Type 455 Class 1 Semiconductive Screened Mining Cable 3.3/3.3–11/11 kV
Type 455 mining cable is a Class 1 semiconductive screened 3.3/3.3–11/11 kV cable for reeling and trailing service.
- Three XR-EP-90 semiconductive screened power cores
- Two elastomer-covered earth conductors and one pilot
- Extra-heavy XHD-85-PCP sheath with polyaramid braid
- For draglines, shovels, excavators, cranes and material handling
- Separate comparison route from composite-screened Type 450/451
- +90 °C continuous operating; −25 °C minimum installation
Provide the voltage, area and route details for a Type 455 review.
Type 455 mining cable without a composite insulation screen
Type 455 mining cable is the Class 1 semiconductive-screened option in this voltage group. The supplied datasheet covers 3.3/3.3, 6.6/6.6 and 11/11 kV and describes a three-power-core, two-earth, one-pilot construction for reeling and trailing service. It is listed for draglines, shovels, excavators, wharf cranes and materials-handling equipment.
The useful comparison point is construction: Type 455 uses XR-EP-90 semiconductive screened power cores, two elastomer-covered tinned earth conductors and one elastomer-covered tinned pilot. Unlike the composite-screened Type 450/451 family, this source sheet describes a semiconductive screened cable without that composite insulation-screen arrangement. The outer layer is an extra-heavy XHD-85-PCP sheath with polyaramid braid.
Select the exact voltage and area from the tables, then confirm the termination, earth/pilot functions and handling method. A model-number match does not establish mechanical interchangeability; current capacity, bend radius, pulling load and travel speed are not stated in the PDF and must be confirmed separately. Keep the cable schedule and reel data together during approval, including reel access and cable-entry clearances.
Type 455 semiconductive screened construction
Type 455 keeps the core arrangement simple and explicit: three screened power cores, two earth conductors and one pilot. Its product-specific comparison point is the semiconductive screened construction rather than the composite screen described for Type 450 and Type 451.

| Paramètre | Valeur indiquée dans la source |
|---|---|
| Noyaux énergétiques | Three tinned copper cores with XR-EP-90 semiconductive elastomer screen |
| conducteurs de terre | Two elastomer-covered tinned earth cores |
| Pilot | One elastomer-covered tinned pilot |
| Identification du noyau | Numbered cores |
| Gaine | Extra-heavy XHD-85-PCP with polyaramid braid |
| Agencement de base | 3 power + 2 earth + 1 pilot |
The supplied cross-section is placed here to show the six-core arrangement. Confirm the screen termination and earth/pilot circuit before treating another Type 455 size as a replacement.
Type 455 reeling and trailing use
The source describes Type 455 for slow reeling and trailing on mobile surface-mining and materials-handling equipment. The buyer should use the construction distinction to guide comparisons with composite-screened families.
- Draglines, shovels and excavators
- Wharf cranes and materials-handling equipment
- Slow reeling or trailing routes for the 3.3/3.3–11/11 kV range
- Equipment requiring two earth conductors and one pilot through the termination
Verify cable-management geometry, termination hardware and project mechanical limits; the source does not state a minimum bend radius, permitted pull or travel speed.
Type 455 Class 1 Semiconductive Screened Mining Cable 3.3/3.3–11/11 kV technical data
The dimensional and electrical values below are transcribed from the supplied PDF for Type 455 mining cable. The tables are retained by voltage, screen option or construction section as presented in the source. Source ordering codes are included where present in the extracted table; blank source cells are not assigned new values.
Use the relevant area, conductor dimensions, insulation or covering thickness, nominal diameter and mass together. The source does not create a universal current-capacity, bend-radius, pulling-load or travel-speed value for this product.
