Richiedi un'offerta
Cavi per alte temperature

UL 5390 Mica-Glass Wire, 550°C 300V

UL 5390 is a UL-certified mica-glass wire rated 550°C and 300 V AC for internal equipment wiring. Its high-temperature insulation system combines mica with a treated fiberglass braid around the conductor.

  • Tensione: 300 V AC
  • Temperatura: 550°C
  • Isolamento / rivestimento: mica composite with treated fiberglass braid
  • Scelta della sezione: 24–4 AWG style range; table: 24–14 AWG
  • Certificazione: AWM certificato UL; UL 758
Informazioni sul prodotto
Panoramica del prodotto

UL 5390 wire selection

UL 5390 is a UL-certified mica-glass wire rated 550°C and 300 V AC for internal equipment wiring. Its high-temperature insulation system combines mica with a treated fiberglass braid around the conductor.

The dimension table gives six stranded nickel-coated copper configurations from 24 AWG to 14 AWG. Every row identifies UL 5390 with the wire size and includes strand count, finished diameter, approximate weight and minimum bend radius. A separate thickness schedule covers the wider 24–4 AWG style range. This keeps dimensioned constructions distinct from the broader conductor sizes permitted by the style.

For a hot-zone equipment lead, confirm the temperature at the wire and termination, the required operating voltage and the space available for a supported route. The 550°C rating does not increase the 300 V voltage rating. The optional stainless-steel braid shield is a separate construction choice and should be stated on the order if required; it is not included in the unshielded dimension table.

Consulta la scheda Specifiche per le tabelle di modelli e sezioni. Esplora la categoria gamma di cavi per alte temperature for related constructions. Compare the 450°C MGT mica-glass wire and the separate 600 V UL 5359 construction.

Costruzione

Costruzione

UL 5390 uses the following conductor and insulation system. The diagram illustrates the layer sequence; select the conductor construction and covering shown in the required size specification.

Illustrative UL 5390 single-core conductor and insulation construction cutaway
Illustrative UL 5390 construction; layer dimensions are not to scale.
UL 5390 construction layers
ComponenteDettaglio costruttivo
ConduttoreStranded 27% nickel-coated copper in the dimensioned construction
IsolamentoMica-glass composite
Rivestimento esternoTreated fiberglass braid
Optional style construction304 stainless-steel braid shield
Applicazioni

Applicazioni

UL 5390 is intended for internal equipment wiring requiring a 550°C mica-glass construction at 300 V AC. Review the hot-zone route, terminal materials and mechanical protection together before selecting the conductor size.

Illustrative UL 5390 insulated lead routed inside industrial equipment
Illustrative UL 5390 equipment application; shown as an installation concept.

UL 5390 replacement selection

Per richiedere un ricambio, inviare la marcatura del filo esistente e lo schema di collegamento dell’apparecchiatura, così da confrontare conduttore, isolamento e disposizione dei morsetti.

Dati tecnici

Dati tecnici

UL 5390 technical data
ParametroSpecifica
Stile ULUL 5390
Tensione nominale300 V AC
Temperatura nominale550°C
Isolamento / rivestimentomica composite with treated fiberglass braid
Gamma delle sezioni del conduttore24–4 AWG style range; table: 24–14 AWG
CostruzioneSingle conductor with non-extruded insulation

Unshielded 550°C, 300 V construction dimensions for selection. Values are nominal; the quotation drawing defines the supplied construction.

UL 5390 size and dimension table
Modello e sezione del conduttoreFili elementariOD (mm)OD (in)Peso (kg/km)Weight (lb/1000 ft)Raggio minimo di curvatura (in)
UL 5390 24 AWG72.030.0807.2250.64
UL 5390 22 AWG72.210.0878.8660.70
UL 5390 20 AWG102.340.09210.3770.74
UL 5390 18 AWG162.640.10415.30100.83
UL 5390 16 AWG263.050.12022.49150.96
UL 5390 14 AWG413.300.13029.69201.04

Style construction thicknesses are shown in mils; 1 mil = 0.0254 mm. Nominal finished dimensions are listed separately.

UL 5390 insulation thickness by conductor size
Model and conductor groupMinimum average composite wall (mils)Minimum point wall (mils)
UL 5390 24–12 AWG2522
UL 5390 11–4 AWG3330

Selezione della costruzione specificata

Specify UL 5390 with AWG, conductor material, 300 V AC duty and any shield requirement. Use the selected row for nominal OD, weight and bend radius, and request a drawing for sizes beyond the dimensioned table.

Norme

Norme

TEBAOFLEX UL 5390 wire is UL-certified appliance wiring material.

UL 5390 certification and standards
VoceRequisito o riferimento
CertificazioneAWM certificato UL
Designazione dello stileUL 5390
Norma costruttivaUL 758 — Materiale per il cablaggio degli apparecchi
Classificazione di infiammabilità dello stileProva di fiamma orizzontale

Nella specifica d’acquisto indicare lo stile UL, la sezione del conduttore e le classi di tensione e temperatura. Allegare alla richiesta l’identificazione del prodotto e i documenti di certificazione richiesti.

Preventivo basato sulla valutazione tecnica

Richiedi una proposta di cavo e un preventivo

Invia le funzioni richieste, la lunghezza del cavo, le condizioni di servizio meccanico, l'ambiente, le terminazioni e la quantità. Il nostro team esaminerà l'applicazione prima di formulare il preventivo.

  • Indica il nome del prodotto o lo SKU, oltre alla lunghezza del cavo e alla quantità richieste.
  • Allega una specifica, un disegno o una scheda tecnica, se disponibili.

    Inviando questo modulo, accetti che TEBAOFLEX utilizzi i recapiti e i file forniti per esaminare la tua richiesta e rispondere. I file sono utilizzati per l'offerta e la comunicazione tecnica relative alla richiesta. Consulta la nostra Informativa sulla privacy per le informazioni aggiornate sul trattamento e sulla conservazione dei dati.