Type G Cable 2 kV Portable Mining Power Cable

Type G Cable is a 2,000 V portable power cable for stated industrial and mining applications requiring grounding.

  • Chefs d'orchestre : flexible stranded bare or tin-coated copper
  • Isolation: colour-coded 90°C EPDM
  • Ground wires: green EPDM-insulated copper
  • Veste: flame-retardant, oil- and sunlight-resistant CPE
  • Gamme de tailles : 8 AWG to 500 MCM

Request Type G Mining Cable pricing with the conductor count, gauge, length and application details.

Informations sur le produit
Marque
Modèle / construction
Présentation du produit

Type G Cable 2 kV portable mining power cable

TEBAOFLEX Type G Cable is a 2,000 V portable power cable for three- and four-wire AC systems requiring grounding. The supplied Type G Mining Cable information identifies industrial and mining uses, including mining equipment, cranes, conveyors, mobile equipment, electromagnets and oil-drilling equipment. Its stated design combines flexible annealed stranded copper conductors, colour-coded EPDM insulation, multiple insulated grounding conductors and a reinforced thermoset CPE jacket.

The Type G Cable configuration uses the same number of ground wires as primary conductors. The supplied information states that the total ground-wire cross-sectional area is roughly equal to that of the primary conductors. This arrangement, along with the supplied EPDM insulation and CPE outer jacket, is intended for portable cable duties exposed to heat, acids, oil, moisture and demanding environmental conditions.

  • Tension nominale : 2,000 V.
  • Plage de températures : −40°C to +90°C.
  • Available construction: three or four pure stranded copper phase conductors with three or four green ground wires.
  • Gamme de tailles : 8 AWG to 500 MCM.

For the final Type G Mining Cable selection, confirm conductor count, size, equipment connection, route, ambient conditions, required approvals, length and documentation. Explore the gamme de câbles pour l'exploitation minière et le creusement de tunnels for related portable cable constructions.

Construction

Type G Cable construction

The supplied Type G Cable design uses flexible copper phase conductors and matching green grounding conductors within EPDM insulation and a reinforced CPE outer jacket.

Type G Cable cutaway showing coloured insulated copper conductors, green grounding conductors and black CPE jacket
Type G Cable construction view; final core count and configuration follow the approved order drawing.
Élément de constructionSupplied Type G Mining Cable reference
conducteurs de phaseFully annealed stranded bare or tin-coated copper; rope-lay stranding for flexibility
IsolationPremium-grade colour-coded 90°C ethylene-propylene-diene monomer (EPDM)
Ground conductorsGreen EPDM-insulated bare or tinned copper stranding; same number as primary conductors
Ground-wire areaTotal area stated as roughly equal to the primary-conductor cross-sectional area
Gaine extérieureFlame-retardant, oil- and sunlight-resistant chlorinated polyethylene (CPE), rated 90°C
OptionsOther sizes, colours and custom designs on request; EPR available on request
Applications

Applications

Type G Mining Cable is supplied for portable power duties on three- and four-wire AC systems requiring grounding. The supplied applications include mining equipment, cranes, conveyors, mobile equipment, electromagnets and oil-drilling equipment. Type G Cable is also described for temporary power supply duty in industrial and mining use.

Type G Mining Cable connected to underground mining equipment in a wet mine environment
Underground mobile-equipment connection illustrating a Type G Mining Cable application.

Selection checks

  • Confirm whether a three- or four-conductor Type G Cable configuration is required, together with the grounding arrangement.
  • Check the conductor size against load, voltage drop, route, protective device and installation conditions.
  • Review exposure to impact, abrasion, heat, acids, oil, moisture and weather with the actual site engineering requirements.
  • Specify the required length, colour code, jacket option, approvals and documentation with the enquiry.

The supplied Type G Cable construction is not interchangeable with Type G-GC or Type GC cable arrangements: confirm the required ground and ground-check functions before final selection.

Caractéristiques

Type G Cable specifications

The following nominal four-conductor Type G Cable data is transcribed from the supplied information. All dimensions are nominal and subject to normal manufacturing tolerance.

