Zapytaj o ofertę
Kable odporne na wysoką temperaturę

UL 3580 Silicone Motor Lead Wire, 150°C 1000V

UL 3580 is a UL-certified silicone motor lead wire rated 150°C and 1000 V AC. It is intended for motor leads and internal appliance or electronic equipment wiring where the lead is protected from mechanical abuse.

  • Napięcie: 1000 V AC
  • Temperatura: 150°C
  • Izolacja / powłoka: extruded silicone rubber
  • Dobór przekroju: 26 AWG–500 kcmil style range; table: 26–6 AWG
  • Certyfikacja: AWM z certyfikatem UL; UL 758
Informacje o produkcie
Przegląd produktu

UL 3580 wire selection

UL 3580 is a UL-certified silicone motor lead wire rated 150°C and 1000 V AC. It is intended for motor leads and internal appliance or electronic equipment wiring where the lead is protected from mechanical abuse.

The detailed size table covers 26–6 AWG. Nominal silicone thickness is 1.20 mm in the 26–10 AWG rows and 1.58 mm in the 8–6 AWG rows. Conductor stranding and finished diameter are listed with each model-size combination to help check motor terminal entries, connection boxes and protective sleeves. A separate insulation schedule explains the larger conductor groups within the style range.

For a motor connection, allow space for the finished wire rather than selecting the entry around the bare conductor size. The listed construction uses a bend radius of 10 times its finished diameter. Check the temperature near the winding exit and at the connection hardware, because the 150°C wire rating must be compatible with the rest of the assembly.

Tabele modeli i rozmiarów znajdują się w zakładce Specyfikacja. Przejrzyj kategorię gamę kabli wysokotemperaturowych for related constructions. Compare UL 3644 for a different 1 kV wall schedule and the silikonowe przewody przyłączeniowe for lower-voltage options.

Budowa

Budowa

UL 3580 uses the following conductor and insulation system. The diagram illustrates the layer sequence; select the conductor construction and covering shown in the required size specification.

Illustrative UL 3580 single-core conductor and insulation construction cutaway
Illustrative UL 3580 construction; layer dimensions are not to scale.
UL 3580 construction layers
ElementSzczegóły budowy
Żyła przewodzącaSolid or stranded copper; dimensioned examples are stranded
IzolacjaWytłaczana guma silikonowa
Zastosowania

Zastosowania

UL 3580 is used as motor lead wire and for internal appliance or electronic equipment wiring. Route and support the lead to prevent rubbing or mechanical damage at the winding exit and terminal enclosure.

Illustrative UL 3580 insulated lead routed inside industrial equipment
Illustrative UL 3580 equipment application; shown as an installation concept.

UL 3580 replacement selection

Przy zapytaniu o zamiennik podaj oznaczenie dotychczasowego przewodu i rysunek połączeń urządzenia, aby można było dopasować żyłę, izolację i układ zacisków.

Dane techniczne

Dane techniczne

UL 3580 technical data
ParametrSpecyfikacja
Styl ULUL 3580
Napięcie znamionowe1000 V AC
Klasa temperaturowa150°C
Izolacja / warstwa ochronnaextruded silicone rubber
Zakres rozmiarów żył26 AWG–500 kcmil style range; table: 26–6 AWG
Bending radius for listed construction10 × finished OD

Nominal dimensions follow the listed conductor constructions. Confirm the agreed finished-diameter drawing for tight-clearance assemblies.

UL 3580 size and dimension table
Model i rozmiar żyłyLiczba drutów żyły (szt./mm)Nominal silicone wall (mm)Nominalna średnica zewnętrzna / tolerancja (mm)
UL 3580 6 AWG259/0.2541.587.89 ±0.10
UL 3580 8 AWG161/0.2541.586.88 ±0.10
UL 3580 10 AWG105/0.2541.205.41 ±0.10
UL 3580 12 AWG65/0.2541.204.77 ±0.10
UL 3580 14 AWG41/0.2541.204.28 ±0.10
UL 3580 16 AWG26/0.2541.203.90 ±0.10
UL 3580 18 AWG34/0.181.203.62 ±0.10
UL 3580 20 AWG21/0.181.203.36 ±0.10
UL 3580 22 AWG17/0.161.203.17 ±0.10
UL 3580 24 AWG11/0.161.203.02 ±0.10
UL 3580 26 AWG7/0.161.202.89 ±0.10

Style construction thicknesses are shown in mils; 1 mil = 0.0254 mm. Nominal finished dimensions are listed separately.

UL 3580 insulation thickness by conductor size
Model and conductor groupMinimum average silicone wall (mils)Minimum point wall (mils)
UL 3580 26–9 AWG4540
UL 3580 8–2 AWG6054
UL 3580 1–4/0 AWG8072
UL 3580 250–500 kcmil9586

Dobór wymaganej konstrukcji

Specify UL 3580 with AWG or kcmil, stranding, required OD and connection temperature. For a size outside the dimension table, use the insulation schedule as a starting point and request the corresponding drawing.

Normy

Normy

TEBAOFLEX UL 3580 wire is UL-certified appliance wiring material.

UL 3580 certification and standards
PozycjaWymaganie lub odniesienie
CertyfikacjaAWM z certyfikatem UL
Oznaczenie styluUL 3580
Norma konstrukcyjnaUL 758 — Materiały do okablowania urządzeń
Klasyfikacja palności styluPozioma próba płomieniowa

W specyfikacji zakupowej podaj styl UL, rozmiar żyły oraz klasę napięciową i temperaturową. Do zapytania dołącz wymaganą identyfikację produktu i dokumenty certyfikacyjne.

Wycena oparta na analizie technicznej

Poproś o dobór kabla i wycenę

Prześlij wymagane funkcje, długość kabla, warunki pracy mechanicznej, środowisko, zakończenia i ilość. Nasz zespół przeanalizuje zastosowanie przed przygotowaniem wyceny.

  • Podaj nazwę produktu lub SKU oraz wymaganą długość kabla i ilość.
  • Jeśli są dostępne, dołącz specyfikację, rysunek lub kartę katalogową.

    Wysyłając ten formularz, zgadzasz się, aby TEBAOFLEX wykorzystywał podane dane kontaktowe i pliki do rozpatrzenia Twojego zapytania oraz udzielenia odpowiedzi. Pliki służą do przygotowania oferty i komunikacji technicznej związanej z zapytaniem. Zapoznaj się z dokumentem: Polityka prywatności Zawiera on aktualne informacje dotyczące przetwarzania i przechowywania danych.

    * Pola wymagane. Podaj najważniejsze informacje o kablu lub zastosowaniu do analizy.