  • Model: Type 43
  • Conductor and insulation: flexible tinned copper with the insulation and core construction listed for this model in the supplied PDF
  • Screen, pilot, earth and armour arrangement preserved from the source datasheet
  • Heavy-duty chloroprene or PCP outer protection as listed for this model
  • Original Type datasheet available as the product download

Send the equipment, voltage, conductor area, route, quantity and document requirements for an RFQ.

Product information
Brand
TEBAOFLEX
Product overview

Type 43 for hand-held drilling machines in deep mines and on the surface

Type 43 mining cable is specified in the supplied BS 6708 datasheet for hand-held drilling machines in deep mines and on the surface. This page keeps the source-listed voltage, test reference, core functions and dimensional tables together so a procurement engineer can compare the requested model against the cable marking and the equipment connection. The editorial focus is the conducting-elastomer screen route for low-voltage drill service, not a generic promise of performance.

The supplied construction uses three phase cores, one pilot and one earth core laid without contact around a semiconducting cradle, with a conducting elastomeric compound and heavy-duty chloroprene sheath. That arrangement matters because Type 43 uses the non-metallic conducting screen construction; Type 44 uses a tinned copper/nylon braided phase screen. The family should therefore be selected by model, core function and installation route as well as by voltage. The mining and tunnelling cable range provides the wider TEBAOFLEX product context.

  • Choose by: confirm the drilling-machine voltage, semiconductive cradle arrangement and non-metallic screen requirement before comparing with Type 44.
  • Confirm before ordering: existing sheath marking, conductor area, cable length, route, support or handling system, terminations and the required inspection documents.
  • Do not infer: values not listed in the supplied PDF, such as a different current basis, water/oil/UV performance, certification scope or mechanical interchangeability.

When a hand-held drill cable is being replaced, the BS 6708 mining cable replacement guide helps keep the low-voltage drill family and its screen construction distinctions visible.

For a technical quotation, send the equipment nameplate or existing cable marking, voltage and size requirement, installation conditions, quantity, destination and any project-specific test or documentation requirement.

Construction

Type 43 construction

The cross-section below is the supplied construction drawing for Type 43. The ordering decision is driven by Type 43 uses the non-metallic conducting screen construction; Type 44 uses a tinned copper/nylon braided phase screen.

Type 43 cable cross-section showing the supplied power, pilot, earth, screen and protection arrangement
Supplied Type 43 cross-section; the exact core and armour arrangement must be checked against the product datasheet.

Source-listed construction

Construction elementSource-listed value
ConductorElectrolytic stranded tinned copper wire, IEC 60228 Class 5
InsulationEPR insulation
Lay-upAll cores laid without contact around a semiconducting cradle
BeddingConducting elastomeric compound
SheathHeavy-duty chloroprene outer sheath
Core arrangementThree phase cores, one pilot and one earth core around the semiconducting cradle

Do not use the drawing as a substitute for the dimensional tables. Confirm the cable end preparation, screen and earth termination, armour bonding and machine interface with the equipment documentation before installation.

Applications

Type 43 applications

Type 43 mining cable application with hand-held drilling equipment underground
Media-library application scene showing hand-held drilling equipment underground; used for application context, not as a model-specific construction proof.

The supplied datasheet identifies this cable for hand-held drilling machines in deep mines and on the surface. Google result patterns for the BS 6708 family also separate cables by equipment duty, voltage class, core function and whether the route is armoured, screened, flat or auxiliary. That is why this page keeps the Type 43 construction separate from nearby Type numbers.

  • Primary duty: hand-held drilling machines in deep mines and on the surface.
  • Model boundary: Type 43 uses the non-metallic conducting screen construction; Type 44 uses a tinned copper/nylon braided phase screen.
  • Project check: match the cable marking, core map, voltage, termination, route geometry and handling method to the machine drawing.
  • Environmental review: confirm the actual mine/quarry conditions and any authority, inspection or documentation requirements; do not infer a certification or material-resistance claim from the model number.

The metallic-screened Type 44 drill cable is the closest model comparison when the project requires a different screen construction; verify the drill maker's cable interface before ordering.

The cable should be released only after the equipment route, required length, conductor area, core functions and connection details are agreed. If the intended duty is different from the source-listed application, request an engineering review through the quotation process.

Specifications

Type 43 specifications

The summary below identifies the supplied model family. The source-transcribed tables that follow retain the PDF's dimensional, electrical and construction values, including available sizes, resistance, current, diameter, mass, bending or pulling data when the PDF provides them.

Selection itemSource-linked value
ModelType 43
Rated voltage125/72 V
Test voltage1.5 kV
Applicationhand-held drilling machines in deep mines and on the surface
Product standardBS 6708

Complete source-transcribed technical tables

Source PDF: BS6708_TYPE_43_125_72V_HANDHELD_DRILLING_MACHINE_CABLE_datasheet.pdf; 3 pages; 6 extracted tables. Values are not recalculated or replaced by third-party values.

Source table 1, PDF page 1
ParameterValue
ConductorElectrolytic, stranded, tinned copper wire, IEC 60228 Class 5
InsulationEPR
Lay-upAll cores are laid up without contacting each other around a semiconducting cradle
BeddingConducting elastomeric compound
Outer sheathHeavy duty chloroprene outer sheath
Source table 2, PDF page 1
ParameterValue
StandardBS 6708
Rated voltage125/72 V
Test voltage1.5 kV
Cable typeThree phase cores, one pilot core and one earth core laid up around a semiconducting cradle and screened by semiconducting filler
Source table 1, PDF page 2
CORE DIMENSIONS
Nominal cross sectionConductorsStranding mmConductor diameter mmInsulation thickness mm
5x65x684/0.303.301.00
Source table 2, PDF page 2
CABLE DETAILS
Nominal cross sectionConducting inner sheath thickness mmOuter sheath thickness mmMin. OD mmMax. OD mmMin. bend radius mmApprox. weight kg/kmCopper weight kg/km
5x61.52.524.826.82681020150
Source table 1, PDF page 3
CURRENT RATINGS
Nominal cross sectionContinuous current rating at 25 deg C
5x646
Source table 2, PDF page 3
ELECTRICAL DETAILS
Nominal F cross sectionConductors E Max. DC res. at 20 deg C ohm/km
5x63.48

Use the table values with the equipment drawing and approved termination plan. If the requested conductor area, current basis, mechanical limit or environmental condition is not listed in the supplied PDF, treat it as a quotation-stage confirmation item.

Standards

Type 43 standards and references

SubjectSource-linked reference
Product standardBS 6708
Rated voltage125/72 V
Test voltage1.5 kV
Source applicationhand-held drilling machines in deep mines and on the surface

The product page preserves the BS 6708 reference appearing in the supplied PDF. The BSI record currently identifies BS 6708:1998 as withdrawn on 22 May 2026; this status note is a standards-reference update, not a claim that the product is currently certified or approved. See the official BSI BS 6708 scope record for the published status.

For an RFQ, state the required standard documents, inspection scope, test report, cable marking, destination rules and any replacement-equivalence requirement. The model number alone does not establish legal installation compliance.

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    Optional: attach a cable specification, drawing, data sheet or product image (PDF, DOC, DOCX, XLS, XLSX, CSV, JPG or PNG; maximum 10 MB).

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.