Obtenir un devis
CÂBLES MINIERS ET DE TUNNELAGE Modèle / construction

Type FS4 BS 6708 640/1100 V Flat Catenary Mining Cable

Type FS4 mining cable for overhead catenary systems and similar applications, with the source-defined 640/1100 V rating and 3 kV test reference.

  • Model: Type FS4
  • Conductor and insulation: flexible tinned copper with the insulation and core construction listed for this model in the supplied PDF
  • Screen, pilot, earth and armour arrangement preserved from the source datasheet
  • Heavy-duty chloroprene or PCP outer protection as listed for this model
  • Original Type datasheet available as the product download

Send the equipment, voltage, conductor area, route, quantity and document requirements for an RFQ.

Informations sur le produit
Marque
Modèle / construction
Présentation du produit

Type FS4 for overhead catenary systems and similar applications

Type FS4 mining cable is specified in the supplied BS 6708 datasheet for overhead catenary systems and similar applications. This page keeps the source-listed voltage, test reference, core functions and dimensional tables together so a procurement engineer can compare the requested model against the cable marking and the equipment connection. The editorial focus is the flat-cable geometry and overhead routing problem, not a generic promise of performance.

The supplied construction uses individually screened phase and pilot cores laid parallel in a flat configuration without contacting each other, with EPR insulation and a heavy-duty chloroprene outer sheath. That arrangement matters because FS4 is a flat cable for overhead catenary-type service, not a round coal-cutter cable. The family should therefore be selected by model, core function and installation route as well as by voltage. The gamme de câbles pour l'exploitation minière et le creusement de tunnels provides the wider TEBAOFLEX product context.

  • Choisir par : confirm the catenary support, flat orientation, spacing and termination geometry; do not replace it with a round trailing cable by voltage match alone.
  • Confirmez avant de commander : existing sheath marking, conductor area, cable length, route, support or handling system, terminations and the required inspection documents.
  • Do not infer: values not listed in the supplied PDF, such as a different current basis, water/oil/UV performance, certification scope or mechanical interchangeability.

Le BS 6708 mining cable replacement guide is useful when a flat catenary route must be kept distinct from round trailing and coal-cutter constructions.

For a technical quotation, send the equipment nameplate or existing cable marking, voltage and size requirement, installation conditions, quantity, destination and any project-specific test or documentation requirement.

Construction

Type FS4 construction

The cross-section below is the supplied construction drawing for Type FS4. The ordering decision is driven by FS4 is a flat cable for overhead catenary-type service, not a round coal-cutter cable.

Type FS4 cable cross-section showing the supplied power, pilot, earth, screen and protection arrangement
Supplied Type FS4 cross-section; the exact core and armour arrangement must be checked against the product datasheet.

Source-listed construction

Élément de constructionValeur indiquée dans la source
ConducteurElectrolytic stranded tinned copper wire, IEC 60228 Class 5
IsolationIsolation EPR
ÉcranTinned copper braided screen over phase and pilot cores
Lay-upAll cores laid parallel in flat configuration without contacting each other
GaineHeavy-duty chloroprene outer sheath

Do not use the drawing as a substitute for the dimensional tables. Confirm the cable end preparation, screen and earth termination, armour bonding and machine interface with the equipment documentation before installation.

Applications

Type FS4 applications

The supplied datasheet identifies this cable for overhead catenary systems and similar applications. Google result patterns for the BS 6708 family also separate cables by equipment duty, voltage class, core function and whether the route is armoured, screened, flat or auxiliary. That is why this page keeps the Type FS4 construction separate from nearby Type numbers.

  • Primary duty: overhead catenary systems and similar applications.
  • Model boundary: FS4 is a flat cable for overhead catenary-type service, not a round coal-cutter cable.
  • Project check: match the cable marking, core map, voltage, termination, route geometry and handling method to the machine drawing.
  • Environmental review: confirm the actual mine/quarry conditions and any authority, inspection or documentation requirements; do not infer a certification or material-resistance claim from the model number.

If the route is a round armoured trailing arrangement rather than a flat catenary layout, review the Type 201/211 armoured trailing cable as a different construction path.

The cable should be released only after the equipment route, required length, conductor area, core functions and connection details are agreed. If the intended duty is different from the source-listed application, request an engineering review through the quotation process.

