UL 5334 & UL 5335 Mica-Glass Wire, 450°C 300/600V
UL 5334 and UL 5335 are UL-certified mica-glass wires for high-temperature internal equipment connections at 450°C. UL 5334 is the 300 V AC construction, while UL 5335 is the 600 V AC construction. Both use a stranded nickel-coated copper conductor, mica-glass insulation and a treated fiberglass braid.
- tension: UL 5334: 300 V AC; UL 5335: 600 V AC
- Température: 450°C
- Isolation / revêtement : mica-glass composite with fiberglass braid
- Sélection de la taille : UL 5334: 24–14 AWG; UL 5335: 22–8 AWG in dimension tables
- Certification : AWM certifié UL; UL 758
UL 5334 / UL 5335 wire selection
UL 5334 and UL 5335 are UL-certified mica-glass wires for high-temperature internal equipment connections at 450°C. UL 5334 is the 300 V AC construction, while UL 5335 is the 600 V AC construction. Both use a stranded nickel-coated copper conductor, mica-glass insulation and a treated fiberglass braid.
Separate size tables keep the voltage choices clear. UL 5334 dimensions cover 24–14 AWG, and UL 5335 dimensions cover 22–8 AWG. Each row includes strand count, outside diameter, approximate weight and minimum bend radius. These values let a buyer compare the two constructions at a shared AWG without assuming that the thicker voltage construction will fit the same entry or terminal arrangement.
For ovens and similar hot equipment, consider both the hot-zone temperature and the mechanical protection along the wire route. The insulation system needs a supported installation, and the conductor size still depends on the complete circuit and thermal conditions. A 450°C rating alone is not a current-carrying-capacity calculation or a basis for replacing one voltage grade with another.
Consultez l’onglet Caractéristiques pour les tableaux de modèles et de calibres. Parcourez la gamme de câbles haute température pour des constructions apparentées. Comparer MGT mica-glass wire for the existing 5107/5128 mica-tape product rather than treating the constructions as certified equivalents.
Construction
UL 5334 / UL 5335 uses the following conductor and insulation system. The diagram illustrates the layer sequence; select the conductor construction and covering shown in the required size specification.

| Composant | détail de construction |
|---|---|
| Conducteur | Stranded 27% nickel-coated copper |
| Isolation | Mica-glass composite |
| Revêtement extérieur | Fiberglass braid with high-temperature finish |
Applications
UL 5334 and UL 5335 are used for internal wiring in ovens and similar high-temperature equipment where protected from mechanical abuse. Choose the 300 V or 600 V construction before checking the required conductor size.

UL 5334 / UL 5335 replacement selection
Pour une demande de remplacement, fournissez le marquage du fil existant et le schéma de raccordement de l’équipement afin de comparer le conducteur, l’isolation et la disposition des bornes.
Caractéristiques techniques
| Paramètre | Spécification |
|---|---|
| Style UL | UL 5334 / UL 5335 |
| Tension assignée | UL 5334: 300 V AC; UL 5335: 600 V AC |
| Indice de température | 450°C |
| Isolation / revêtement | mica-glass composite with fiberglass braid |
| Plage de calibres du conducteur | UL 5334: 24–14 AWG; UL 5335: 22–8 AWG in dimension tables |
| UL 5334 rating | 450°C, 300 V AC |
| UL 5335 rating | 450°C, 600 V AC |
| Modèle et calibre du conducteur | Brins | OD (mm) | OD (in) | Poids (kg/km) | Weight (lb/1000 ft) | Rayon de courbure min. (in) |
|---|---|---|---|---|---|---|
| UL 5334 24 AWG | 7 | 1.73 | 0.068 | 6.37 | 4 | 0.54 |
| UL 5334 22 AWG | 7 | 2.06 | 0.081 | 8.83 | 6 | 0.65 |
| UL 5334 20 AWG | 10 | 2.24 | 0.088 | 11.19 | 8 | 0.70 |
| UL 5334 18 AWG | 16 | 2.44 | 0.096 | 14.51 | 10 | 0.77 |
| UL 5334 16 AWG | 26 | 2.79 | 0.110 | 20.43 | 14 | 0.88 |
| UL 5334 14 AWG | 41 | 3.20 | 0.126 | 29.33 | 20 | 1.01 |
| Modèle et calibre du conducteur | Brins | OD (mm) | OD (in) | Poids (kg/km) | Weight (lb/1000 ft) | Rayon de courbure min. (in) |
|---|---|---|---|---|---|---|
| UL 5335 22 AWG | 7 | 2.49 | 0.098 | 11.01 | 7 | 0.78 |
| UL 5335 20 AWG | 10 | 2.74 | 0.108 | 14.53 | 10 | 0.86 |
| UL 5335 18 AWG | 16 | 3.05 | 0.120 | 19.05 | 13 | 0.96 |
| UL 5335 16 AWG | 26 | 3.40 | 0.134 | 25.54 | 17 | 1.07 |
| UL 5335 14 AWG | 41 | 3.81 | 0.150 | 34.62 | 23 | 1.20 |
| UL 5335 12 AWG | 65 | 4.32 | 0.170 | 49.22 | 33 | 1.36 |
| UL 5335 10 AWG | 105 | 5.36 | 0.211 | 77.25 | 52 | 1.69 |
| UL 5335 8 AWG | 133 | 6.63 | 0.261 | 114.21 | 77 | 2.09 |
Choix de la construction spécifiée
State UL 5334 or UL 5335 explicitly with AWG, conductor construction and required voltage. Use the corresponding table for OD, weight and bend radius.
Normes
TEBAOFLEX UL 5334 / UL 5335 wire is UL-certified appliance wiring material.
| Article | Exigence ou référence |
|---|---|
| Certification | AWM certifié UL |
| Désignation du style | UL 5334 / UL 5335 |
| Norme de construction | UL 758 — Matériaux de câblage pour appareils |
| Classement au feu du style | Flamme horizontale |
Indiquez le style UL, le calibre du conducteur et les classes de tension et de température dans le cahier des charges. Joignez à la demande l’identification du produit et les documents de certification requis.
UL 5334 identifies the 300 V construction and UL 5335 identifies the 600 V construction. Keep the two styles separate on drawings and orders.
Demandez une recommandation et un devis pour un câble.
Veuillez nous indiquer les services requis, la longueur du câble, les contraintes mécaniques, l'environnement, le type de terminaison et la quantité. Notre équipe examinera votre demande avant de vous établir un devis.
- Veuillez inclure le nom du produit ou son SKU, ainsi que la longueur et la quantité de câble requises.
- Joignez une fiche technique, un dessin ou une fiche de spécifications si disponible.