Get a Quote
Submersible Pump Cables TEBAOFLEX

H07RN8-F Cable – 450/750 V Submersible Pump Cable

H07RN8-F cable is a 450/750 V flexible rubber cable for submersible pump connections and wet-site power. The quoted cable must be matched to water type, immersion depth, temperature, core size and sealing method.

  • Class 5 flexible copper reference
  • EI4 rubber insulation and EM2 rubber sheath reference
  • Fresh-water reference limit in current page data: up to 10 m and 40 deg C
  • Confirm joints, glands, current capacity and mechanical protection
  • Do not use for lifting, continuous reeling or seawater without separate evidence
SKU: H07RN8-F Category: Tags: Brand:
Product information
SKU
H07RN8-F
Brand
TEBAOFLEX
Product overview

H07RN8-F Cable for Submersible Pumps and Wet-Site Power

H07RN8-F cable is a 450/750 V flexible rubber cable for supplying submersible pumps and portable equipment in wet industrial locations. Its Class 5 copper conductor, rubber insulation and robust rubber outer sheath support flexible installation where moisture and moderate mechanical stress are expected. For fresh-water immersion, specify the cable only within the verified project limit: up to 10 m depth and a maximum water temperature of 40°C.

This model is a practical choice for pump connections, drainage systems, construction equipment and protected wet-site power runs. It is not a lifting cable and should not be selected for waterways, moving water, shipping traffic, continuous reeling, severe tensile load, seawater or locations where dangerous mechanical damage is likely.

  • Rated voltage: 450/750 V
  • Flexible Class 5 copper conductor
  • Fresh-water use: up to 10 m at no more than 40°C
  • Black rubber outer sheath for demanding wet environments

For an accurate quotation, provide the core count, conductor size, total length, installation route, water depth and temperature, movement duty, gland size and required compliance documents. For deeper immersion, potable-water service, screened motor leads or composite power-and-control designs, compare our submersible pump cable range.

Construction

How Is H07RN8-F Cable Constructed?

The H07RN8-F design combines a flexible Class 5 copper conductor with rubber insulation and a heavy-duty rubber sheath. The construction below describes the harmonized cable type; the quoted TEBAOFLEX build and identification scheme should be confirmed for the selected core count and conductor size.

H07RN8-F three-core rubber cable cross-section showing copper conductors, insulation and black outer sheath
Typical H07RN8-F three-core construction; final markings and dimensions depend on the quoted configuration.
LayerTypical H07RN8-F constructionSelection relevance
ConductorClass 5 flexible bare copper to IEC/EN 60228Supports installation flexibility; select the cross-section by current, voltage drop and starting duty.
InsulationEI4 rubber compoundSeparates and protects each conductor under the cable type’s thermal and electrical limits.
Core identificationColour-coded cores; green/yellow protective conductor where applicableConfirm the required core count and identification for the equipment circuit.
Outer sheathBlack EM2 rubber compoundProvides the external mechanical and environmental protection expected for this harmonized type.

Do not infer chemical, oil, UV, potable-water or hazardous-area approval from the cable appearance alone. Request the applicable declaration, test evidence or project-specific confirmation with the quotation.

Applications

Where Can H07RN8-F Cable Be Used?

H07RN8-F is intended for submersible pump connections and flexible power duties in dry, damp, wet and fresh-water environments, provided the installation stays within the verified depth, temperature, movement and mechanical-load limits.

Suitable selection casesConditions to confirm
Fresh-water submersible pump supplyMaximum 10 m immersion depth and 40°C water temperature; confirm joints, glands and sealing.
Drainage, dewatering and protected wet-site equipmentConfirm voltage, current, voltage drop, cable route and mechanical protection.
Portable tools, generators and workshop equipmentUse within the permitted occasional-movement duty and bending radius.
Protected fixed routing in demanding environmentsConfirm support method, ambient temperature and exposure to oils or chemicals.

Do not specify this cable for

  • Waterways, shipping traffic, moving water or places with a high risk of mechanical damage
  • Immersion deeper than 10 m, seawater service or potable-water approval without separate evidence
  • Lifting, suspension by the cable, continuous reeling, torsion or high-frequency trailing
  • Hazardous areas unless the complete installation and cable documentation meet the required classification

If the project falls outside these boundaries, send the operating conditions with the RFQ so TEBAOFLEX can propose a more suitable pump or motor cable.

Specifications

H07RN8-F Cable Technical Specifications

Use the values below for preliminary selection, then confirm the contractual datasheet for the exact core count and conductor size.

ModelH07RN8-F (also searched as H07RN-8-F)
Rated voltage Uo/U450/750 V
AC test voltage2500 V
ConductorClass 5 flexible bare copper to IEC/EN 60228
Insulation / sheathEI4 rubber / black EM2 rubber
Fixed installation temperature-40°C to +60°C
Flexible-service temperatureExisting TEBAOFLEX source: -15°C to +60°C; current harmonized type references commonly state -25°C to +60°C. Confirm the contractual limit at quotation.
Fresh-water useUp to 10 m depth; maximum water temperature +40°C
Minimum bending radius4 × overall diameter fixed; 6 × overall diameter flexed
Tensile loadType-reference limit up to 15 N/mm² of conductor cross-section; not for lifting or suspension
Flame testIEC/EN 60332-1-2 test method

Recorded configuration range

Core countRecorded conductor-size range
1 core1.5–50 mm²
3 core1.5–50 mm²
4 core1–35 mm²
7 core1.5–2.5 mm²
12 core1.5–2.5 mm²
18, 24 or 36 core1.5 mm²

The configuration range is retained from the existing TEBAOFLEX product data. Overall diameter, copper weight, net weight, current capacity and packing vary by construction and must be confirmed in the quotation.

Standards

H07RN8-F Standards and Verification Scope

H07RN8-F is a harmonized cable designation, but a referenced standard or test method is not the same as a product certificate. Confirm the evidence required by the destination market and project before ordering.

ReferenceScope
EN 50525-2-21Construction basis for harmonized flexible cables with crosslinked elastomeric insulation.
IEC/EN 60228Class 5 conductor construction.
EN 50363-1EI4 insulation compound reference.
EN 50363-2-1EM2 sheath compound reference.
IEC/EN 60332-1-2Single insulated wire or cable vertical flame-propagation test method.
EN 50565-1 / EN 50565-2Selection, installation and application guidance, including water-use boundaries.
IEC/EN 60811, EN 50395 and EN 50396Material, electrical and non-electrical test methods used by current type references.

These references do not by themselves prove TEBAOFLEX certification, regulatory conformity or a declared CPR class for every size. Request the declaration of conformity, certificate, test report, inspection plan or other project documentation required for the exact quoted cable.

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    Optional: attach a cable specification, drawing, data sheet or product image (PDF, DOC, DOCX, XLS, XLSX, CSV, JPG or PNG; maximum 10 MB).

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.