TYPE 455.3 - 3.3 kV - ELECTRICAL DATA
| Partie | Area mm2 | Nom. dia. mm | Insul. thick. mm | AC res. oh/km | React. oh/km | Volt drop mV/A.m | Cap. uF/km |
|---|---|---|---|---|---|---|---|
| 25-455-3 | 25 | 7.3 | 2.2 | 0.951 | 0.112 | 1.66 | 0.404 |
| 35-455-3 | 35 | 8.9 | 2.2 | 0.698 | 0.105 | 1.22 | 0.462 |
| 50-455-3 | 50 | 10.2 | 2.4 | 0.523 | 0.103 | 0.923 | 0.473 |
| 70-455-3 | 70 | 12.7 | 2.4 | 0.346 | 0.0964 | 0.622 | 0.555 |
| 95-455-3 | 95 | 13.8 | 2.4 | 0.271 | 0.0941 | 0.497 | 0.593 |
| 120-455-3 | 120 | 15.7 | 2.4 | 0.210 | 0.0915 | 0.397 | 0.633 |
| 150-455-3 | 150 | 17.6 | 2.4 | 0.166 | 0.0884 | 0.326 | 0.719 |
TYPE 455.3 - 3.3 kV - EARTH, PILOT AND MASS
| Partie | Earth and pilot area each mm2 | Sheath thick. mm | Nom. dia. mm | Approx mass kg/100m |
|---|---|---|---|---|
| 25-455-3 | 8 | 4.5 | 42.2 | 300 |
| 35-455-3 | 8 | 4.8 | 46.2 | 360 |
| 50-455-3 | 12 | 5.2 | 50.7 | 455 |
| 70-455-3 | 18 | 5.7 | 56.9 | 585 |
| 95-455-3 | 25 | 6.1 | 60.2 | 700 |
| 120-455-3 | 31 | 6.4 | 65.3 | 850 |
| 150-455-3 | 39.5 | 6.5 | 69.1 | 1010 |
TYPE 455.6 - 6.6 kV - ELECTRICAL DATA
| Partie | Area mm2 | Nom. dia. mm | Insul. thick. mm | AC res. oh/km | React. oh/km | Volt drop mV/A.m | Cap. uF/km |
|---|---|---|---|---|---|---|---|
| 25-455-6 | 25 | 7.3 | 3.0 | 0.951 | 0.119 | 1.66 | 0.316 |
| 35-455-6 | 35 | 8.9 | 3.0 | 0.698 | 0.112 | 1.22 | 0.359 |
| 50-455-6 | 50 | 10.2 | 3.0 | 0.523 | 0.107 | 0.925 | 0.394 |
| 70-455-6 | 70 | 12.7 | 3.0 | 0.346 | 0.100 | 0.624 | 0.459 |
| 95-455-6 | 95 | 13.8 | 3.0 | 0.271 | 0.0978 | 0.499 | 0.490 |
| 120-455-6 | 120 | 15.7 | 3.0 | 0.210 | 0.0944 | 0.399 | 0.540 |
| 150-455-6 | 150 | 17.6 | 3.0 | 0.166 | 0.0916 | 0.328 | 0.591 |
TYPE 455.6 - 6.6 kV - EARTH, PILOT AND MASS
| Partie | Earth and pilot area each mm2 | Sheath thick. mm | Nom. dia. mm | Approx mass kg/100m |
|---|---|---|---|---|
| 25-455-6 | 8 | 5.0 | 46.8 | 345 |
| 35-455-6 | 8 | 5.3 | 50.9 | 415 |
| 50-455-6 | 12 | 5.6 | 54.2 | 500 |
| 70-455-6 | 18 | 6.0 | 60.2 | 635 |
| 95-455-6 | 25 | 6.3 | 63.3 | 745 |
| 120-455-6 | 31 | 6.5 | 67.7 | 890 |
| 150-455-6 | 39.5 | 6.6 | 72.0 | 1055 |
TYPE 455.11 - 11 kV - ELECTRICAL DATA
| Partie | Area mm2 | Nom. dia. mm | Insul. thick. mm | AC res. oh/km | React. oh/km | Volt drop mV/A.m | Cap. uF/km |
|---|---|---|---|---|---|---|---|
| 25-455-11 | 25 | 7.3 | 5.0 | 0.951 | 0.132 | 1.66 | 0.223 |
| 35-455-11 | 35 | 8.9 | 5.0 | 0.698 | 0.124 | 1.23 | 0.251 |
| 50-455-11 | 50 | 10.2 | 5.0 | 0.523 | 0.119 | 0.929 | 0.273 |
| 70-455-11 | 70 | 12.7 | 5.0 | 0.346 | 0.111 | 0.629 | 0.314 |
| 95-455-11 | 95 | 13.8 | 5.0 | 0.271 | 0.108 | 0.505 | 0.334 |
| 120-455-11 | 120 | 15.7 | 5.0 | 0.210 | 0.104 | 0.406 | 0.365 |
| 150-455-11 | 150 | 17.6 | 5.0 | 0.166 | 0.100 | 0.336 | 0.397 |
TYPE 455.11 - 11 kV - EARTH, PILOT AND MASS
