Получить ценовое предложение
КАБЕЛИ ДЛЯ ГОРНОДОБЫВАЮЩЕЙ ПРОМЫШЛЕННОСТИ И ПРОКЛАДКИ ТОННЕЛЕЙ ТЕБАОФЛЕКС

NSHCGEÖU KON+ST+UL 0.6/1 kV Monitored Tunnel Cable

0.6/1 kV monitored tunnel cable with concentric monitoring, earth conductors, flexible armour and UL certification obtained.

Информация о продукте
Бренд
ТЕБАОФЛЕКС
Обзор продукта

NSHCGEÖU KON+ST+UL is a 0.6/1 kV monitored tunnel cable for mobile coal-cutting and loading machines operating under high mechanical load. The supplied technical specification describes three tinned-copper power cores with 3GI3 EPR and semiconductive rubber insulation, control and monitoring cores, a double concentric arrangement, a GM1b inner sheath, a flexible helix of tinned copper and galvanized steel wires, and a yellow or red 5GM5 elastomer outer sheath. The concentric phase-monitoring screen and overall concentric earth conductor support insulation-fault and damage monitoring when connected to suitable equipment. The source lists 3 kV main-core testing, 2 kV control-core testing, 90 °C conductor operation, 250 °C short-circuit temperature, fixed service from −40 °C to +90 °C and mobile service from −25 °C to +90 °C. UL certification has been obtained, as confirmed for this product; the certificate record and scope should be supplied when required by the project. The page keeps the source configurations together so buyers can request one product while specifying the precise conductor arrangement and monitoring circuit needed for their machine. Confirm the KON/ST/UL core arrangement, monitoring interface, route, termination, mechanical load and final size with TEBAOFLEX.

Конструкция

NSHCGEÖU KON+ST+UL construction

The supplied construction is built around three power cores with double concentric control and monitoring cores. A concentric phase-monitoring screen and overall concentric earth conductor support insulation-fault and damage monitoring when used with suitable equipment.

NSHCGEÖU KON+ST+UL cable cross-section showing power cores, concentric monitoring and earth conductors, armour and rubber sheath
Supplied NSHCGEÖU KON+ST+UL cross-section showing the monitoring, earth-conductor and flexible-armour arrangement.
Construction identified in the supplied VDE datasheet
ПараметрЗначение по исходным данным
Power-core conductorTinned copper, DIN VDE 0295 class 5
Изоляция силового сердечника3GI3 EPR rubber and semi-rubber compound
Ядра управления/мониторингаTinned copper, DIN VDE 0295 class 5; 3GI3 EPR and semi-conductive rubber compound
бросокThree power cores with double concentric control cores and monitoring core in outer interstices
Внутренняя оболочкаGM1b type EPR compound
Screen / armourFlexible pliable armour in a helix of tinned copper and galvanised steel wires
Наружная оболочкаHeavy-duty elastomer 5GM5 type rubber compound, yellow or red

The monitoring and earth-conductor arrangement is a selection feature, not a substitute for the monitoring relay or protection-system design. Confirm core functions and termination continuity requirements before quotation.

Применения

Applications for NSHCGEÖU KON+ST+UL

The source positions this 0.6/1 kV monitored tunnel cable for mobile machines under very high mechanical load, especially coal-cutting and loading machines in mines. It also lists appliances, devices and auxiliary electrical circuits.

Underground coal-mining equipment with a flexible cable route in a wet mine environment
Existing Media Library image illustrating the underground mining context; confirm the actual monitoring equipment and cable route for this model.
  • Mobile coal-cutting and loading machines with the stated monitoring/earth arrangement
  • Appliances, devices and auxiliary electrical circuits in demanding mining and tunnel environments
  • Installations where a concentric phase-monitoring screen and overall earth conductor are connected to suitable monitoring equipment
  • Confirm site classification, monitoring interface, core schedule, termination, S-type changes and mechanical load before ordering

The source provides fixed and mobile temperature windows and a 20 × D S-type distance reference. Apply the project installation drawing and equipment protection requirements to the final selection.

