Submersible Pump Cables TEBAOFLEX

S07BQ-F Cable 450/750 V – PUR Submersible Pump Cable

S07BQ-F cable is an unscreened 450/750 V flexible cable for submersible motor pumps, with bare-copper conductors, XLPE core insulation and a yellow PUR outer sheath.

  • Rated voltage: U₀/U 450/750 V.
  • Conductors: fine-wire class 5 bare copper.
  • Insulation / sheath: XLPE / PUR, yellow RAL 1021.
  • Size schedule: 10 configurations from 4 G 1.5 to 4 G 16 mm², including 5-, 7- and 10-core options.
  • Minimum bend radius: 5 × cable diameter fixed; 7.5 × cable diameter in flexible use.
  • Conductor temperature: maximum 90 °C.

Send the pump operating conditions for a technical quotation. Immersion and application-specific limits are provided after enquiry.

Product information
Brand
TEBAOFLEX
Product overview

S07BQ-F cable for submersible motor pumps

TEBAOFLEX S07BQ-F is a 450/750 V unscreened cable for submersible motor pumps. Fine-wire bare-copper conductors, XLPE core insulation and a yellow PUR outer sheath form the construction described on this page. The size schedule covers ten configurations with 4, 5, 7 or 10 cores, including a green/yellow protective-earth conductor.

For a pump connection, the complete cable configuration matters as much as the model name. The selected cores must match the motor and auxiliary circuits, while the overall diameter must fit the pump entry and sealing arrangement. Compare the listed diameter and cable mass before confirming a replacement, especially where the route passes through a gland, guide or confined connection space.

The specification tables keep rated voltage, voltage-test data, temperature limits and bending requirements separate. They also identify the difference between fixed routing and flexible use. This helps an equipment buyer check the electrical connection and cable route together without treating a test voltage as a continuous operating rating.

Immersion depth, liquid-temperature limits and other application-specific parameters are provided after enquiry, based on the operating conditions. Share the liquid and pump duty to support that review. The stated operating-temperature range is not a separate water-temperature rating. An unscreened construction also needs to be checked against any motor-drive and electromagnetic-compatibility requirements.

Compare other constructions in our submersible pump cable range, then use the selected S07BQ-F size and installation details when requesting a quotation.

Construction

Construction

The yellow XLPE/PUR S07BQ-F construction combines flexible bare-copper conductors with individually insulated cores. The representative seven-core arrangement includes one green/yellow protective-earth core; it does not represent seven phase conductors.

S07BQ-F seven-core cross-section showing six black XLPE cores, one green-yellow earth core, central packing and yellow PUR sheath
Illustrative seven-core arrangement: six black cores and one green/yellow protective-earth core around central packing. Fine conductor strands and layer dimensions are schematic; final geometry follows the approved drawing.
S07BQ-F 450/750 V cable construction
ComponentConstruction detail
ConductorsFine-wire bare copper, class 5 according to DIN EN 60228 / VDE 0295 / IEC 60228.
Core insulationSpecial compound based on cross-linked polyethylene (XLPE).
Core identificationColours according to CENELEC HD 308 S2, or consecutively numbered black cores with a green/yellow protective-earth conductor.
Core assemblyInsulated cores stranded together with an appropriate lay length. The representative seven-core illustration shows central nonmetallic packing.
ScreeningUnscreened construction.
Outer sheathSpecial polyurethane (PUR) compound, yellow RAL 1021.

The central white element in the illustration is packing. Select the complete core configuration from the size schedule; core count and assembly geometry vary with the selected size.

Applications

Applications

S07BQ-F is intended for flexible electrical connections to submersible motor pumps. Select the conductor cross-section and circuit allocation for the motor and any auxiliary connections, then review the cable route and pump-entry seal.

Yellow S07BQ-F power cable routed to a submersible pump with a separate lifting chain
AI-generated application illustration of a pump connection. The lifting chain supports the pump; the electrical cable is routed separately and is not a lifting element.

