POLYFLEX MINE 0.6/1 kV Heavy-Duty PUR Mining Cable
POLYFLEX MINE 0.6/1 kV heavy-duty PUR mining power cable with Class 5 bare copper, EPR insulation, split protective conductors and yellow PUR sheath for moving quarry, open-cast mining and civil-engineering equipment. RFQ only.
POLYFLEX MINE cable is a 0.6/1 kV heavy-duty PUR mining power cable for mobile equipment and vehicles used in quarrying, open-cast mining, civil engineering, mining and milling sites, construction plants, and industry. Fine-stranded bare copper Class 5 conductors, basic EPR insulation, split protective conductors and a yellow PUR sheath provide a flexible power construction for outdoor moving service.
The data covers fixed and moving applications with a 10 x outside-diameter minimum bending radius, UV resistance, a 90 °C maximum conductor temperature, and stated flame-retardant and halogen-free references. Two listed configurations are 3 x 95 mm² + 3G16 + 2 x 2.5 mm² and 3 x 185 mm² + 3G35 + 2 x 2.5 mm². Confirm part number, route, reel geometry, speed, torsion duty, ampacity basis and destination requirements in the RFQ. The supplied data does not define a numeric travel speed or torsion limit.
For equipment that needs a different reeling construction, compare the 12YHRDT11YH / RXP-D heavy-duty PUR reeling cable and the TRA anti-torsion PUR reeling cable.
Construction
| Layer | Construction detail |
|---|---|
| Conductor | Bare copper, Class 5 fine stranded to DIN EN IEC 60228 (VDE 0295). |
| Insulation | Basic EPR. |
| Protective conductors | Split in the outer interstices. |
| Outer sheath | Yellow polyurethane (PUR). |
| Core identification | Colours according to VDE 0293 (HD 308). |
Applications
- Mobile quarrying and open-cast mining equipment.
- Large civil-engineering vehicles and machinery.
- Mining and milling site power connections.
- Construction plants and industrial mobile equipment.
- Outdoor moving routes where the specified environmental and bending limits are met.
Selection boundary
The supplied data supports moving applications and a 10 x D minimum bending radius. It does not provide a numeric travel speed or torsion limit. For continuous reel systems with defined high-speed or anti-torsion requirements, compare the RXP-D reeling cable or TRA anti-torsion cable.
Specifications
| Parameter | POLYFLEX MINE data |
|---|---|
| Rated voltage U0/U | 0.6/1 kV |
| Maximum three-phase operating voltage | 1.2 kV |
| Maximum conductor temperature | 90 °C |
| Outer cable temperature, fixed | -60 to +90 °C |
| Outer cable temperature, moved | -30 to +90 °C |
| Minimum bending radius | 10 x D fixed and moving |
| Maximum tensile strength at conductor | 15 N/mm² |
| Outdoor / UV | Outdoor use; UV-resistant |
| Part no. | Configuration | R (Ohm/km) | Ampacity in air at 30 °C | Approx. OD | Cu weight (kg/km) | Net weight (kg/km) |
|---|---|---|---|---|---|---|
| 037339 | 3 x 95 mm² + 3G16 + 2 x 2.5 mm² | 0.206 | 298 A | 40.2 mm | 3245 | 4025 |
| 037342 | 3 x 185 mm² + 3G35 + 2 x 2.5 mm² | 0.106 | 456 A | 57.6 mm | 6384 | 8080 |
Dimensions and weights are approximate source values. Ampacity is stated for air at 30 °C. Confirm conductor-resistance temperature basis, production tolerances, ordered length and the applicable installation derating during quotation.
Standards
| Reference | Use in this product data |
|---|---|
| DIN EN IEC 60228 (VDE 0295) | Class 5 fine-stranded copper conductor construction. |
| VDE 0482-332-1-2 / IEC 60332-1-2 | Flame-retardant reference for the cable. |
| DIN EN 50267 / IEC 60754 | Halogen-free reference for the cable. |
| VDE 0293 (HD 308) | Core identification by colour. |
Request a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.