Get a Quote
MINING & TUNNELING CABLES TEBAOFLEX

Type 7S BS 6708 640/1100 V Three-Core Pilot Mining Cable

Type 7S mining cable for excavating, crushing and coal-cutting equipment, with the source-defined 640/1100 V rating and 3 kV; 2.5 kV pilot test reference.

  • Model: Type 7S
  • Conductor and insulation: flexible tinned copper with the insulation and core construction listed for this model in the supplied PDF
  • Screen, pilot, earth and armour arrangement preserved from the source datasheet
  • Heavy-duty chloroprene or PCP outer protection as listed for this model
  • Original Type datasheet available as the product download

Send the equipment, voltage, conductor area, route, quantity and document requirements for an RFQ.

Product information
Brand
TEBAOFLEX
Product overview

Type 7S for excavating, crushing and coal-cutting equipment

Type 7S mining cable is specified in the supplied BS 6708 datasheet for excavating, crushing and coal-cutting equipment. This page keeps the source-listed voltage, test reference, core functions and dimensional tables together so a procurement engineer can compare the requested model against the cable marking and the equipment connection. The editorial focus is the pilot-unit decision for coalface machinery, not a generic promise of performance.

The supplied construction uses three individually screened phase cores plus one unscreened three-core pilot unit, laid up around the central bare earth conductor and protected by a heavy-duty chloroprene sheath. That arrangement matters because Type 7S uses an unscreened three-core pilot unit, unlike the single pilot arrangements of Type 7 and Type 7M. The family should therefore be selected by model, core function and installation route as well as by voltage. The mining and tunnelling cable range provides the wider TEBAOFLEX product context.

  • Choose by: confirm the pilot-unit core count and the separate 2.5 kV pilot test requirement before ordering.
  • Confirm before ordering: existing sheath marking, conductor area, cable length, route, support or handling system, terminations and the required inspection documents.
  • Do not infer: values not listed in the supplied PDF, such as a different current basis, water/oil/UV performance, certification scope or mechanical interchangeability.

Where a three-core pilot layout is being compared with adjacent models, the BS 6708 mining cable replacement guide provides a useful model-by-model screening checklist.

For a technical quotation, send the equipment nameplate or existing cable marking, voltage and size requirement, installation conditions, quantity, destination and any project-specific test or documentation requirement.

Construction

Type 7S construction

The cross-section below is the supplied construction drawing for Type 7S. The ordering decision is driven by Type 7S uses an unscreened three-core pilot unit, unlike the single pilot arrangements of Type 7 and Type 7M.

Type 7S cable cross-section showing the supplied power, pilot, earth, screen and protection arrangement
Supplied Type 7S cross-section; the exact core and armour arrangement must be checked against the product datasheet.

Source-listed construction

Construction elementSource-listed value
ConductorElectrolytic stranded tinned copper wire, IEC 60228 Class 5
InsulationEPR; ground core is not insulated
ScreenTinned copper and nylon braided screen over phase cores; pilot unit is not screened
Pilot unitOne unscreened pilot unit with three thinner cores
Lay-upThree phase cores with composite individual screens and one pilot unit laid up in contact with the bare earth conductor in the centre
SheathHeavy-duty chloroprene outer sheath

Do not use the drawing as a substitute for the dimensional tables. Confirm the cable end preparation, screen and earth termination, armour bonding and machine interface with the equipment documentation before installation.

Applications

Type 7S applications

Type 7S mining cable application with underground longwall mining equipment
Media-library application scene showing underground longwall mining equipment; used for application context, not as a model-specific construction proof.

The supplied datasheet identifies this cable for excavating, crushing and coal-cutting equipment. Google result patterns for the BS 6708 family also separate cables by equipment duty, voltage class, core function and whether the route is armoured, screened, flat or auxiliary. That is why this page keeps the Type 7S construction separate from nearby Type numbers.

  • Primary duty: excavating, crushing and coal-cutting equipment.
  • Model boundary: Type 7S uses an unscreened three-core pilot unit, unlike the single pilot arrangements of Type 7 and Type 7M.
  • Project check: match the cable marking, core map, voltage, termination, route geometry and handling method to the machine drawing.
  • Environmental review: confirm the actual mine/quarry conditions and any authority, inspection or documentation requirements; do not infer a certification or material-resistance claim from the model number.

For a nearby screened-pilot option with a different model definition, review the Type 11 mining cable and compare its core map with the equipment documentation before ordering.

The cable should be released only after the equipment route, required length, conductor area, core functions and connection details are agreed. If the intended duty is different from the source-listed application, request an engineering review through the quotation process.

Specifications

Type 7S specifications

The summary below identifies the supplied model family. The source-transcribed tables that follow retain the PDF's dimensional, electrical and construction values, including available sizes, resistance, current, diameter, mass, bending or pulling data when the PDF provides them.