Taille du conducteurNo. of conductorsÉchouageGround conductorépaisseur de l'isolantApprox. diameterNet weight
8 AWG41334 × 12 AWG1.520 mm (0.060 in)26.540 mm (1.045 in)945 kg/km (635 lb/MFT)
6 AWG42594 × 12 AWG1.520 mm (0.060 in)28.580 mm (1.125 in)1,339 kg/km (900 lb/MFT)
4 AWG42594 × 10 AWG1.520 mm (0.060 in)30.730 mm (1.210 in)1,905 kg/km (1,280 lb/MFT)
2 AWG42594 × 9 AWG2.030 mm (0.080 in)36.450 mm (1.435 in)2,976 kg/km (2,000 lb/MFT)
1/0 AWG42594 × 7 AWG2.030 mm (0.080 in)43.69 mm (1.720 in)4,672 kg/km (3,140 lb/MFT)
2/0 AWG42594 × 6 AWG2.030 mm (0.080 in)47.240 mm (1.860 in)5,625 kg/km (3,780 lb/MFT)
3/0 AWG42594 × 5 AWG2.030 mm (0.080 in)52.710 mm (2.075 in)6,696 kg/km (4,500 lb/MFT)
4/0 AWG42594 × 5 AWG2.030 mm (0.080 in)54.740 mm (2.155 in)8,214 kg/km (5,520 lb/MFT)
500 MCM41,2354 × 1/0 AWG2.413 mm (0.095 in)86.400 mm (3.400 in)16,008 kg/km (10,758 lb/MFT)

Additional supplied size references

Taille du conducteurÉchouageGround conductorépaisseur de l'isolantdiamètre extérieurMaterial weight
250 kcmil4274 × 3 AWG0.095 in2.77 in7,143 lb/M
350 kcmil8884 × 2 AWG0.095 in3.10 in6,567 lb/M

For shared sizes, source tables supplied for this page show differing nominal weights and dimensions. Confirm the approved manufacturing drawing and final quotation data before ordering.

Normes

Standards and supplied approval references

The supplied Type G Cable information lists the following standards and approval/compliance references.

NormesCSA FT5; ASTM B172 and B33; MSHA P-7K-268101; ICEA S-75-381 / NEMA WC-58; ICEA S-68-516 / NEMA WC-8
Flame-test referencesMSHA P-122 MSHA flame-resistance; UL 1581 vertical tray flame test
Portable power cable referenceUL 1650 Portable Power Cable
Other supplied referencesCSA approved; MSHA listed; RoHS compliant

State the required standard edition, approval scope, test report and documentation requirements in the enquiry.

Comparer par fonction

Options de câbles associées

Comparez ces options de câbles en fonction de la combinaison de services, du mouvement, de la charge, de la tension et des exigences de transmission.

devis basé sur l'ingénierie

Demandez une recommandation et un devis pour un câble.

Veuillez nous indiquer les services requis, la longueur du câble, les contraintes mécaniques, l'environnement, le type de terminaison et la quantité. Notre équipe examinera votre demande avant de vous établir un devis.

  • Veuillez inclure le nom du produit ou son SKU, ainsi que la longueur et la quantité de câble requises.
  • Joignez une fiche technique, un dessin ou une fiche de spécifications si disponible.

    Facultatif : joindre une spécification de câble, un dessin, une fiche technique ou une image du produit (PDF, DOC, DOCX, XLS, XLSX, CSV, JPG ou PNG ; maximum 10 Mo).

    En soumettant ce formulaire, vous acceptez que TEBAOFLEX utilise vos coordonnées et les fichiers fournis pour examiner votre demande et y répondre. Les fichiers servent à l'établissement du devis et aux échanges techniques relatifs à votre demande. Consultez notre politique de confidentialité. politique de confidentialité pour obtenir des informations à jour sur le traitement et la conservation des données.

    * Champs obligatoires. Veuillez inclure les détails du câble principal ou de l'application pour examen.