Type 621 BS 6708 3800/6600 V Armoured Mining Cable
Type 621 mining cable for excavating and crushing machines in deep mines and on the surface, with the source-defined 3800/6600 V rating and 15 kV test reference.
- Model: Type 621
- Conductor and insulation: flexible tinned copper with the insulation and core construction listed for this model in the supplied PDF
- Screen, pilot, earth and armour arrangement preserved from the source datasheet
- Heavy-duty chloroprene or PCP outer protection as listed for this model
- Original Type datasheet available as the product download
Send the equipment, voltage, conductor area, route, quantity and document requirements for an RFQ.
Type 621 for excavating and crushing machines in deep mines and on the surface
Type 621 mining cable is specified in the supplied BS 6708 datasheet for excavating and crushing machines in deep mines and on the surface. This page keeps the source-listed voltage, test reference, core functions and dimensional tables together so a procurement engineer can compare the requested model against the cable marking and the equipment connection. The editorial focus is the unscreened-core armoured 6.6 kV selection, not a generic promise of performance.
The supplied construction uses three phase cores and one pilot core, all unscreened, laid up in contact with one another and protected by galvanized steel pliable armour between inner and outer sheaths. That arrangement matters because Type 621 is armoured and unscreened; it is therefore a different construction path from individually screened Type 630/631 and Type 730. The family should therefore be selected by model, core function and installation route as well as by voltage. The gamme de câbles pour l'exploitation minière et le creusement de tunnels provides the wider TEBAOFLEX product context.
- Choisir par : confirm that the machine design accepts the unscreened three-phase and pilot arrangement before comparing Type 621 with Type 630 or Type 730.
- Confirmez avant de commander : existing sheath marking, conductor area, cable length, route, support or handling system, terminations and the required inspection documents.
- Do not infer: values not listed in the supplied PDF, such as a different current basis, water/oil/UV performance, certification scope or mechanical interchangeability.
For a project review that includes equipment connection, cable handling and documentation, use the Mining & Tunnelling solutions page as a planning companion to this Type 621 data.
For a technical quotation, send the equipment nameplate or existing cable marking, voltage and size requirement, installation conditions, quantity, destination and any project-specific test or documentation requirement.
Type 621 construction
The cross-section below is the supplied construction drawing for Type 621. The ordering decision is driven by Type 621 is armoured and unscreened; it is therefore a different construction path from individually screened Type 630/631 and Type 730.

Source-listed construction
| Élément de construction | Valeur indiquée dans la source |
|---|---|
| Conducteur | Electrolytic stranded tinned copper wire, IEC 60228 Class 5 |
| Isolation | Isolation EPR |
| Lay-up | Cores laid up over each other |
| Armure | blindage souple en acier galvanisé |
| Gaine | Heavy-duty chloroprene outer sheath |
| Agencement de base | Three phase cores and one pilot core, all unscreened, laid up in contact; pliable armour between inner and outer sheaths |
Do not use the drawing as a substitute for the dimensional tables. Confirm the cable end preparation, screen and earth termination, armour bonding and machine interface with the equipment documentation before installation.
Type 621 applications

The supplied datasheet identifies this cable for excavating and crushing machines in deep mines and on the surface. Google result patterns for the BS 6708 family also separate cables by equipment duty, voltage class, core function and whether the route is armoured, screened, flat or auxiliary. That is why this page keeps the Type 621 construction separate from nearby Type numbers.
- Primary duty: excavating and crushing machines in deep mines and on the surface.
- Model boundary: Type 621 is armoured and unscreened; it is therefore a different construction path from individually screened Type 630/631 and Type 730.
- Project check: match the cable marking, core map, voltage, termination, route geometry and handling method to the machine drawing.
- Environmental review: confirm the actual mine/quarry conditions and any authority, inspection or documentation requirements; do not infer a certification or material-resistance claim from the model number.
For projects evaluating the paired Type 630/631 construction, see the Type 630/631 armoured mining cable page and compare the source-listed core and armour details.
The cable should be released only after the equipment route, required length, conductor area, core functions and connection details are agreed. If the intended duty is different from the source-listed application, request an engineering review through the quotation process.
Type 621 specifications
The summary below identifies the supplied model family. The source-transcribed tables that follow retain the PDF's dimensional, electrical and construction values, including available sizes, resistance, current, diameter, mass, bending or pulling data when the PDF provides them.
| Selection item | Source-linked value |
|---|---|
| Modèle | Type 621 |
| Tension nominale | 3800/6600 V |
| Tension d'essai | 15 kV |
| Application | excavating and crushing machines in deep mines and on the surface |
| Norme du produit | BS 6708 |
Complete source-transcribed technical tables
Source PDF: BS6708_TYPE_621_3800_6600V_ARMOURED_POWER_CABLE_datasheet.pdf; 3 pages; 6 extracted tables. Values are not recalculated or replaced by third-party values.
