BS 6708 Type 62 / 63 / 64 Armoured Cable 640/1100 V
BS 6708 Type 62, 63 and 64 cables are 640/1100 V individually screened, pliable-wire-armoured cables for mine control and lighting circuits.
- Type 62: 2 × 4 mm²; Type 63: 3 × 4 mm²; Type 64: 4 × 4 mm².
- IEC 60228 Class 5 tinned-copper conductors.
- EPR insulation with tinned-copper/nylon core screens.
- Galvanized steel pliable armour.
- Heavy-duty chloroprene outer sheath.
- Test voltage: 2.5 kV.
BS 6708 Type 62, 63 and 64 armoured mining cables
BS 6708 Type 62, 63 and 64 cables are 640/1100 V flexible cables with individually screened cores, galvanized steel pliable-wire armour and a heavy-duty chloroprene outer sheath. The range comprises two, three and four 4 mm² cores respectively.
These constructions serve mine remote-control and coalface-lighting circuits. The individual composite screens surround each insulated core, while the armour protects the assembled cable beneath the outer sheath. Keeping the three types together makes it easier to compare core count, finished diameter, mass and handling dimensions for an existing installation.
- Type 62: two 4 mm² cores for the corresponding two-core circuit.
- Type 63: three 4 mm² cores in the BS 6708 construction.
- Type 64: four 4 mm² cores with the largest diameter in this group.
- Route planning: use the type-specific bending radius, pulling tension and diameter range to assess supports, glands and clearances.
The Specifications section provides the mechanical and electrical tables, including the temperature and circuit basis for current and voltage-drop data. Browse the mining and tunnelling cable range for adjacent constructions, or use the BS 6708 cable replacement guide to identify the required cable type.
Individually screened cores and pliable-wire armour
Each EPR-insulated core has a tinned-copper/nylon composite screen. The cores are laid in contact inside a rubber bedding, with galvanized steel pliable armour between the inner and outer sheaths.

| Element | Construction |
|---|---|
| Conductor | Stranded tinned copper, IEC 60228 Class 5 |
| Insulation | EPR |
| Individual core screen | Tinned-copper/nylon braid |
| Core arrangement | Type 62: two cores; Type 63: three cores; Type 64: four cores |
| Bedding | Rubber-based compound |
| Armour | Galvanized steel pliable-wire armour |
| Outer sheath | Heavy-duty chloroprene |
Mine remote-control and lighting circuits
BS Type 62, Type 63 and Type 64 cables are used for remote-control circuits and coalface lighting in mines. The available core counts support the corresponding equipment and lighting circuit arrangements.

- Coalface lighting: screened cable connections between the lighting circuit components.
- Remote control: two-, three- or four-core circuits using the specified 4 mm² conductor size.
- Replacement installations: type-specific diameter, mass and bend-radius data support route and gland selection.
Identify Type 63 by its standard
The BS 6708 Type 63 cable here is a three-core 640/1100 V construction. The SANS Type 63 mining cable is a separate 1.9/3.3 kV construction. Use the complete standard and type designation in the equipment schedule.
BS Type 62 / 63 / 64 sizes and technical data
| Parameter | Value |
|---|---|
| Rated voltage | 640/1100 V |
| Test voltage | 2.5 kV |
| Conductor stranding | 56/0.30 mm |
| Conductor diameter | 2.60 mm |
| Diameter over insulation | 4.80 mm |
| Diameter over core screen | 6.00 mm |
| Configuration | Inner sheath diameter, min–max (mm) | Overall diameter, min–max (mm) | Minimum bend radius (mm) | Maximum pulling tension (kgf) | Approximate mass (kg/km) | Copper mass (kg/km) |
|---|---|---|---|---|---|---|
| Type 62 2 × 4 mm² | 16.2–18.2 | 23.9–26.4 | 270 | 48 | 1080 | 132 |
| Type 63 3 × 4 mm² | 17.1–19.1 | 24.8–27.3 | 280 | 72 | 1230 | 200 |
| Type 64 4 × 4 mm² | 18.7–20.7 | 26.4–29.9 | 290 | 96 | 1400 | 264 |
| Configuration | Continuous current, 25 °C ambient (A) | Max. phase DC resistance, 20 °C (Ω/km) | Max. screen DC resistance, parallel, 20 °C (Ω/km) | Max. armour DC resistance, 20 °C (Ω/km) | Reactance 50 / 60 Hz (Ω/km) | Full-load voltage drop (mV/A/m) |
|---|---|---|---|---|---|---|
| Type 62 2 × 4 mm² | 28 | 5.09 | 5.5 | 4.91 | 0.119 / 0.143 | 12.38 |
| Type 63 3 × 4 mm² | 28 | 5.09 | 3.9 | 4.63 | 0.119 / 0.143 | 10.72 |
| Type 64 4 × 4 mm² | 28 | 5.09 | 2.8 | 4.16 | 0.119 / 0.143 | 10.72 |
Continuous current ratings are stated at 25 °C ambient. DC resistance values are at 20 °C. Type 62 voltage drop is calculated for single phase; Type 63 and Type 64 values are for three phase at full load. Pulling tension is expressed in kgf. Dimensions and mass are nominal.
BS 6708 design references
BS 6708:1998 — flexible cables for mines and quarries is the legacy design reference for this cable family. BSI withdrew the 1998 edition on 22 May 2026.
- Conductor construction: IEC 60228 Class 5.
- Rated voltage: 640/1100 V.
- Test voltage: 2.5 kV.
- Type 62, 63 and 64: individually screened cores with galvanized steel pliable-wire armour.
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
Type 20 / Type 21 BS 6708 640/1100 V Armoured Mining Cable
A related cable option for a different application or duty profile.
View productType 201 / Type 211 BS 6708 640/1100 V Armoured Trailing Cable
A related cable option for a different application or duty profile.
View productType FS4 BS 6708 640/1100 V Flat Catenary Mining Cable
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.