Get a Quote
Marine & Offshore Cables TEBAOFLEX

50 Ohm High-Voltage Coaxial Armoured Tow Cable

50 Ohm High-Voltage Coaxial Armoured Tow Cable brings 1 selectable construction options together for RF, telemetry, video and marine-system engineers. Compare the complete signal, electrical and mechanical requirement before choosing a configuration.

  • Selection focus: match a mechanically reinforced 50 ohm coaxial route to RF, telemetry or video equipment
  • Available configurations: 1
  • Mechanical inputs: cable length, working load, drum, sheave, routing and deployment cycle
  • Quotation inputs: services, environment, termination, quantity and required inspection documents
SKU: 1SSA39 Category: Brand:
Product information
SKU
1SSA39
Brand
TEBAOFLEX
Product overview

50 Ohm High-Voltage Coaxial Armoured Tow Cable selection overview

The 50 Ohm High-Voltage Coaxial Armoured Tow Cable gives RF, telemetry, video and marine-system engineers one clear route for comparing 1 available constructions. It is designed to match a mechanically reinforced 50 ohm coaxial route to RF, telemetry or video equipment. Keeping the options in one product group makes it easier to compare signal architecture, conductor or fibre content, armour, diameter, mechanical load and bend geometry without switching between separate product pages.

Selection starts with the equipment interface: define voltage and current, signal type and frequency, coaxial impedance and allowable attenuation, or fibre type, count and wavelength as applicable. Then define whether the cable will be static, suspended, reeled, towed or repeatedly deployed. Cable length, working load, breaking-load criterion, drum and sheave dimensions, temperature, water environment, abrasion, buoyancy and the connector or moulded termination must be reviewed as one system.

  • Compare: construction, transmission values, outside diameter, load and bend data shown for each option.
  • Confirm: the complete service combination and the operating values that apply at the required cable length.
  • Specify: inspection stages, test methods, acceptance values, marking and documentation in the quotation.

Use the related subsea and marine cable selection page for the wider application route, or send your equipment and deployment requirements for an engineering review.

Construction

50 Ohm High-Voltage Coaxial Armoured Tow Cable construction options

Compare the complete layer sequence for each option. Conductor or fibre elements, insulation, screening, fillers, bedding, strength members, armour and outer sheath are selected together to suit the transmission and deployment duty.
ConfigurationConstruction
50 Ω high-voltage coaxial tow configuration1 × 50 Ω coax; PP; two preformed galvanized steel armour layers

Construction selection

Armour material and lay, sheath material, waterblocking, screening and fibre protection are matched to corrosion exposure, abrasion, repeated bending, handling load and termination design. The armour anchoring and connector or moulded transition are reviewed with the cable because they control how load and water sealing are transferred into the equipment.
Applications

Applications for 50 Ohm High-Voltage Coaxial Armoured Tow Cable

This product group supports RF, telemetry, video and marine-system engineers where transmission performance and mechanical deployment duty must be selected together.
  • Marine RF, telemetry and video systems designed around a verified 50 Ω interface.
  • Winch-deployed instruments where the cable also carries deployment load and the termination anchors the armour correctly.
  • Confirm frequency, allowable attenuation, cable length, drum and sheave dimensions before selecting this route.

Information needed for selection

Provide the equipment, cable length, service voltages or signals, load criterion, winch and sheave dimensions, deployment method, water environment, temperature, buoyancy target, connector or moulding interface and required inspection documents.
Specifications

50 Ohm High-Voltage Coaxial Armoured Tow Cable specifications

Use the stated values to compare complete configuration options. Empty properties are omitted instead of being estimated, and each numerical value stays with the construction under which it is listed.

50 Ω high-voltage coaxial tow configuration

Construction1 × 50 Ω coax; PP; two preformed galvanized steel armour layers
Voltage / test value3000 V
Impedance50 Ω @ 1 MHz
Coaxial attenuation< 5.6 dB/km @ 1 MHz
Outside diameter14.15 mm
Breaking load89 kN
Working load22 kN
Dynamic bend radius280 mm
Temperature-30 to +90°C

Using the values

Breaking load is not the normal operating load. Bend values must match drums, sheaves, guides and connector exits. A voltage entry that includes a duration is a dielectric test value rather than a continuous rated voltage. Confirm the applicable operating and acceptance values in the quotation.
Standards

Standards and test references

The applicable references are selected for the confirmed cable construction and project duty. They provide a framework for engineering and inspection rather than a one-size-fits-all cable designation.
  • IEC 61196-1: General definitions, design requirements and test-method framework for coaxial communication cables.
  • IEC 61196-1-100: General conditions for electrical tests in the IEC 61196 coaxial-cable test series.
  • Project test plan: Defines impedance and attenuation frequency, dielectric test conditions, tensile load, bend method, water exposure and termination checks.
Final test conditions, sample lengths, conditioning, acceptance values, marking and report format are defined in the quotation and inspection plan.
Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    Optional: attach a cable specification, drawing, data sheet or product image (PDF, DOC, DOCX, XLS, XLSX, CSV, JPG or PNG; maximum 10 MB).

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request.

    * Required fields. Please include the key cable or application details for review.