H07G-U, H07G-R and H07G-K 450/750 V EVA Cables
H07G-U, H07G-R and H07G-K are 450/750 V EVA-insulated single-core cables for protected internal fixed wiring.
- H07G-U: Class 1 solid copper
- H07G-R: Class 2 stranded copper
- H07G-K: Class 5 flexible stranded copper
- Maximum operating temperature: +110°C
Request a quote with the required type, size, colour and length.
H07G-U, H07G-R and H07G-K EVA insulated cables
TEBAOFLEX H07G-U, H07G-R and H07G-K are 450/750 V single-core, high-temperature low-voltage power cables for fixed wiring in protected internal installations, including dry and clean environments. The three H07G cable types use EVA (ethylene vinyl acetate) rubber insulation, with a stated maximum operating temperature of +110°C. Select the conductor construction to suit the installation: H07G-U uses Class 1 solid copper, H07G-R Class 2 stranded copper and H07G-K Class 5 flexible stranded copper.
H07G-U, H07G-R and H07G-K share the supplied voltage and insulation platform but are not interchangeable solely by conductor size. H07G-K is intended where the installation route benefits from greater manoeuvrability; the final choice must account for the approved wiring method, bending, termination, protection, conductor class and applicable installation rules.
- Напряжение: 450/750 V.
- Изоляция: EVA rubber.
- Температура: +110°C maximum operating temperature; +250°C maximum conductor short-circuit temperature; +5°C minimum installation temperature.
- Стандартный справочник: EN 50525; flame retardant to IEC/EN 60332-1-2.
См. промышленный кабельный ассортимент for related products. Send the required H07G-U, H07G-R or H07G-K type, cross-section, colour, length and documentation requirements for a quotation.
Конструкция
The supplied construction image distinguishes the solid, stranded and flexible conductor formats within this H07G-U, H07G-R and H07G-K aggregate page.
| Тип | Дирижер | Изоляция | Напряжение |
|---|---|---|---|
| H07G-U | Class 1 solid copper | EVA rubber (ethylene vinyl acetate) | 450/750 В |
| H07G-R | Class 2 stranded copper | ||
| H07G-K | Class 5 flexible stranded copper |
Применения
H07G-U, H07G-R and H07G-K cables are supplied for fixed wiring in protected internal installations in dry, clean environments. Choose H07G-K where the stated Class 5 flexible construction helps with more complex installation routing; assess each route and termination against the project requirements.
- Confirm the installation method, conductor type and cross-section before ordering.
- Use the supplied temperature limits within the complete installation design.
- Specify H07G-U, H07G-R or H07G-K, insulation colour, length and required documentation in the enquiry.
Спецификации
H07G-U nominal data
| Область | Min. OD | Max. OD | Масса |
|---|---|---|---|
| 1,5 мм² | 2.8 mm | 3.5 mm | 25 kg/km |
| 2.5 mm² | 3,4 мм | 4,3 мм | 38 кг/км |
| 4 mm² | 4,0 мм | 5,0 мм | 57 kg/km |
| 6 mm² | 4,5 мм | 5,6 мм | 79 kg/km |
| 10 мм² | 5.7 mm | 7.1 mm | 129 кг/км |
H07G-R nominal data
| Область | Min. OD | Max. OD | Масса |
|---|---|---|---|
| 1,5 мм² | 2.9 | 3.7 | 25 |
| 2.5 mm² | 3.5 | 4.4 | 39 |
| 4 mm² | 4.2 | 5.2 | 58 |
| 6 mm² | 4.7 | 5.9 | 81 |
| 10 мм² | 6.0 | 7.4 | 131 |
| 16 мм² | 6.8 | 8.5 | 195 |
| 25 мм² | 8.4 | 10.6 | 301 |
| 35 мм² | 9.4 | 11.8 | 405 |
| 50 мм² | 10.9 | 13.7 | 571 |
| 70 мм² | 12.5 | 15.6 | 778 |
| 95 мм² | 14.5 | 18.1 | 1050 |
| 120 мм² | 15.9 | 19.9 | 1306 |
| 150 мм² | 17.7 | 22.1 | 1629 |
| 185 мм² | 19.7 | 24.6 | 2008 |
| 240 mm² | 22.4 | 28.0 | 2594 |
H07G-K nominal data
| Область | Min. OD | Max. OD | Масса |
|---|---|---|---|
| 1,5 мм² | 3.0 | 3.7 | 25 kg/km |
| 2.5 mm² | 3.6 | 4.5 | 39 kg/km |
| 4 mm² | 4.3 | 5.4 | 59 kg/km |
| 6 mm² | 4.8 | 6.0 | 81 kg/km |
| 10 мм² | 6.0 | 7.6 | 132 kg/km |
| 16 мм² | 7.1 | 8.9 | 197 kg/km |
| 25 мм² | 8.8 | 11.0 | 303 kg/km |
| 35 мм² | 10.1 | 12.6 | 410 kg/km |
| 50 мм² | 11.9 | 14.9 | 580 kg/km |
| 70 мм² | 13.6 | 17.0 | 788 kg/km |
| 95 мм² | 15.5 | 19.3 | 1060 кг/км |
| 120 мм² | 17.1 | 21.4 | 1318 kg/km |
| 150 мм² | 19.0 | 23.8 | 1645 kg/km |
| 185 мм² | 21.0 | 26.3 | 2026 kg/km |
| 240 mm² | 23.9 | 29.9 | 2615 kg/km |
Стандарты
| Product standard | EN 50525 |
|---|---|
| Flame retardance reference | IEC/EN 60332-1-2 |
| Other supplied statement | CPR compliant |
Варианты кабелей по теме
Сравните эти варианты кабелей по сочетанию услуг, типу перемещения, нагрузке, напряжению и требованиям к передаче.
Type G Cable 2 kV Portable Mining Power Cable
Аналогичный кабель предназначен для других областей применения или режимов работы.
Посмотреть товарType SHD-CGC 5 kV Shielded Portable Mining Power Cable
Аналогичный кабель предназначен для других областей применения или режимов работы.
Посмотреть товарNSHTOEU 0.6/1kV LHD Горнодобывающий кабель для намотки
Аналогичный кабель предназначен для других областей применения или режимов работы.
Посмотреть товарЗапросите рекомендации по выбору кабеля и коммерческое предложение.
Укажите необходимые услуги, длину кабеля, механические характеристики, условия эксплуатации, тип разъемов и количество. Наша команда рассмотрит заявку перед составлением коммерческого предложения.
- Укажите название продукта или артикул, а также необходимую длину кабеля и количество.
- При наличии приложите техническое задание, чертеж или спецификацию.