UL 3580 Silicone Motor Lead Wire, 150°C 1000V
UL 3580 is a UL-certified silicone motor lead wire rated 150°C and 1000 V AC. It is intended for motor leads and internal appliance or electronic equipment wiring where the lead is protected from mechanical abuse.
- Napięcie: 1000 V AC
- Temperatura: 150°C
- Izolacja / powłoka: extruded silicone rubber
- Dobór przekroju: 26 AWG–500 kcmil style range; table: 26–6 AWG
- Certyfikacja: AWM z certyfikatem UL; UL 758
UL 3580 wire selection
UL 3580 is a UL-certified silicone motor lead wire rated 150°C and 1000 V AC. It is intended for motor leads and internal appliance or electronic equipment wiring where the lead is protected from mechanical abuse.
The detailed size table covers 26–6 AWG. Nominal silicone thickness is 1.20 mm in the 26–10 AWG rows and 1.58 mm in the 8–6 AWG rows. Conductor stranding and finished diameter are listed with each model-size combination to help check motor terminal entries, connection boxes and protective sleeves. A separate insulation schedule explains the larger conductor groups within the style range.
For a motor connection, allow space for the finished wire rather than selecting the entry around the bare conductor size. The listed construction uses a bend radius of 10 times its finished diameter. Check the temperature near the winding exit and at the connection hardware, because the 150°C wire rating must be compatible with the rest of the assembly.
Tabele modeli i rozmiarów znajdują się w zakładce Specyfikacja. Przejrzyj kategorię gamę kabli wysokotemperaturowych for related constructions. Compare UL 3644 for a different 1 kV wall schedule and the silikonowe przewody przyłączeniowe for lower-voltage options.
Budowa
UL 3580 uses the following conductor and insulation system. The diagram illustrates the layer sequence; select the conductor construction and covering shown in the required size specification.

| Element | Szczegóły budowy |
|---|---|
| Żyła przewodząca | Solid or stranded copper; dimensioned examples are stranded |
| Izolacja | Wytłaczana guma silikonowa |
Zastosowania
UL 3580 is used as motor lead wire and for internal appliance or electronic equipment wiring. Route and support the lead to prevent rubbing or mechanical damage at the winding exit and terminal enclosure.

UL 3580 replacement selection
Przy zapytaniu o zamiennik podaj oznaczenie dotychczasowego przewodu i rysunek połączeń urządzenia, aby można było dopasować żyłę, izolację i układ zacisków.
Dane techniczne
| Parametr | Specyfikacja |
|---|---|
| Styl UL | UL 3580 |
| Napięcie znamionowe | 1000 V AC |
| Klasa temperaturowa | 150°C |
| Izolacja / warstwa ochronna | extruded silicone rubber |
| Zakres rozmiarów żył | 26 AWG–500 kcmil style range; table: 26–6 AWG |
| Bending radius for listed construction | 10 × finished OD |
Nominal dimensions follow the listed conductor constructions. Confirm the agreed finished-diameter drawing for tight-clearance assemblies.
| Model i rozmiar żyły | Liczba drutów żyły (szt./mm) | Nominal silicone wall (mm) | Nominalna średnica zewnętrzna / tolerancja (mm) |
|---|---|---|---|
| UL 3580 6 AWG | 259/0.254 | 1.58 | 7.89 ±0.10 |
| UL 3580 8 AWG | 161/0.254 | 1.58 | 6.88 ±0.10 |
| UL 3580 10 AWG | 105/0.254 | 1.20 | 5.41 ±0.10 |
| UL 3580 12 AWG | 65/0.254 | 1.20 | 4.77 ±0.10 |
| UL 3580 14 AWG | 41/0.254 | 1.20 | 4.28 ±0.10 |
| UL 3580 16 AWG | 26/0.254 | 1.20 | 3.90 ±0.10 |
| UL 3580 18 AWG | 34/0.18 | 1.20 | 3.62 ±0.10 |
| UL 3580 20 AWG | 21/0.18 | 1.20 | 3.36 ±0.10 |
| UL 3580 22 AWG | 17/0.16 | 1.20 | 3.17 ±0.10 |
| UL 3580 24 AWG | 11/0.16 | 1.20 | 3.02 ±0.10 |
| UL 3580 26 AWG | 7/0.16 | 1.20 | 2.89 ±0.10 |
Style construction thicknesses are shown in mils; 1 mil = 0.0254 mm. Nominal finished dimensions are listed separately.
| Model and conductor group | Minimum average silicone wall (mils) | Minimum point wall (mils) |
|---|---|---|
| UL 3580 26–9 AWG | 45 | 40 |
| UL 3580 8–2 AWG | 60 | 54 |
| UL 3580 1–4/0 AWG | 80 | 72 |
| UL 3580 250–500 kcmil | 95 | 86 |
Dobór wymaganej konstrukcji
Specify UL 3580 with AWG or kcmil, stranding, required OD and connection temperature. For a size outside the dimension table, use the insulation schedule as a starting point and request the corresponding drawing.
Normy
TEBAOFLEX UL 3580 wire is UL-certified appliance wiring material.
| Pozycja | Wymaganie lub odniesienie |
|---|---|
| Certyfikacja | AWM z certyfikatem UL |
| Oznaczenie stylu | UL 3580 |
| Norma konstrukcyjna | UL 758 — Materiały do okablowania urządzeń |
| Klasyfikacja palności stylu | Pozioma próba płomieniowa |
W specyfikacji zakupowej podaj styl UL, rozmiar żyły oraz klasę napięciową i temperaturową. Do zapytania dołącz wymaganą identyfikację produktu i dokumenty certyfikacyjne.
Poproś o dobór kabla i wycenę
Prześlij wymagane funkcje, długość kabla, warunki pracy mechanicznej, środowisko, zakończenia i ilość. Nasz zespół przeanalizuje zastosowanie przed przygotowaniem wyceny.
- Podaj nazwę produktu lub SKU oraz wymaganą długość kabla i ilość.
- Jeśli są dostępne, dołącz specyfikację, rysunek lub kartę katalogową.