S07BQ-F Cable 450/750 V – PUR Submersible Pump Cable
S07BQ-F cable is an unscreened 450/750 V flexible cable for submersible motor pumps, with bare-copper conductors, XLPE core insulation and a yellow PUR outer sheath.
- Rated voltage: U₀/U 450/750 V.
- Conductors: fine-wire class 5 bare copper.
- Insulation / sheath: XLPE / PUR, yellow RAL 1021.
- Size schedule: 10 configurations from 4 G 1.5 to 4 G 16 mm², including 5-, 7- and 10-core options.
- Minimum bend radius: 5 × cable diameter fixed; 7.5 × cable diameter in flexible use.
- Conductor temperature: maximum 90 °C.
Send the pump operating conditions for a technical quotation. Immersion and application-specific limits are provided after enquiry.
S07BQ-F cable for submersible motor pumps
TEBAOFLEX S07BQ-F is a 450/750 V unscreened cable for submersible motor pumps. Fine-wire bare-copper conductors, XLPE core insulation and a yellow PUR outer sheath form the construction described on this page. The size schedule covers ten configurations with 4, 5, 7 or 10 cores, including a green/yellow protective-earth conductor.
For a pump connection, the complete cable configuration matters as much as the model name. The selected cores must match the motor and auxiliary circuits, while the overall diameter must fit the pump entry and sealing arrangement. Compare the listed diameter and cable mass before confirming a replacement, especially where the route passes through a gland, guide or confined connection space.
The specification tables keep rated voltage, voltage-test data, temperature limits and bending requirements separate. They also identify the difference between fixed routing and flexible use. This helps an equipment buyer check the electrical connection and cable route together without treating a test voltage as a continuous operating rating.
Immersion depth, liquid-temperature limits and other application-specific parameters are provided after enquiry, based on the operating conditions. Share the liquid and pump duty to support that review. The stated operating-temperature range is not a separate water-temperature rating. An unscreened construction also needs to be checked against any motor-drive and electromagnetic-compatibility requirements.
Compare other constructions in our submersible pump cable range, then use the selected S07BQ-F size and installation details when requesting a quotation.
Construction
The yellow XLPE/PUR S07BQ-F construction combines flexible bare-copper conductors with individually insulated cores. The representative seven-core arrangement includes one green/yellow protective-earth core; it does not represent seven phase conductors.

| Component | Construction detail |
|---|---|
| Conductors | Fine-wire bare copper, class 5 according to DIN EN 60228 / VDE 0295 / IEC 60228. |
| Core insulation | Special compound based on cross-linked polyethylene (XLPE). |
| Core identification | Colours according to CENELEC HD 308 S2, or consecutively numbered black cores with a green/yellow protective-earth conductor. |
| Core assembly | Insulated cores stranded together with an appropriate lay length. The representative seven-core illustration shows central nonmetallic packing. |
| Screening | Unscreened construction. |
| Outer sheath | Special polyurethane (PUR) compound, yellow RAL 1021. |
The central white element in the illustration is packing. Select the complete core configuration from the size schedule; core count and assembly geometry vary with the selected size.
Applications
S07BQ-F is intended for flexible electrical connections to submersible motor pumps. Select the conductor cross-section and circuit allocation for the motor and any auxiliary connections, then review the cable route and pump-entry seal.

Review the pump connection
- Immersion conditions: immersion depth, liquid-temperature limits and other application-specific parameters are provided after enquiry, based on the operating conditions.
- Cable entry: match the selected cable diameter to the pump gland or sealing assembly and provide suitable strain relief.
- Routing: use at least 5 × cable diameter for fixed bends and 7.5 × cable diameter where the cable flexes. Avoid sharp edges and concentrated loads at the entry.
- Mechanical support: use the pump's designated lifting and support arrangement. Do not lift or suspend the pump by its electrical cable.
- Electrical selection: confirm the loaded cores, motor starting conditions, cable length and installation conditions when checking conductor size and voltage drop.
