NSSHKCGEOEU 0.6/1kV Coal Cutter Trailing Cable
NSSHKCGEOEU 0.6/1kV Coal Cutter Trailing Cable is a TEBAOFLEX cable for the application and operating conditions identified in the original product record. When selecting an NSSHKCGEOEU Cable, engineers should check machine power, trailing distance, current demand, conductor size, voltage drop, pulling load, torsion, floor condition and bending route. The steel braid and PE/control conductor design are important for moving underground machines, so they should be reviewed together with the grounding system, control circuit and cable handling arrangement. Send the exact size, length, installation duty and documentation requirements for a technical quotation.
NSSHKCGEOEU 0.6/1kV Coal Cutter Trailing Cable is a TEBAOFLEX cable for the application and operating conditions identified in the original product record. When selecting an NSSHKCGEOEU Cable, engineers should check machine power, trailing distance, current demand, conductor size, voltage drop, pulling load, torsion, floor condition and bending route. The steel braid and PE/control conductor design are important for moving underground machines, so they should be reviewed together with the grounding system, control circuit and cable handling arrangement. NSSHKCGEOEU Cable is a 0.6/1kV coal cutter trailing cable for underground mobile machines such as coal shearers, roadheaders, TBMs and LHD scoops. Its EPR insulation, double-concentric PE/control conductor design and steel braid reinforcement support free trailing operation behind moving equipment. The source record places this product in mining & tunneling cables. Before ordering, confirm the exact product variant, conductor or core arrangement, system rating, route conditions, equipment connection and required documentation against the project specification. The requested NSSHKCGEOEU 0.6/1kV Coal Cutter Trailing Cable should be evaluated as a complete cable assembly: review its intended equipment, conductor arrangement, installation method, movement duty, environment, terminations, dimensions and required documentation together.
NSSHKCGEOEU 0.6/1kV Coal Cutter Trailing Cable construction
Cable Construction
- Conductor: Very finely stranded tinned copper conductor.
- PE conductor: Double-concentric control/PE wire spinning in the outer interstice.
- Insulation: EPR-based compound type 3GI3.
- Core identification: Main cores in coloured black, grey and brown; control cores in blue.
- Core arrangement: Three main conductors laid up with double-concentric control/PE conductor elements in the outer interstice.
- Inner sheath: Vulcanized rubber inner sheath, EPR-based GM1B compound.
- Armouring, reinforced build only: Steel strand braid vulcanized between inner and outer sheath. The base NSSHKCGEOEU designation to DIN VDE 0250 Part 812 is supplied without armour; the braid-reinforced build carries the separate designation NSSHKCGERLOEU.
- Outer sheath: Synthetic elastomer compound type 5GM5, yellow.
Designation reference: what NSSHKCGEOEU carries, and what needs the RL designation
Two catalogue versions of this designation, issued as TENAX-VE and SCHRÄM-TENAX-VE to DIN VDE 0250 Part 812, describe the same construction. Three of its elements are what distinguish NSSHKCGEOEU from neighbouring coal cutter designations, and none of them is an armour layer.
| Element | Reference construction | Why it matters on selection |
|---|---|---|
| Lay-up | Cores laid up over a central cradle (saddle) separator made of conducting rubber, with the pilot and earth units in the interstices | The central separator is the model-specific feature; a cable without it is a different construction even at the same size. |
| Earth conductor | Distributed: strands of very fine copper wire around the pilot-core insulation, plus fine stranded tinned copper accommodated in the cradle separator | Distributed rather than concentric, so the termination design has to pick the earth up in two places. |
| Pilot cores | Copper/steel conductors capable of expansion and compression, 3GI3 EPR-based insulating covering, laid in the outer interstices | The copper-steel pilot accommodates cable movement; a plain copper pilot does not. |
| Inner sheath | Conducting rubber compound with counterwound taping | Part of the earth-fault detection path, not just bedding. |
| Armour | None | A steel braid makes the cable NSSHKCGERLOEU, a separate designation with its own dimensions. |
| Bending radius | 1.5 × D fixed installation; 2.5 × D flexing | Markedly tighter than the armoured build, which is 2 × D, 3 × D and 4.5 × D on guide pulleys and drums. |
| Squeezing stress | Meets draft DIN VDE 0472 Part 818, "Behaviour under Squeezing Stress": squeeze damage is detected as an earth fault with the highest achievable reliability | The reason this designation is specified where the cable can be run over or trapped. |
Choosing between the unarmoured and armoured builds
| Property | NSSHKCGEOEU | NSSHKCGERLOEU |
|---|---|---|
| Steel braid | None | Tensile- and torsion-resistant steel-wire braid |
| Minimum bending radius | 1.5 × D fixed; 2.5 × D flexing | 2 × D static; 3 × D flexing; 4.5 × D on guide pulleys and drums |
| Duty it suits | Extreme bending under low tensile stress | High tensile and torsional load, guide pulleys, LHD reeling |
| Reference outer diameter, 3 × 25 mm² build | 39.0-42.0 mm | 41.5-45.0 mm |
The two builds share identical electrical values size for size; only the outer diameter and the weight change, which is what adding the braid does. Select on the route, not on the table: if the cable is pulled, runs over guide pulleys or feeds an LHD reel, the armoured designation applies. For the spiral concentric-earth low-tensile construction without the central separator see NSSHCGEOEU low-tensile coal cutter cable, and for the high-tensile copper-steel braid build see NSSHCGEOEU high-tensile coal cutter cable.
