High Voltage DC & Test Cables TEBAOFLEX

PFA High Voltage Wire, 2 kV DC

PFA high voltage wire is an unshielded 2 kV DC equipment wire with silver-plated or nickel-plated stranded copper. Select the conductor plating for the required fixed-installation temperature.

  • Rated voltage: 2 kV DC; test voltage: 4 kV DC.
  • Sizes: 26 AWG or 24 AWG, in the three tabulated configurations.
  • Insulation: PFA; colour: black.
  • Silver-plated copper: −100 to +205°C in fixed installation.
  • Nickel-plated copper: −100 to +250°C in fixed installation.
  • Minimum bend radius: 4 × outer diameter fixed; 8 × moving.

State the plating, temperature, operating duration, conductor size and length when requesting a quotation.

Product information
Brand
TEBAOFLEX
Product overview

PFA high voltage wire for hot and cold equipment wiring

PFA high voltage wire in this family is an unshielded, single-conductor wire rated 2 kV DC for internal equipment connections. PFA insulation surrounds silver-plated or nickel-plated stranded copper in 26 AWG and 24 AWG configurations. The fixed-installation temperature limit is tied to conductor plating: silver-plated versions cover −100 to +205°C, while the nickel-plated 24 AWG version covers −100 to +250°C.

The main selection decision is therefore the complete wire construction, not the insulation name alone. Two 24 AWG wires can have the same finished diameter and different temperature limits. The smaller 26 AWG configuration also differs in strand count and diameter, which matters at a compact feedthrough or termination.

  • Choose by environment: identify the actual hot or cold zone and the substances that can contact the insulation.
  • Choose by routing: match the outer diameter, bend radius and terminal geometry to the available space.
  • Choose by duty: distinguish intermittent test operation from continuous voltage exposure before releasing the wire specification.

For continuous operation, voltage derating is recommended and suitability must be validated in the application. The 4 kV DC test value is a verification condition, separate from the 2 kV DC rated value. Browse High Voltage DC & Test Cables for other insulation and screening choices, or review how wire insulation temperature ratings are defined before comparing materials.

Construction

Construction

The construction comprises one plated stranded copper conductor and PFA insulation. Conductor plating and stranding identify the three configurations.

PFA high voltage wire cross-section showing stranded conductor and pfa insulation
Representative cross-section: stranded conductor and pfa insulation. Layer dimensions and strand count are schematic.
PFA wire construction by element
ElementSpecification
ConductorStranded copper with silver or nickel plating, according to configuration
Stranding26 AWG: 7/34; 24 AWG: 19/36 (strand count/strand AWG)
InsulationPFA (perfluoroalkoxy)
Insulation colourBlack
ScreenUnshielded

Plating is part of the temperature specification

The silver-plated 26 AWG and 24 AWG wires share the +205°C fixed-installation limit. The +250°C limit belongs to the nickel-plated 24 AWG configuration. State the plating in the enquiry and drawing, even when the conductor size and finished diameter appear identical.

Applications

Applications

This PFA wire family suits internal equipment connections in hot or cold zones and compact routes where the insulation may encounter oils, moisture or chemicals. Identify the actual exposure conditions when evaluating the selected configuration.

PFA insulated leads routed to ceramic terminals in a temperature test fixture
Illustrative equipment connection; cable routing and terminations must follow the approved equipment design.
  • Hot-zone wiring: select silver or nickel plating using the applicable fixed-installation limit.
  • Cold equipment zones: account for the stated fixed-installation lower temperature limit and the actual handling conditions.
  • Confined equipment spaces: select the tabulated diameter and conductor stranding for the feedthrough and termination.
  • Oil or chemical exposure: review the actual substance, concentration, temperature and exposure duration for the equipment.

Continuous-duty and movement checks

For continuous use, derating the operating voltage is recommended; validate the cable in the intended application. No universal derating factor is specified. State the working waveform and duration separately from the dielectric test requirement.

The temperature ranges in Specifications apply to fixed installations. For moving service, include the working temperature, bend radius and expected cycles in the enquiry. This construction is intended for equipment and test wiring.

Specifications

Specifications

The following data describe the three 2 kV DC PFA wire configurations. Keep the conductor plating and installation condition beside each temperature value when specifying a variant.

PFA high voltage wire electrical and mechanical data
PropertyValue or condition
Rated voltage2 kV DC
Test voltage4 kV DC
Minimum bend radius, fixed4 × outer diameter
Minimum bend radius, moving8 × outer diameter
Silver-plated copper temperature−100 to +205°C, fixed installation
Nickel-plated copper temperature−100 to +250°C, fixed installation
Environmental resistanceUV, ozone, weather and oil
Continuous-operation conditionVoltage derating recommended for continuous use; validate suitability in the application

Conductor, diameter and temperature configurations

PFA wire 2 kV DC configurations; temperature ranges apply to fixed installation
ConfigurationAWGStrands (number/AWG)Copper platingOuter diameter (mm)Fixed-installation temperature
PFA wire 2 kV DC / 26 AWG / silver-plated267/34Silver1.30 ±0.10−100 to +205°C
PFA wire 2 kV DC / 24 AWG / silver-plated2419/36Silver3.10 ±0.15−100 to +205°C
PFA wire 2 kV DC / 24 AWG / nickel-plated2419/36Nickel3.10 ±0.15−100 to +250°C

Read diameter and voltage independently

The 26 AWG wire has a nominal outer diameter of 1.30 mm, while both 24 AWG configurations have a nominal diameter of 3.10 mm. Preserve the stated tolerances when checking a feedthrough. The diameter difference does not change the tabulated 2 kV DC rating.

For a quotation, identify the complete configuration, length, operating voltage and duration, expected current, thermal zone, routing and required inspection documents. For project dielectric testing, specify the test duration, connections and acceptance criteria alongside the listed 4 kV DC test voltage.

Standards

Standards

Declared compliance and dielectric test data
ItemRequirement or value
RoHSCompliant
DC dielectric test voltage4 kV DC

The European Commission explains the RoHS substance restrictions for electrical and electronic equipment. Include the applicable declaration and inspection-document requirements with the enquiry.

For dielectric acceptance testing, state the test duration, specimen or completed-assembly scope, test connections and pass criteria. The test voltage and the rated operating voltage remain separate values.

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.