Unscreened cable and motor drives
This construction has no electrical screen. Where the pump is supplied by a variable-frequency drive, check the drive manufacturer's cable, grounding and EMC requirements before selection. A matching voltage and conductor size alone do not establish suitability for a drive installation.
Replacement information
Send the full S07BQ-F core configuration, cable length and pump operating conditions with the enquiry. Keep the 450/750 V rating and yellow XLPE/PUR construction together when comparing replacement options.
S07BQ-F cable specifications
The values below describe the yellow XLPE/PUR, unscreened 450/750 V construction. D means the overall cable diameter; bending values are radii, not bend diameters.
| Model and construction | S07BQ-F; yellow XLPE/PUR unscreened submersible motor pump cable |
|---|---|
| Rated voltage U₀/U | 450/750 V |
| AC test voltage | 3,000 V at 50 Hz; a test value, not the continuous operating rating |
| Conductor class and material | Class 5 fine-wire bare copper |
| Core insulation | XLPE |
| Outer sheath | PUR, yellow RAL 1021 |
| Screen | None |
| Operating-temperature range | −40 to +90 °C |
| Maximum conductor operating temperature | 90 °C |
| Maximum short-circuit conductor temperature | 200 °C |
| Minimum bending radius — fixed installation | 5 × D |
| Minimum bending radius — flexible use | 7.5 × D |
| Immersion and application-specific limits | Provided after enquiry for the specified operating conditions |
The operating-temperature range is separate from the liquid-temperature limit provided after enquiry. Current capacity and permissible short-circuit current depend on the conductor size, circuit and installation conditions.
Core configurations, dimensions and weight
G indicates that the total core count includes a green/yellow protective-earth conductor. The number after G is the nominal cross-section of each conductor in mm²; for example, 7 G 1.5 means seven 1.5 mm² cores in total, including the protective-earth core.
| Model + core configuration (mm²) | Approx. outer diameter (mm) | Cu-value (kg/km) | Approx. cable weight (kg/km) |
|---|---|---|---|
| S07BQ-F 4 G 1.5 | 10.1 | 57.6 | 126 |
| S07BQ-F 5 G 1.5 | 11.1 | 72 | 152 |
| S07BQ-F 7 G 1.5 | 13.3 | 100.8 | 212 |
| S07BQ-F 10 G 1.5 | 15.7 | 144 | 291 |
| S07BQ-F 4 G 2.5 | 11.5 | 96 | 180 |
| S07BQ-F 7 G 2.5 | 16.8 | 168 | 340 |
| S07BQ-F 4 G 4 | 14.1 | 153.6 | 270 |
| S07BQ-F 4 G 6 | 16.6 | 230.4 | 385 |
| S07BQ-F 4 G 10 | 21.5 | 384 | 662 |
| S07BQ-F 4 G 16 | 25.1 | 614.4 | 958 |
Diameters and cable weights are approximate reference values. Confirm the final dimensions against the selected pump entry and approved cable drawing. The Cu-value is the catalogue copper value per kilometre, separate from the total cable weight.
Standards
The following references apply to conductor construction and core identification for the S07BQ-F configuration described here.
| Reference | Scope in this cable specification |
|---|---|
| IEC 60228 | Class 5 flexible conductor construction, including conductor wire and resistance requirements. |
| DIN EN 60228 / VDE 0295 | Conductor reference stated for the fine-wire bare-copper construction. |
| CENELEC HD 308 S2 | Colour identification of insulated cores where the colour-coded option is used; the alternative is consecutively numbered black cores with a green/yellow protective-earth core. |
The official IEC 60228 conductor-standard scope explains its coverage of nominal cross-sections, conductor wires and electrical resistance.
Order and inspection details
State the required standard editions, core-identification option, dimensional checks, conductor checks and voltage-test documentation with the order. Agree the pump sealing arrangement and operating conditions as part of the application review.
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
H07RN8-F Cable - 450/750 V Submersible Pump Cable
A related cable option for a different application or duty profile.
View productH05BQ-F / H07BQ-F PUR Flexible Cable
A related cable option for a different application or duty profile.
View productSubmersible Pump Motor Cable 450/750V 0.6/1kV with Control Cores
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.