| Paramètre | Valeur |
|---|---|
| Conducteur | Electrolytic, stranded, tinned copper wire, IEC 60228 Class 5 |
| Isolation | EPR |
| Lay-up | Cores are laid up over each other |
| Literie | Rubber based bedding compound |
| Armure | blindage souple en acier galvanisé |
| Gaine extérieure | Heavy duty chloroprene outer sheath |
| Paramètre | Valeur |
|---|---|
| Standard | BS 6708 |
| Tension nominale | 3800/6600 V |
| Tension d'essai | 15 kV |
| Type de câble | Three phase cores and one pilot core, all unscreened, laid up in contact with each other; pliable armour between inner and outer sheaths |
| CORE DIMENSIONS | ||||
|---|---|---|---|---|
| Nominal cross section | Conducteurs | Stranding mm | Conductor diameter mm | Insulation thickness mm |
| 4x35 | 4x35 | 276/0.40 | 8.40 | 5.0 |
| 4x50 | 4x50 | 396/0.40 | 10.10 | 5.0 |
| 4x70 | 4x70 | 360/0.50 | 11.90 | 5.0 |
| 4x95 | 4x95 | 475/0.50 | 13.90 | 5.0 |
| 4x120 | 4x120 | 608/0.50 | 15.50 | 5.0 |
| 4x150 | 4x150 | 756/0.50 | 17.20 | 5.0 |
| CABLE DETAILS | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Nominal Ecross section | Inner sheath thickness mm | Min. inner sheath dia. mm | Max. inner sheath dia. mm | Armour size mm | Outer sheath thickness mm | Min. OD mm | Max. OD mm | Min. bend radius mm | Approx. weight kg/km | Copper weight kg/km |
| 4x35 | 3.8 | 53.8 | 56.8 | 7/0.90 | 6.0 | 71.2 | 75.2 | 752 | 8900 | 1350 |
| 4x50 | 5.0 | 60.5 | 63.5 | 7/1.25 | 6.3 | 81.0 | 85.3 | 853 | 11100 | 1950 |
| 4x70 | 5.0 | 65.6 | 69.4 | 7/1.25 | 7.0 | 87.1 | 91.4 | 914 | 13000 | 2700 |
| 4x95 | 5.0 | 70.7 | 74.5 | 7/1.25 | 7.5 | 93.2 | 97.5 | 975 | 14050 | 3700 |
| 4x120 | 5.0 | 74.3 | 78.1 | 7/1.25 | 7.8 | 97.4 | 101.7 | 1017 | 20600 | 4650 |
| 4x150 | 5.0 | 79.2 | 83.2 | 7/1.25 | 8.3 | 103.3 | 107.6 | 1076 | 22000 | 5800 |
| CURRENT RATINGS | |
|---|---|
| Nominal cross section | Continuous current rating at 25 deg C |
| 4x35 | 135 |
| 4x50 | 170 |
| 4x70 | 205 |
| 4x95 | 250 |
| 4x120 | 295 |
| 4x150 | 320 |
| ELECTRICAL DETAILS | ||
|---|---|---|
| Nominal cross section | Conductors Max. DC res. at 20 deg C ohm/km | Armour Max. DC res. at 20 deg C ohm/km |
| 4x35 | 0.565 | 0.70 |
| 4x50 | 0.393 | 0.50 |
| 4x70 | 0.277 | 0.43 |
| 4x95 | 0.210 | 0.39 |
| 4x120 | 0.164 | 0.38 |
| 4x150 | 0.132 | 0.35 |
Use the table values with the equipment drawing and approved termination plan. If the requested conductor area, current basis, mechanical limit or environmental condition is not listed in the supplied PDF, treat it as a quotation-stage confirmation item.
Type 621 standards and references
| Objet | Source-linked reference |
|---|---|
| Norme du produit | BS 6708 |
| Tension nominale | 3800/6600 V |
| Tension d'essai | 15 kV |
| Source application | excavating and crushing machines in deep mines and on the surface |
The product page preserves the BS 6708 reference appearing in the supplied PDF. The BSI record currently identifies BS 6708:1998 as withdrawn on 22 May 2026; this status note is a standards-reference update, not a claim that the product is currently certified or approved. See the official BSI BS 6708 scope record for the published status.
For an RFQ, state the required standard documents, inspection scope, test report, cable marking, destination rules and any replacement-equivalence requirement. The model number alone does not establish legal installation compliance.
Options de câbles associées
Comparez ces options de câbles en fonction de la combinaison de services, du mouvement, de la charge, de la tension et des exigences de transmission.
Type 245 Flexible Rubber Mining Cable 1.1–6.6 kV
Une option de câble similaire pour une application ou un profil de service différent.
Voir le produitCâble d'alimentation blindé pour l'industrie minière TYPE260
Une option de câble similaire pour une application ou un profil de service différent.
Voir le produitCâble souterrain pour mine de charbon de type 240, 1,1 kV à 11 kV
Une option de câble similaire pour une application ou un profil de service différent.
Voir le produitDemandez une recommandation et un devis pour un câble.
Veuillez nous indiquer les services requis, la longueur du câble, les contraintes mécaniques, l'environnement, le type de terminaison et la quantité. Notre équipe examinera votre demande avant de vous établir un devis.
- Veuillez inclure le nom du produit ou son SKU, ainsi que la longueur et la quantité de câble requises.