NSHCGEÖU KON+ST+UL 0.6/1 kV Monitored Tunnel Cable
0.6/1 kV monitored tunnel cable with concentric monitoring, earth conductors, flexible armour and UL certification obtained.
NSHCGEÖU KON+ST+UL is a 0.6/1 kV monitored tunnel cable for mobile coal-cutting and loading machines operating under high mechanical load. The supplied technical specification describes three tinned-copper power cores with 3GI3 EPR and semiconductive rubber insulation, control and monitoring cores, a double concentric arrangement, a GM1b inner sheath, a flexible helix of tinned copper and galvanized steel wires, and a yellow or red 5GM5 elastomer outer sheath. The concentric phase-monitoring screen and overall concentric earth conductor support insulation-fault and damage monitoring when connected to suitable equipment. The source lists 3 kV main-core testing, 2 kV control-core testing, 90 °C conductor operation, 250 °C short-circuit temperature, fixed service from −40 °C to +90 °C and mobile service from −25 °C to +90 °C. UL certification has been obtained, as confirmed for this product; the certificate record and scope should be supplied when required by the project. The page keeps the source configurations together so buyers can request one product while specifying the precise conductor arrangement and monitoring circuit needed for their machine. Confirm the KON/ST/UL core arrangement, monitoring interface, route, termination, mechanical load and final size with TEBAOFLEX.
NSHCGEÖU KON+ST+UL construction
The supplied construction is built around three power cores with double concentric control and monitoring cores. A concentric phase-monitoring screen and overall concentric earth conductor support insulation-fault and damage monitoring when used with suitable equipment.

| Parameter | Source-listed value |
|---|---|
| Power-core conductor | Tinned copper, DIN VDE 0295 class 5 |
| Power-core insulation | 3GI3 EPR rubber and semi-rubber compound |
| Control / monitoring cores | Tinned copper, DIN VDE 0295 class 5; 3GI3 EPR and semi-conductive rubber compound |
| Lay-up | Three power cores with double concentric control cores and monitoring core in outer interstices |
| Inner sheath | GM1b type EPR compound |
| Screen / armour | Flexible pliable armour in a helix of tinned copper and galvanised steel wires |
| Outer sheath | Heavy-duty elastomer 5GM5 type rubber compound, yellow or red |
The monitoring and earth-conductor arrangement is a selection feature, not a substitute for the monitoring relay or protection-system design. Confirm core functions and termination continuity requirements before quotation.
Applications for NSHCGEÖU KON+ST+UL
The source positions this 0.6/1 kV monitored tunnel cable for mobile machines under very high mechanical load, especially coal-cutting and loading machines in mines. It also lists appliances, devices and auxiliary electrical circuits.

- Mobile coal-cutting and loading machines with the stated monitoring/earth arrangement
- Appliances, devices and auxiliary electrical circuits in demanding mining and tunnel environments
- Installations where a concentric phase-monitoring screen and overall earth conductor are connected to suitable monitoring equipment
- Confirm site classification, monitoring interface, core schedule, termination, S-type changes and mechanical load before ordering
The source provides fixed and mobile temperature windows and a 20 × D S-type distance reference. Apply the project installation drawing and equipment protection requirements to the final selection.
NSHCGEÖU KON+ST+UL specifications
The following values are transcribed from the supplied two-page technical specification. The source lists two rows with the same nominal 3 × 70/35 KON configuration but different diameter and weight values; both rows are retained and the final construction must be confirmed before quotation.
| Parameter | Source-listed value |
|---|---|
| Rated voltage | 0.6/1 kV |
| Maximum permissible AC operating voltage | 0.7/1.2 kV |
| Maximum permissible DC operating voltage | 0.9/1.8 kV |
| AC test voltage | 3 kV |
| AC test voltage for control cores | 2 kV |
| Minimum bending radius | According to DIN VDE 0298 Part 3 |
| Minimum distance with S-type directional changes | 20 × D |
| Current carrying capacity | According to DIN VDE 0298-4 |
| Working temperature — fixed | −40 °C to +90 °C |
| Working temperature — mobile | −25 °C to +90 °C |
| Maximum tensile load of cable | 15 N/mm² |
| Cross-section / core arrangement | Overall diameter min–max (mm) | Approx. weight (kg/km) |
|---|---|---|
| 3 × 16/16 KON + (2 × 1.5 ST + 1.5 UL) | 35–38 | 2150 |
| 3 × 25/16 KON + (2 × 1.5 ST + 1.5 UL) | 41–46 | 3000 |
| 3 × 35/16 KON + (2 × 1.5 ST + 1.5 UL) | 42–47 | 3400 |
| 3 × 70/35 KON + (2 × 1.5 ST + 1.5 UL) | 46–51 | 4300 |
| 3 × 70/35 KON + (2 × 1.5 ST + 1.5 UL) | 52–56 | 5600 |
| 3 × 95/50 KON + (2 × 1.5 ST + 1.5 UL) | 58–62 | 7100 |
| 3 × 25/16 KON + 3 × (1.5 ST KON / 1.5 UL KON) | 42–46 | 3130 |
| 3 × 35/16 KON + 3 × (1.5 ST KON / 1.5 UL KON) | 43–47 | 3610 |
| 3 × 50/35 KON + 3 × (1.5 ST KON / 1.5 UL KON) | 49–53 | 4580 |
| 3 × 70/35 KON + 3 × (1.5 ST KON / 1.5 UL KON) | 52–56 | 5920 |
| 3 × 95/50 KON + 3 × (1.5 ST KON / 1.5 UL KON) | 60–64 | 7400 |
NSHCGEÖU KON+ST+UL standards and certification
The following standard references are taken from the supplied technical specification. The UL certification status is included because it was expressly confirmed for this product by the user.
| Parameter | Source-listed value |
|---|---|
| UL certification | Obtained |
| Construction | DIN VDE 0250-812 |
| General requirements | DIN VDE 0250-1 |
| Guide use | DIN VDE 0298-3 |
| Electrical tests | DIN VDE 0472-501, 503, 508 |
| Non-electrical tests | DIN VDE 0472-401, 402, 602, 303, 615 |
| Under-fire-condition tests | DIN VDE 0472-803, 804 |
| Flame retardant | VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1 |
| Oil resistant | HD/EN/IEC 60811-2-1 / DIN VDE 0473-811-2-1 |
Provide the applicable UL certificate record and project acceptance scope with the RFQ when required. The public page does not invent a certificate number or approval scope.
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
NSSHKCGEOEU 0.6/1kV Coal Cutter Trailing Cable
A related cable option for a different application or duty profile.
View productNSSHCGEOEU 0.6/1kV High-Tensile Reeling Mining Cable
A related cable option for a different application or duty profile.
View product(N)SSHCGEWÖU-V Cable 0.6/1kV for Coal Mine Cutters and Drills
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.