UL 5359 Mica-Glass Wire, 600V 200/450°C
UL 5359 is a UL-certified mica-insulated wire rated 600 V AC, with 200°C and 450°C construction options. This page includes a detailed 450°C single-conductor selection table for high-temperature equipment leads protected from mechanical damage.
- Napięcie: 600 V AC
- Temperatura: 200°C or 450°C by construction
- Izolacja / powłoka: mica tape and treated fiberglass braid
- Dobór przekroju: 30 AWG–4/0 AWG style range; table: 26 AWG–4/0 AWG
- Certyfikacja: AWM z certyfikatem UL; UL 758
UL 5359 wire selection
UL 5359 is a UL-certified mica-insulated wire rated 600 V AC, with 200°C and 450°C construction options. This page includes a detailed 450°C single-conductor selection table for high-temperature equipment leads protected from mechanical damage.
The 18 dimensioned configurations cover 26 AWG through 4/0 AWG. Each row combines UL 5359 with the conductor size and lists stranding, mica thickness, fiberglass-braid thickness and finished diameter. The wall schedule increases in steps as the conductor becomes larger, so the table supports both electrical size selection and the practical fit of sleeves, clamps and equipment entries.
For heater, oven or process-equipment wiring, choose the required temperature grade before comparing diameters. The 200°C and 450°C constructions are separate selections under the same style number. Installation should avoid repeated flexing and protect the mica-and-braid system from mechanical abuse. The operating current must be assessed for the selected conductor, ambient conditions, grouping and complete equipment application.
Tabele modeli i rozmiarów znajdują się w zakładce Specyfikacja. Przejrzyj kategorię gamę kabli wysokotemperaturowych dla powiązanych konstrukcji. Porównaj MGT mica-glass wire for the existing 5107/5128 lead wire construction.
Budowa
UL 5359 uses the following conductor and insulation system. The diagram illustrates the layer sequence; select the conductor construction and covering shown in the required size specification.

| Element | Szczegóły budowy |
|---|---|
| Żyła przewodząca | Stranded nickel-coated copper or nickel, selected for the required construction |
| Izolacja | Taśma mikowa |
| Powłoka zewnętrzna | Treated fiberglass braid |
Zastosowania
UL 5359 is used for protected internal leads in high-temperature equipment, including heaters and ovens. Keep the mica-insulated lead supported and avoid locations with repeated bending or rubbing.

UL 5359 replacement selection
Przy zapytaniu o zamiennik podaj oznaczenie dotychczasowego przewodu i rysunek połączeń urządzenia, aby można było dopasować żyłę, izolację i układ zacisków.
Dane techniczne
| Parametr | Specyfikacja |
|---|---|
| Styl UL | UL 5359 |
| Napięcie znamionowe | 600 V AC |
| Klasa temperaturowa | 200°C or 450°C by construction |
| Izolacja / warstwa ochronna | mica tape and treated fiberglass braid |
| Zakres rozmiarów żył | 30 AWG–4/0 AWG style range; table: 26 AWG–4/0 AWG |
| Temperature choices | 200°C or 450°C, according to construction |
| Napięcie znamionowe | 600 V AC |
| Instalacja | Protected internal wiring without repeated flexing |
450°C single-conductor dimensional reference. Nominal construction dimensions are for selection; the quotation drawing defines the supplied configuration.
| Model i rozmiar żyły | Liczba drutów żyły (szt./mm) | Mica wall (mm) | Braid wall (mm) | Nominalna średnica zewnętrzna / tolerancja (mm) |
|---|---|---|---|---|
| UL 5359 26 AWG | 7/0.16 | 0.41 | 0.18 | 1.8±0.1 |
| UL 5359 24 AWG | 7/0.2 | 0.41 | 0.18 | 1.9±0.1 |
| UL 5359 22 AWG | 7/0.254 | 0.41 | 0.18 | 2.1±0.2 |
| UL 5359 20 AWG | 10/0.254 | 0.41 | 0.18 | 2.2±0.2 |
| UL 5359 18 AWG | 16/0.254 | 0.41 | 0.18 | 2.5±0.2 |
| UL 5359 16 AWG | 26/0.254 | 0.41 | 0.18 | 2.8±0.2 |
| UL 5359 14 AWG | 41/0.254 | 0.41 | 0.18 | 3.2±0.3 |
| UL 5359 12 AWG | 65/0.254 | 0.41 | 0.18 | 3.6±0.3 |
| UL 5359 10 AWG | 103/0.254 | 0.51 | 0.38 | 5.1±0.5 |
| UL 5359 8 AWG | 163/0.254 | 0.51 | 0.38 | 6.0±0.5 |
| UL 5359 6 AWG | 260/0.254 | 0.51 | 0.38 | 7.1±0.5 |
| UL 5359 4 AWG | 413/0.254 | 0.51 | 0.38 | 8.2±0.5 |
| UL 5359 2 AWG | 168/0.5 | 0.64 | 0.51 | 10.5±0.8 |
| UL 5359 1 AWG | 212/0.5 | 0.64 | 0.51 | 11.5±0.8 |
| UL 5359 1/0 AWG | 268/0.5 | 0.64 | 0.51 | 12.7±0.8 |
| UL 5359 2/0 AWG | 342/0.5 | 0.64 | 0.51 | 14.0±0.8 |
| UL 5359 3/0 AWG | 430/0.5 | 0.64 | 0.51 | 15.4±0.8 |
| UL 5359 4/0 AWG | 538/0.5 | 0.64 | 0.51 | 17.0±0.8 |
Style construction thicknesses are shown in mils; 1 mil = 0.0254 mm. Nominal finished dimensions are listed separately.
| Model and conductor group | Minimum average mica wall (mils) | Minimum average treated braid (mils) |
|---|---|---|
| UL 5359 30–12 AWG | 16 | 7 |
| UL 5359 11–4 AWG | 20 | 15 |
| UL 5359 3–4/0 AWG | 25 | 20 |
Dobór wymaganej konstrukcji
Specify UL 5359, AWG, 600 V AC and the required 200°C or 450°C construction. The dimension table below applies to the 450°C mica/fiberglass version.
Normy
TEBAOFLEX UL 5359 wire is UL-certified appliance wiring material.
| Pozycja | Wymaganie lub odniesienie |
|---|---|
| Certyfikacja | AWM z certyfikatem UL |
| Oznaczenie stylu | UL 5359 |
| Norma konstrukcyjna | UL 758 — Materiały do okablowania urządzeń |
| Klasyfikacja palności stylu | Pozioma próba płomieniowa |
W specyfikacji zakupowej podaj styl UL, rozmiar żyły oraz klasę napięciową i temperaturową. Do zapytania dołącz wymaganą identyfikację produktu i dokumenty certyfikacyjne.
Poproś o dobór kabla i wycenę
Prześlij wymagane funkcje, długość kabla, warunki pracy mechanicznej, środowisko, zakończenia i ilość. Nasz zespół przeanalizuje zastosowanie przed przygotowaniem wyceny.
- Podaj nazwę produktu lub SKU oraz wymaganą długość kabla i ilość.
- Jeśli są dostępne, dołącz specyfikację, rysunek lub kartę katalogową.