Review the pump connection

  • Immersion conditions: immersion depth, liquid-temperature limits and other application-specific parameters are provided after enquiry, based on the operating conditions.
  • Cable entry: match the selected cable diameter to the pump gland or sealing assembly and provide suitable strain relief.
  • Routing: use at least 5 × cable diameter for fixed bends and 7.5 × cable diameter where the cable flexes. Avoid sharp edges and concentrated loads at the entry.
  • Mechanical support: use the pump's designated lifting and support arrangement. Do not lift or suspend the pump by its electrical cable.
  • Electrical selection: confirm the loaded cores, motor starting conditions, cable length and installation conditions when checking conductor size and voltage drop.

Unscreened cable and motor drives

This construction has no electrical screen. Where the pump is supplied by a variable-frequency drive, check the drive manufacturer's cable, grounding and EMC requirements before selection. A matching voltage and conductor size alone do not establish suitability for a drive installation.

Replacement information

Send the full S07BQ-F core configuration, cable length and pump operating conditions with the enquiry. Keep the 450/750 V rating and yellow XLPE/PUR construction together when comparing replacement options.

Specifications

S07BQ-F cable specifications

The values below describe the yellow XLPE/PUR, unscreened 450/750 V construction. D means the overall cable diameter; bending values are radii, not bend diameters.

S07BQ-F 450/750 V electrical, thermal and bending data
Model and constructionS07BQ-F; yellow XLPE/PUR unscreened submersible motor pump cable
Rated voltage U₀/U450/750 V
AC test voltage3,000 V at 50 Hz; a test value, not the continuous operating rating
Conductor class and materialClass 5 fine-wire bare copper
Core insulationXLPE
Outer sheathPUR, yellow RAL 1021
ScreenNone
Operating-temperature range−40 to +90 °C
Maximum conductor operating temperature90 °C
Maximum short-circuit conductor temperature200 °C
Minimum bending radius — fixed installation5 × D
Minimum bending radius — flexible use7.5 × D
Immersion and application-specific limitsProvided after enquiry for the specified operating conditions

The operating-temperature range is separate from the liquid-temperature limit provided after enquiry. Current capacity and permissible short-circuit current depend on the conductor size, circuit and installation conditions.

Core configurations, dimensions and weight

G indicates that the total core count includes a green/yellow protective-earth conductor. The number after G is the nominal cross-section of each conductor in mm²; for example, 7 G 1.5 means seven 1.5 mm² cores in total, including the protective-earth core.

S07BQ-F 450/750 V size schedule — dimensions in mm; copper value and cable weight in kg/km
Model + core configuration (mm²)Approx. outer diameter (mm)Cu-value (kg/km)Approx. cable weight (kg/km)
S07BQ-F 4 G 1.510.157.6126
S07BQ-F 5 G 1.511.172152
S07BQ-F 7 G 1.513.3100.8212
S07BQ-F 10 G 1.515.7144291
S07BQ-F 4 G 2.511.596180
S07BQ-F 7 G 2.516.8168340
S07BQ-F 4 G 414.1153.6270
S07BQ-F 4 G 616.6230.4385
S07BQ-F 4 G 1021.5384662
S07BQ-F 4 G 1625.1614.4958

Diameters and cable weights are approximate reference values. Confirm the final dimensions against the selected pump entry and approved cable drawing. The Cu-value is the catalogue copper value per kilometre, separate from the total cable weight.

Standards

Standards

The following references apply to conductor construction and core identification for the S07BQ-F configuration described here.

S07BQ-F conductor and core-identification references
ReferenceScope in this cable specification
IEC 60228Class 5 flexible conductor construction, including conductor wire and resistance requirements.
DIN EN 60228 / VDE 0295Conductor reference stated for the fine-wire bare-copper construction.
CENELEC HD 308 S2Colour identification of insulated cores where the colour-coded option is used; the alternative is consecutively numbered black cores with a green/yellow protective-earth core.

The official IEC 60228 conductor-standard scope explains its coverage of nominal cross-sections, conductor wires and electrical resistance.

Order and inspection details

State the required standard editions, core-identification option, dimensional checks, conductor checks and voltage-test documentation with the order. Agree the pump sealing arrangement and operating conditions as part of the application review.

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.