The construction and dimensional data tabulated elsewhere on this page are those of the build TEBAOFLEX supplies against this designation. This reference block is given so that a catalogue designation can be matched element by element; it does not state that the two are equivalent.
Reference note: for enquiries marked TENAX-VE, SCHRÄM-TENAX-VE or the misspelling NSSHKGGEOEU, TEBAOFLEX manufactures to the NSSHKCGEOEU designation and the construction shown, and is not affiliated with the trademark holder.
NSSHKCGEOEU 0.6/1kV Coal Cutter Trailing Cable applications
Applications
- Coal cutter and coal shearer power supply cables.
- Roadheaders, TBMs and LHD scoop underground machine applications.
- Free trailing cable routes behind moving mining machinery.
- Underground equipment requiring combined power, PE and control conductor functions.
- Mining sites where flame resistance, oil resistance and mechanical reinforcement are required.
Selection Notes for Buyers
When selecting an NSSHKCGEOEU Cable, engineers should check machine power, trailing distance, current demand, conductor size, voltage drop, pulling load, torsion, floor condition and bending route. The steel braid and PE/control conductor design are important for moving underground machines, so they should be reviewed together with the grounding system, control circuit and cable handling arrangement.
Selection checks
Confirm the equipment interface, installation method, route length, movement or flexing duty, environmental exposure, conductor or core requirements and project documentation before final selection.
Reference designation cross-reference
This braided coal cutter cable is catalogued under two reference names for the same build.
| Reference designation | TEBAOFLEX designation and build | Rated voltage | What the reference name marks |
|---|---|---|---|
| TENAX-VE / NSSHKCGEOEU | NSSHKCGEOEU coal cutter trailing cable | 0.6/1 kV | The steel strand braid over the core assembly is what the E marks |
| SCHRÄM-TENAX-VE / NSSHKCGEOEU | NSSHKCGEOEU coal cutter trailing cable | 0.6/1 kV | The same build listed for coal cutter machines |
For the full list of reference designations and the TEBAOFLEX build each one maps to, see the mining cable designation cross-reference.
Trademark note: TENAX®, TROMMELFLEX®, FELTOFLEX® and SCHRÄM® are trademarks of their respective owners, and TEBAOFLEX is neither affiliated with those companies nor reselling their cable. What we supply is the equivalent construction: we manufacture to the same VDE type designation and published construction, and every designation listed here can be quoted and supplied as a TEBAOFLEX build. The names appear so that an enquiry written in those terms reaches the matching construction, which is made to the standards and construction confirmed for the order.
NSSHKCGEOEU 0.6/1kV Coal Cutter Trailing Cable specifications
Source-listed technical tables
The tables below retain the original product data, including units, ranges and ordering examples.