Caractéristiques

Type FS4 specifications

The summary below identifies the supplied model family. The source-transcribed tables that follow retain the PDF's dimensional, electrical and construction values, including available sizes, resistance, current, diameter, mass, bending or pulling data when the PDF provides them.

Selection itemSource-linked value
ModèleType FS4
Tension nominale640/1100 V
Tension d'essai3 kV
Applicationoverhead catenary systems and similar applications
Norme du produitBS 6708

Complete source-transcribed technical tables

Source PDF: BS6708_TYPE_FS4_640_1100V_FLAT_CABLE_datasheet.pdf; 2 pages; 6 extracted tables. Values are not recalculated or replaced by third-party values.

Source table 1, PDF page 1
ParamètreValeur
ConducteurElectrolytic stranded tinned copper wire, IEC 60228 Class 5
IsolationIsolation EPR
SéparateurColoured textile tape for core identification
ÉcranTinned copper braided screen over phase and pilot cores
Lay-upAll cores are laid parallel in flat configuration without contacting each other
gaine extérieureHeavy duty chloroprene outer sheath
Source table 2, PDF page 1
ParamètreValeur
StandardBS 6708
Tension nominale640/1100 V
Tension d'essai3 kV
Type de câbleFlat configuration with individually screened phase and pilot cores
Source table 1, PDF page 2
CORE DIMENSIONS
Nominal cross sectionConducteursStranding mmCond. dia. mmInsul. thick. mm
4x2.54x2.550/0.252.101.0
4x44x450/0.302.701.0
Source table 2, PDF page 2
CABLE DETAILS
Nominal cross sectionOuter sheath thick. mmMin. overall dimensions mmMax. overall dimensions mmMin. bend radius mmApprox. weight kg/kmCopper weight kg/km
4x2.53.818.1 x 12.420.1 x 14.4100450160
4x43.832.2 x 13.334.1 x 15.3120550230
Source table 3, PDF page 2
CURRENT RATINGS
Nominal cross sectionContinuous current rating at 25 deg C
4x2.528
4x437
Source table 4, PDF page 2
ELECTRICAL DETAILS
Nominal cross sectionConductors DC res. at 20 deg C ohm/kmEach screen DC res. at 20 deg C ohm/km
4x2.57.827.40
4x44.858.48

Use the table values with the equipment drawing and approved termination plan. If the requested conductor area, current basis, mechanical limit or environmental condition is not listed in the supplied PDF, treat it as a quotation-stage confirmation item.

Normes

Type FS4 standards and references

ObjetSource-linked reference
Norme du produitBS 6708
Tension nominale640/1100 V
Tension d'essai3 kV
Source applicationoverhead catenary systems and similar applications

The product page preserves the BS 6708 reference appearing in the supplied PDF. The BSI record currently identifies BS 6708:1998 as withdrawn on 22 May 2026; this status note is a standards-reference update, not a claim that the product is currently certified or approved. See the official BSI BS 6708 scope record for the published status.

For an RFQ, state the required standard documents, inspection scope, test report, cable marking, destination rules and any replacement-equivalence requirement. The model number alone does not establish legal installation compliance.

Comparer par fonction

Options de câbles associées

Comparez ces options de câbles en fonction de la combinaison de services, du mouvement, de la charge, de la tension et des exigences de transmission.

devis basé sur l'ingénierie

Demandez une recommandation et un devis pour un câble.

Veuillez nous indiquer les services requis, la longueur du câble, les contraintes mécaniques, l'environnement, le type de terminaison et la quantité. Notre équipe examinera votre demande avant de vous établir un devis.

  • Veuillez inclure le nom du produit ou son SKU, ainsi que la longueur et la quantité de câble requises.
  • Joignez une fiche technique, un dessin ou une fiche de spécifications si disponible.

    Facultatif : joindre une spécification de câble, un dessin, une fiche technique ou une image du produit (PDF, DOC, DOCX, XLS, XLSX, CSV, JPG ou PNG ; maximum 10 Mo).

    En soumettant ce formulaire, vous acceptez que TEBAOFLEX utilise vos coordonnées et les fichiers fournis pour examiner votre demande et y répondre. Les fichiers servent à l'établissement du devis et aux échanges techniques relatifs à votre demande. Consultez notre politique de confidentialité. politique de confidentialité pour obtenir des informations à jour sur le traitement et la conservation des données.

    * Champs obligatoires. Veuillez inclure les détails du câble principal ou de l'application pour examen.