU, oltre alla lunghezza del cavo e alla quantità richieste.
- Allega una specifica, un disegno o una scheda tecnica, se disponibili.