| Product Type | Coal cutter trailing cable |
| Model | NSSHKCGEOEU |
| Rated Voltage | 0.6/1kV, 600/1000V |
| Max. AC Operating Voltage | 0.7/1.2kV |
| Max. DC Operating Voltage | 0.9/1.8kV |
| AC Test Voltage | 3kV |
| AC Test Voltage, Control Cores | 2kV |
| Conductor Temperature | 90°C maximum |
| Short-Circuit Temperature | 250°C maximum |
| Fixed Temperature | -40°C to +80°C |
| Fully Flexible Temperature | -20°C to +60°C |
| Travel Speed | 150m/min |
| Standard Basis | DIN VDE 0250-812 |
| Flame Retardant | IEC 60332-1-2 |
| Oil Resistance | IEC 60811-404 |
| Weather Resistance | Indoor and outdoor use; resistant to ozone and moisture |
| Minimum Breaking Load of Steel Braid | 45kN |
| Maximum Tensile Load on Conductor | 40 N/mm² |
| Torsional Stress | ±10°/m |
| Travel Speed | 150m/min |
| Cores x Cross Section | Conductor Diameter | Outer Diameter Min-Max | Weight | Resistance at 20°C | Capacitance | Inductance | Current Capacity | Short Circuit Current |
|---|---|---|---|---|---|---|---|---|
| 3x25 + 3x1.5STKON + 16/3KON | 7.1mm | 39.2 - 42.2mm | 2700kg/km | 0.795 Ω/km | 0.37 μF/km | 0.33 mH/km | 131A | 3.58kA |
| 3x35 + 3x1.5STKON + 16/3KON | 8.4mm | 40.8 - 43.8mm | 3100kg/km | 0.565 Ω/km | 0.42 μF/km | 0.30 mH/km | 162A | 5.01kA |
| 3x50 + 3x1.5STKON + 25/3KON | 10.1mm | 46.2 - 49.2mm | 4000kg/km | 0.393 Ω/km | 0.45 μF/km | 0.28 mH/km | 202A | 7.15kA |
| 3x70 + 3x1.5STKON + 35/3KON | 11.9mm | 49.6 - 53.6mm | 5100kg/km | 0.277 Ω/km | 0.52 μF/km | 0.27 mH/km | 250A | 10.01kA |
| 3x95 + 3x1.5STKON + 50/3KON | 14.0mm | 56.8 - 60.8mm | 6700kg/km | 0.210 Ω/km | 0.55 μF/km | 0.27 mH/km | 301A | 13.59kA |
| 3x120 + 3x1.5STKON + 70/3KON | 15.5mm | 60.6 - 64.6mm | 8000kg/km | 0.164 Ω/km | 0.59 μF/km | 0.26 mH/km | 352A | 17.16kA |
| 3x150 + 3x1.5STKON + 70/3KON | 17.6mm | 67.0 - 71.0mm | 9620kg/km | 0.132 Ω/km | 0.61 μF/km | 0.26 mH/km | 404A | 21.45kA |
| 3x185 + 3x1.5STKON + 95/3KON | 19.1mm | 72.0 - 76.0mm | 11500kg/km | 0.108 Ω/km | 0.63 μF/km | 0.26 mH/km | 461A | 26.46kA |
| 3x240 + 3x1.5STKON + 120/3KON | 22.0mm | 80.4 - 85.4mm | 14600kg/km | 0.0817 Ω/km | 0.67 μF/km | 0.25 mH/km | 540A | 34.32kA |
| 3x300 + 3x1.5STKON + 150/3KON | 24.8mm | 89.1 - 94.1mm | 18700kg/km | 0.0654 Ω/km | 0.70 μF/km | 0.25 mH/km | 620A | 42.9kA |
Original product attributes
These product attributes are retained as supplied and should be checked against the ordered construction.
| Product Type | Coal cutter trailing cable |
|---|---|
| Model | NSSHKCGEOEU |
| Voltage Rating | 0.6/1kV, 600/1000V |
| Max AC Operating Voltage | 0.7/1.2kV |
| Max DC Operating Voltage | 0.9/1.8kV |
| Conductor | Very finely stranded tinned copper conductor |
| Insulation | EPR-based compound type 3GI3 |
| PE/Control Design | Double-concentric control/PE wire spinning in outer interstice |
| Armouring | Steel strand braid vulcanized between inner and outer sheath |
| Outer Sheath | 5GM5 yellow synthetic elastomer compound |
| Flame Retardant | IEC 60332-1-2 |
| Oil Resistant | IEC 60811-404 |
| Fixed Temperature | -40°C to +80°C |
| Flexible Temperature | -20°C to +60°C |
| Steel Braid Breaking Load | 45kN |
| Max Tensile Load | 40 N/mm² |
| Torsional Stress | ±10°/m |
| Travel Speed | 150m/min |
NSSHKCGEOEU 0.6/1kV Coal Cutter Trailing Cable standards and compliance
The following standard references are carried over from the original product record. They identify the source basis and do not replace project-specific certification or inspection requirements.
- Standard Basis DIN VDE 0250-812
- Flame Retardant IEC 60332-1-2
- Oil Resistance IEC 60811-404
Where a project requires a test report, certificate, marking record or inspection release, include that requirement in the quotation request.
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
NSSHKCGERLOEU 0.6/1kV Armoured Coal Cutter Cable
A related cable option for a different application or duty profile.
View productNSSHCGEOEU Low-Tensile Coal Cutter Cable 0.6/1kV
A related cable option for a different application or duty profile.
View productNSSHCGEOEU 0.6/1kV Coal Cutter Cable – High Tensile
A related cable option for a different application or duty profile.