Спецификации

NSHCGEÖU KON+ST+UL specifications

The following values are transcribed from the supplied two-page technical specification. The source lists two rows with the same nominal 3 × 70/35 KON configuration but different diameter and weight values; both rows are retained and the final construction must be confirmed before quotation.

NSHCGEÖU KON+ST+UL electrical and mechanical characteristics
ПараметрЗначение по исходным данным
Номинальное напряжение0,6/1 кВ
Maximum permissible AC operating voltage0,7/1,2 кВ
Maximum permissible DC operating voltage0,9/1,8 кВ
испытательное напряжение переменного тока3 кВ
AC test voltage for control cores2 кВ
Минимальный радиус изгибаСогласно DIN VDE 0298 Часть 3
Minimum distance with S-type directional changes20 × D
Current carrying capacityСогласно DIN VDE 0298-4
Working temperature — fixed−40 °C to +90 °C
Working temperature — mobile−25 °C to +90 °C
Maximum tensile load of cable15 Н/мм²
NSHCGEÖU KON+ST+UL dimensions and weight
Cross-section / core arrangementOverall diameter min–max (mm)Approx. weight (kg/km)
3 × 16/16 KON + (2 × 1.5 ST + 1.5 UL)35–382150
3 × 25/16 KON + (2 × 1.5 ST + 1.5 UL)41–463000
3 × 35/16 KON + (2 × 1.5 ST + 1.5 UL)42–473400
3 × 70/35 KON + (2 × 1.5 ST + 1.5 UL)46–514300
3 × 70/35 KON + (2 × 1.5 ST + 1.5 UL)52–565600
3 × 95/50 KON + (2 × 1.5 ST + 1.5 UL)58–627100
3 × 25/16 KON + 3 × (1.5 ST KON / 1.5 UL KON)42–463130
3 × 35/16 KON + 3 × (1.5 ST KON / 1.5 UL KON)43–473610
3 × 50/35 KON + 3 × (1.5 ST KON / 1.5 UL KON)49–534580
3 × 70/35 KON + 3 × (1.5 ST KON / 1.5 UL KON)52–565920
3 × 95/50 KON + 3 × (1.5 ST KON / 1.5 UL KON)60–647400
Стандарты

NSHCGEÖU KON+ST+UL standards and certification

The following standard references are taken from the supplied technical specification. The UL certification status is included because it was expressly confirmed for this product by the user.

Standards, tests and approvals referenced for this product
ПараметрЗначение по исходным данным
UL certificationObtained
КонструкцияDIN VDE 0250-812
General requirementsDIN VDE 0250-1
Guide useDIN VDE 0298-3
Electrical testsDIN VDE 0472-501, 503, 508
Non-electrical testsDIN VDE 0472-401, 402, 602, 303, 615
Under-fire-condition testsDIN VDE 0472-803, 804
ОгнестойкийVDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1
Oil resistantHD/EN/IEC 60811-2-1 / DIN VDE 0473-811-2-1

Provide the applicable UL certificate record and project acceptance scope with the RFQ when required. The public page does not invent a certificate number or approval scope.

Сравнение по пошлинам

Варианты кабелей по теме

Сравните эти варианты кабелей по сочетанию услуг, типу перемещения, нагрузке, напряжению и требованиям к передаче.

Коммерческое предложение, составленное инженерами

Запросите рекомендации по выбору кабеля и коммерческое предложение.

Укажите необходимые услуги, длину кабеля, механические характеристики, условия эксплуатации, тип разъемов и количество. Наша команда рассмотрит заявку перед составлением коммерческого предложения.

  • Укажите название продукта или артикул, а также необходимую длину кабеля и количество.
  • При наличии приложите техническое задание, чертеж или спецификацию.

    Необязательно: прикрепите спецификацию кабеля, чертёж, паспорт или изображение изделия (PDF, DOC, DOCX, XLS, XLSX, CSV, JPG или PNG; максимум 10 МБ).

    Эти ссылки и сведения об испытаниях взяты из предоставленного комплекта документации. Формулировки сохранены в соответствии с источником: ссылка на стандарт или метод испытаний не представляется сертификатом изделия, если источник прямо так её не называет. Ссылка / позиция Предоставленная формулировка

    SAE J1128