Type 7S BS 6708 640/1100 V Three-Core Pilot Mining Cable
Type 7S mining cable for excavating, crushing and coal-cutting equipment, with the source-defined 640/1100 V rating and 3 kV; 2.5 kV pilot test reference.
- Model: Type 7S
- Conductor and insulation: flexible tinned copper with the insulation and core construction listed for this model in the supplied PDF
- Screen, pilot, earth and armour arrangement preserved from the source datasheet
- Heavy-duty chloroprene or PCP outer protection as listed for this model
- Original Type datasheet available as the product download
Send the equipment, voltage, conductor area, route, quantity and document requirements for an RFQ.
Type 7S for excavating, crushing and coal-cutting equipment
Type 7S mining cable is specified in the supplied BS 6708 datasheet for excavating, crushing and coal-cutting equipment. This page keeps the source-listed voltage, test reference, core functions and dimensional tables together so a procurement engineer can compare the requested model against the cable marking and the equipment connection. The editorial focus is the pilot-unit decision for coalface machinery, not a generic promise of performance.
The supplied construction uses three individually screened phase cores plus one unscreened three-core pilot unit, laid up around the central bare earth conductor and protected by a heavy-duty chloroprene sheath. That arrangement matters because Type 7S uses an unscreened three-core pilot unit, unlike the single pilot arrangements of Type 7 and Type 7M. The family should therefore be selected by model, core function and installation route as well as by voltage. The mining and tunnelling cable range provides the wider TEBAOFLEX product context.
- Choose by: confirm the pilot-unit core count and the separate 2.5 kV pilot test requirement before ordering.
- Confirm before ordering: existing sheath marking, conductor area, cable length, route, support or handling system, terminations and the required inspection documents.
- Do not infer: values not listed in the supplied PDF, such as a different current basis, water/oil/UV performance, certification scope or mechanical interchangeability.
Where a three-core pilot layout is being compared with adjacent models, the BS 6708 mining cable replacement guide provides a useful model-by-model screening checklist.
For a technical quotation, send the equipment nameplate or existing cable marking, voltage and size requirement, installation conditions, quantity, destination and any project-specific test or documentation requirement.
Type 7S construction
The cross-section below is the supplied construction drawing for Type 7S. The ordering decision is driven by Type 7S uses an unscreened three-core pilot unit, unlike the single pilot arrangements of Type 7 and Type 7M.

Source-listed construction
| Construction element | Source-listed value |
|---|---|
| Conductor | Electrolytic stranded tinned copper wire, IEC 60228 Class 5 |
| Insulation | EPR; ground core is not insulated |
| Screen | Tinned copper and nylon braided screen over phase cores; pilot unit is not screened |
| Pilot unit | One unscreened pilot unit with three thinner cores |
| Lay-up | Three phase cores with composite individual screens and one pilot unit laid up in contact with the bare earth conductor in the centre |
| Sheath | Heavy-duty chloroprene outer sheath |
Do not use the drawing as a substitute for the dimensional tables. Confirm the cable end preparation, screen and earth termination, armour bonding and machine interface with the equipment documentation before installation.
Type 7S applications

The supplied datasheet identifies this cable for excavating, crushing and coal-cutting equipment. Google result patterns for the BS 6708 family also separate cables by equipment duty, voltage class, core function and whether the route is armoured, screened, flat or auxiliary. That is why this page keeps the Type 7S construction separate from nearby Type numbers.
- Primary duty: excavating, crushing and coal-cutting equipment.
- Model boundary: Type 7S uses an unscreened three-core pilot unit, unlike the single pilot arrangements of Type 7 and Type 7M.
- Project check: match the cable marking, core map, voltage, termination, route geometry and handling method to the machine drawing.
- Environmental review: confirm the actual mine/quarry conditions and any authority, inspection or documentation requirements; do not infer a certification or material-resistance claim from the model number.
For a nearby screened-pilot option with a different model definition, review the Type 11 mining cable and compare its core map with the equipment documentation before ordering.
The cable should be released only after the equipment route, required length, conductor area, core functions and connection details are agreed. If the intended duty is different from the source-listed application, request an engineering review through the quotation process.
Type 7S specifications
The summary below identifies the supplied model family. The source-transcribed tables that follow retain the PDF's dimensional, electrical and construction values, including available sizes, resistance, current, diameter, mass, bending or pulling data when the PDF provides them.
| Selection item | Source-linked value |
|---|---|
| Model | Type 7S |
| Rated voltage | 640/1100 V |
| Test voltage | 3 kV; 2.5 kV pilot |
| Application | excavating, crushing and coal-cutting equipment |
| Product standard | BS 6708 |
Complete source-transcribed technical tables
Source PDF: BS6708_TYPE_7S_640_1100V_CABLE_datasheet.pdf; 3 pages; 7 extracted tables. Values are not recalculated or replaced by third-party values.