| Partie | Earth and pilot area each mm2 | Sheath thick. mm | Nom. dia. mm | Approx mass kg/100m |
|---|---|---|---|---|
| 25-455-11 | 8 | 6.1 | 57.6 | 480 |
| 35-455-11 | 8 | 6.3 | 61.5 | 550 |
| 50-455-11 | 12 | 6.4 | 64.4 | 640 |
| 70-455-11 | 18 | 6.5 | 69.8 | 775 |
| 95-455-11 | 25 | 6.7 | 72.7 | 890 |
| 120-455-11 | 31 | 6.8 | 77.0 | 1040 |
| 150-455-11 | 39.5 | 6.9 | 81.3 | 1215 |
Paramètre
| Type de câble | Class 1 semiconductive screened reeling and trailing cable |
|---|---|
| Voltage range | 3.3/3.3 kV to 11/11 kV |
| Installation | In free air for mobile equipment |
| Typical service | Slow reeling and trailing applications for open-cut mining equipment |
| Mechanical protection | Extra heavy duty sheath with polyaramid braid reinforcement |
| Performance | Excellent immersion performance, very good flexibility and C1 flame performance |
7 technical tables were transcribed from the supplied datasheet; confirm final selection against the original PDF and project cable schedule.
Type 455 source-listed limits
Type 455 is recorded in the supplied datasheet as a Class 1 semiconductive screened cable to AS/NZS 2802. The voltage family is narrower than Type 450/451 and is shown here explicitly.
| Paramètre | Valeur indiquée dans la source |
|---|---|
| Norme du produit | AS/NZS 2802 |
| Voltage range | 3.3/3.3 kV to 11/11 kV |
| température de fonctionnement continue maximale | +90 °C |
| Minimum installation temperature | −25 °C |
| Installation | Free air for mobile equipment; reeling/trailing |
| Oil / water performance | Excellent immersion performance and very good flexibility |
| Comportement au feu | C1 |
Quote the exact Type 455 voltage designation and state whether the application is reeling, trailing or a materials-handling route.
Options de câbles associées
Comparez ces options de câbles en fonction de la combinaison de services, du mouvement, de la charge, de la tension et des exigences de transmission.
Câble souterrain pour mine de charbon de type 240, 1,1 kV à 11 kV
Une option de câble similaire pour une application ou un profil de service différent.
Voir le produitCâble minier type 241.1 1,1 kV | Gamme type 241
Une option de câble similaire pour une application ou un profil de service différent.
Voir le produitCâble d'alimentation blindé pour l'industrie minière TYPE260
Une option de câble similaire pour une application ou un profil de service différent.
Voir le produitDemandez une recommandation et un devis pour un câble.
Veuillez nous indiquer les services requis, la longueur du câble, les contraintes mécaniques, l'environnement, le type de terminaison et la quantité. Notre équipe examinera votre demande avant de vous établir un devis.
- Veuillez inclure le nom du produit ou son SKU, ainsi que la longueur et la quantité de câble requises.
- Joignez une fiche technique, un dessin ou une fiche de spécifications si disponible.