Selection itemSource-linked value
ModelType 7S
Rated voltage640/1100 V
Test voltage3 kV; 2.5 kV pilot
Applicationexcavating, crushing and coal-cutting equipment
Product standardBS 6708

Complete source-transcribed technical tables

Source PDF: BS6708_TYPE_7S_640_1100V_CABLE_datasheet.pdf; 3 pages; 7 extracted tables. Values are not recalculated or replaced by third-party values.

Source table 1, PDF page 1
ParameterValue
ConductorElectrolytic stranded tinned copper wire, IEC 60228 Class 5
InsulationEPR insulation; ground core is not insulated
SeparatorColoured textile tape for core identification
ScreenTinned copper and nylon braided screen over phase cores; pilot unit is not screened
Pilot unitOne unscreened pilot unit with three thinner cores
Lay-upThree phase cores with composite individual screens and one pilot unit laid up in contact with the bare earth conductor in the centre
BeddingRubber based bedding compound
Outer sheathHeavy duty chloroprene outer sheath
Source table 2, PDF page 1
ParameterValue
StandardBS 6708
Rated voltage640/1100 V
Test voltage3 kV; 2.5 kV for pilot cores
Cable typeComposite individually screened phase cores with unscreened three-core pilot unit and central bare earth conductor
Source table 1, PDF page 2
CORE DIMENSIONS
Nominal cross sectionPhase conductorPhase stranding mmCond. dia. mmInsul. dia. mmScreen dia. mmEarth conductorPilot conductor
3x50+25+3x43x50396/0.409.7513.6015.901x253x4
3x70+35+3x63x70360/0.5011.6015.7018.001x353x6
3x95+50+3x63x95475/0.5012.7517.2519.551x503x6
3x120+50+3x103x120608/0.5015.1020.0522.351x503x10
3x150+70+3x103x150740/0.5017.0022.2024.501x703x10
Source table 2, PDF page 2
PILOT UNIT DETAILS
Nominal cross sectionPilot conductorsPilot stranding mmPilot cond. dia. mmPilot insul. dia. mmPilot unit dia. mm
3x50+25+3x43x456/0.302.605.5515.60
3x70+35+3x63x684/0.303.506.4017.70
3x95+50+3x63x684/0.303.506.4019.25
3x120+50+3x103x1080/0.404.407.3022.05
3x150+70+3x103x1080/0.404.407.3024.20
Source table 3, PDF page 2
CABLE DETAILS
Nominal cross sectionMin. OD mmMax. OD mmMin. bend radius mmMax pulling tension kgfApprox. weight kg/kmCopper weight kg/km
3x50+25+3x448.551.8420112044502200
3x70+35+3x655.158.8470157060803150
3x95+50+3x662.466.1530200066504250
3x120+50+3x1068.072.5580200083004800
3x150+70+3x1070.478.46302000105005300
Source table 1, PDF page 3
CURRENT RATINGS
Nominal cross sectionContinuous current rating at 25 deg CIntermittent current rating at 25 deg C
3x50+25+3x4170200
3x70+35+3x6205250
3x95+50+3x6250310
3x120+50+3x10295355
3x150+70+3x10320385
Source table 2, PDF page 3
ELECTRICAL DETAILS
Nominal croBss sectionPhase DC res. 20 deg C ohm/kmPilot DC res. 20 deg C ohm/kmScreens+earth res. ohm/kmReactance 50 Hz ohm/kmReactance 60 Hz ohm/kmMin. insul. res. Mohm/kmVoltage drop mV/A/m
3x50+25+3x40.3935.470.440.0980.1182850.84
3x70+35+3x60.2773.600.300.0950.1142600.61
3x95+50+3x60.2103.600.260.0940.1132500.47
3x120+50+3x100.1642.090.240.0920.1102500.38
3x150+70+3x100.1322.090.1760.0800.0962500.32

Use the table values with the equipment drawing and approved termination plan. If the requested conductor area, current basis, mechanical limit or environmental condition is not listed in the supplied PDF, treat it as a quotation-stage confirmation item.

Standards

Type 7S standards and references

SubjectSource-linked reference
Product standardBS 6708
Rated voltage640/1100 V
Test voltage3 kV; 2.5 kV pilot
Source applicationexcavating, crushing and coal-cutting equipment

The product page preserves the BS 6708 reference appearing in the supplied PDF. The BSI record currently identifies BS 6708:1998 as withdrawn on 22 May 2026; this status note is a standards-reference update, not a claim that the product is currently certified or approved. See the official BSI BS 6708 scope record for the published status.

For an RFQ, state the required standard documents, inspection scope, test report, cable marking, destination rules and any replacement-equivalence requirement. The model number alone does not establish legal installation compliance.

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    Optional: attach a cable specification, drawing, data sheet or product image (PDF, DOC, DOCX, XLS, XLSX, CSV, JPG or PNG; maximum 10 MB).

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.