| Parameter | Value |
|---|---|
| Conductor | Electrolytic stranded tinned copper wire, IEC 60228 Class 5 |
| Insulation | EPR insulation; ground core is not insulated |
| Separator | Coloured textile tape for core identification |
| Screen | Tinned copper and nylon braided screen over phase cores; pilot unit is not screened |
| Pilot unit | One unscreened pilot unit with three thinner cores |
| Lay-up | Three phase cores with composite individual screens and one pilot unit laid up in contact with the bare earth conductor in the centre |
| Bedding | Rubber based bedding compound |
| Outer sheath | Heavy duty chloroprene outer sheath |
| Parameter | Value |
|---|---|
| Standard | BS 6708 |
| Rated voltage | 640/1100 V |
| Test voltage | 3 kV; 2.5 kV for pilot cores |
| Cable type | Composite individually screened phase cores with unscreened three-core pilot unit and central bare earth conductor |
| CORE DIMENSIONS | |||||||
|---|---|---|---|---|---|---|---|
| Nominal cross section | Phase conductor | Phase stranding mm | Cond. dia. mm | Insul. dia. mm | Screen dia. mm | Earth conductor | Pilot conductor |
| 3x50+25+3x4 | 3x50 | 396/0.40 | 9.75 | 13.60 | 15.90 | 1x25 | 3x4 |
| 3x70+35+3x6 | 3x70 | 360/0.50 | 11.60 | 15.70 | 18.00 | 1x35 | 3x6 |
| 3x95+50+3x6 | 3x95 | 475/0.50 | 12.75 | 17.25 | 19.55 | 1x50 | 3x6 |
| 3x120+50+3x10 | 3x120 | 608/0.50 | 15.10 | 20.05 | 22.35 | 1x50 | 3x10 |
| 3x150+70+3x10 | 3x150 | 740/0.50 | 17.00 | 22.20 | 24.50 | 1x70 | 3x10 |
| PILOT UNIT DETAILS | |||||
|---|---|---|---|---|---|
| Nominal cross section | Pilot conductors | Pilot stranding mm | Pilot cond. dia. mm | Pilot insul. dia. mm | Pilot unit dia. mm |
| 3x50+25+3x4 | 3x4 | 56/0.30 | 2.60 | 5.55 | 15.60 |
| 3x70+35+3x6 | 3x6 | 84/0.30 | 3.50 | 6.40 | 17.70 |
| 3x95+50+3x6 | 3x6 | 84/0.30 | 3.50 | 6.40 | 19.25 |
| 3x120+50+3x10 | 3x10 | 80/0.40 | 4.40 | 7.30 | 22.05 |
| 3x150+70+3x10 | 3x10 | 80/0.40 | 4.40 | 7.30 | 24.20 |
| CABLE DETAILS | ||||||
|---|---|---|---|---|---|---|
| Nominal cross section | Min. OD mm | Max. OD mm | Min. bend radius mm | Max pulling tension kgf | Approx. weight kg/km | Copper weight kg/km |
| 3x50+25+3x4 | 48.5 | 51.8 | 420 | 1120 | 4450 | 2200 |
| 3x70+35+3x6 | 55.1 | 58.8 | 470 | 1570 | 6080 | 3150 |
| 3x95+50+3x6 | 62.4 | 66.1 | 530 | 2000 | 6650 | 4250 |
| 3x120+50+3x10 | 68.0 | 72.5 | 580 | 2000 | 8300 | 4800 |
| 3x150+70+3x10 | 70.4 | 78.4 | 630 | 2000 | 10500 | 5300 |
| CURRENT RATINGS | ||
|---|---|---|
| Nominal cross section | Continuous current rating at 25 deg C | Intermittent current rating at 25 deg C |
| 3x50+25+3x4 | 170 | 200 |
| 3x70+35+3x6 | 205 | 250 |
| 3x95+50+3x6 | 250 | 310 |
| 3x120+50+3x10 | 295 | 355 |
| 3x150+70+3x10 | 320 | 385 |
| ELECTRICAL DETAILS | |||||||
|---|---|---|---|---|---|---|---|
| Nominal croBss section | Phase DC res. 20 deg C ohm/km | Pilot DC res. 20 deg C ohm/km | Screens+earth res. ohm/km | Reactance 50 Hz ohm/km | Reactance 60 Hz ohm/km | Min. insul. res. Mohm/km | Voltage drop mV/A/m |
| 3x50+25+3x4 | 0.393 | 5.47 | 0.44 | 0.098 | 0.118 | 285 | 0.84 |
| 3x70+35+3x6 | 0.277 | 3.60 | 0.30 | 0.095 | 0.114 | 260 | 0.61 |
| 3x95+50+3x6 | 0.210 | 3.60 | 0.26 | 0.094 | 0.113 | 250 | 0.47 |
| 3x120+50+3x10 | 0.164 | 2.09 | 0.24 | 0.092 | 0.110 | 250 | 0.38 |
| 3x150+70+3x10 | 0.132 | 2.09 | 0.176 | 0.080 | 0.096 | 250 | 0.32 |
Use the table values with the equipment drawing and approved termination plan. If the requested conductor area, current basis, mechanical limit or environmental condition is not listed in the supplied PDF, treat it as a quotation-stage confirmation item.
Type 7S standards and references
| Subject | Source-linked reference |
|---|---|
| Product standard | BS 6708 |
| Rated voltage | 640/1100 V |
| Test voltage | 3 kV; 2.5 kV pilot |
| Source application | excavating, crushing and coal-cutting equipment |
The product page preserves the BS 6708 reference appearing in the supplied PDF. The BSI record currently identifies BS 6708:1998 as withdrawn on 22 May 2026; this status note is a standards-reference update, not a claim that the product is currently certified or approved. See the official BSI BS 6708 scope record for the published status.
For an RFQ, state the required standard documents, inspection scope, test report, cable marking, destination rules and any replacement-equivalence requirement. The model number alone does not establish legal installation compliance.
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
Type 245 Flexible Rubber Mining Cable 1.1–6.6 kV
A related cable option for a different application or duty profile.
View productType 240 Underground Coal Mine Cable 1.1kV to 11kV
A related cable option for a different application or duty profile.
View productType 241.1 Mining Cable 1.1 kV | Type 241 Family
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.