UL 3580 Silicone Motor Lead Wire, 150°C 1000V
UL 3580 is a UL-certified silicone motor lead wire rated 150°C and 1000 V AC. It is intended for motor leads and internal appliance or electronic equipment wiring where the lead is protected from mechanical abuse.
- Voltaje: 1000 V AC
- Temperatura: 150°C
- Aislamiento / cubierta: extruded silicone rubber
- Selección de tamaño: 26 AWG–500 kcmil style range; table: 26–6 AWG
- Certificación: AWM con certificación UL; UL 758
UL 3580 wire selection
UL 3580 is a UL-certified silicone motor lead wire rated 150°C and 1000 V AC. It is intended for motor leads and internal appliance or electronic equipment wiring where the lead is protected from mechanical abuse.
The detailed size table covers 26–6 AWG. Nominal silicone thickness is 1.20 mm in the 26–10 AWG rows and 1.58 mm in the 8–6 AWG rows. Conductor stranding and finished diameter are listed with each model-size combination to help check motor terminal entries, connection boxes and protective sleeves. A separate insulation schedule explains the larger conductor groups within the style range.
For a motor connection, allow space for the finished wire rather than selecting the entry around the bare conductor size. The listed construction uses a bend radius of 10 times its finished diameter. Check the temperature near the winding exit and at the connection hardware, because the 150°C wire rating must be compatible with the rest of the assembly.
Consulte la pestaña Especificaciones para ver las tablas de modelos y calibres. Explore la gama de cables de alta temperatura for related constructions. Compare UL 3644 for a different 1 kV wall schedule and the cables de conexión de silicona for lower-voltage options.
Construcción
UL 1056 utiliza el sistema de conductor y aislamiento que se muestra a continuación. El diagrama indica el orden de las capas; seleccione la construcción del conductor y la cubierta que figuran en la especificación del calibre requerido.

| Componente | Detalle de construcción |
|---|---|
| Conductor | Solid or stranded copper; dimensioned examples are stranded |
| Aislamiento | Caucho de silicona extruido |
Aplicaciones
UL 3580 is used as motor lead wire and for internal appliance or electronic equipment wiring. Route and support the lead to prevent rubbing or mechanical damage at the winding exit and terminal enclosure.

UL 3580 replacement selection
Para solicitar un repuesto, envíe el marcado del cable existente y el plano de conexión del equipo. Así se podrán comparar el conductor, el aislamiento y la disposición de los terminales.
Especificaciones
| Parámetro | Especificación |
|---|---|
| Estilo UL | UL 3580 |
| Tensión nominal | 1000 V AC |
| Clasificación de temperatura | 150°C |
| Aislamiento / revestimiento | extruded silicone rubber |
| Rango de calibres del conductor | 26 AWG–500 kcmil style range; table: 26–6 AWG |
| Bending radius for listed construction | 10 × finished OD |
Nominal dimensions follow the listed conductor constructions. Confirm the agreed finished-diameter drawing for tight-clearance assemblies.
| Modelo y calibre del conductor | Hilos del conductor (n.º/mm) | Nominal silicone wall (mm) | Diámetro exterior nominal / tolerancia (mm) |
|---|---|---|---|
| UL 3580 6 AWG | 259/0.254 | 1.58 | 7.89 ±0.10 |
| UL 3580 8 AWG | 161/0.254 | 1.58 | 6.88 ±0.10 |
| UL 3580 10 AWG | 105/0.254 | 1.20 | 5.41 ±0.10 |
| UL 3580 12 AWG | 65/0.254 | 1.20 | 4.77 ±0.10 |
| UL 3580 14 AWG | 41/0.254 | 1.20 | 4.28 ±0.10 |
| UL 3580 16 AWG | 26/0.254 | 1.20 | 3.90 ±0.10 |
| UL 3580 18 AWG | 34/0.18 | 1.20 | 3.62 ±0.10 |
| UL 3580 20 AWG | 21/0.18 | 1.20 | 3.36 ±0.10 |
| UL 3580 22 AWG | 17/0.16 | 1.20 | 3.17 ±0.10 |
| UL 3580 24 AWG | 11/0.16 | 1.20 | 3.02 ±0.10 |
| UL 3580 26 AWG | 7/0.16 | 1.20 | 2.89 ±0.10 |
Style construction thicknesses are shown in mils; 1 mil = 0.0254 mm. Nominal finished dimensions are listed separately.
| Model and conductor group | Minimum average silicone wall (mils) | Minimum point wall (mils) |
|---|---|---|
| UL 3580 26–9 AWG | 45 | 40 |
| UL 3580 8–2 AWG | 60 | 54 |
| UL 3580 1–4/0 AWG | 80 | 72 |
| UL 3580 250–500 kcmil | 95 | 86 |
Selección de la construcción especificada
Specify UL 3580 with AWG or kcmil, stranding, required OD and connection temperature. For a size outside the dimension table, use the insulation schedule as a starting point and request the corresponding drawing.
Normas
TEBAOFLEX UL 3580 wire is UL-certified appliance wiring material.
| Artículo | Requisito o referencia |
|---|---|
| Certificación | AWM con certificación UL |
| Designación del estilo | UL 3580 |
| Norma de construcción | UL 758 — Material de cableado para aparatos |
| Clasificación de inflamabilidad del estilo | Llama horizontal |
Indique el estilo UL, el calibre del conductor y los valores de tensión y temperatura en la especificación de compra. Incluya en la consulta la identificación del producto y los documentos de certificación requeridos.
Solicite una recomendación y un presupuesto de cables.
Indique los servicios requeridos, la longitud del cable, la carga mecánica, el entorno, el tipo de terminación y la cantidad. Nuestro equipo revisará la solicitud antes de elaborar un presupuesto.
- Incluya el nombre del producto o SKU, así como la longitud y la cantidad de cable requeridas.
- Adjunte una especificación, un dibujo o una hoja de datos cuando esté disponible.