Submersible Pump Cables TEBAOFLEX

TML Type B Round and Flat Submersible Pump Cable

TML Type B is a 0.6/1 kV flexible submersible pump cable family for water pumps, water-level lowering and booster systems.

  • 0.6/1 kV
  • EPR core insulation and a blue EM6-type EPR sheath
  • Class 5 plain copper conductors
  • 90 °C maximum conductor temperature
  • Round and flat versions with separate dimension tables
Product information
Brand
TEBAOFLEX
Product overview

TML Type B is a 0.6/1 kV flexible submersible pump cable family for water pumps, water-level lowering and booster systems. The construction presented here uses Class 5 plain copper conductors, EPR core insulation and a blue EM6-type EPR sheath. Round and flat versions share this material system and have separate geometric tables.

Select the cable shape from the pump entry and the supported route. The round table lists nominal outside diameter and the corresponding fixed and moving bending radii. The flat table lists height and width limits, making it useful for checking narrow spaces beside a riser or inside a well casing.

The configuration designation identifies conductor size and protective-earth provision. Match that arrangement to the motor connection before comparing current ratings. Air and fully immersed current data retain separate 30 °C reference conditions; assess exposed and submerged sections of the same route together when sizing the conductors.

Cable mass and tensile-force values also help plan installation handling and the independent support system. Position supports and strain relief so the cable follows natural bends into the entry and carries no pump lifting load. For a quotation, send the required round or flat profile, conductor arrangement, motor duty, length, entry drawing and water-contact requirements. Water depth and water-temperature limits are confirmed for the project after enquiry. The selected 0.6/1 kV construction uses a 3 kV AC test for five minutes.

Construction

Construction

Cable layers are listed from the conductor to the outer sheath.

TML Type B round four-core cross-section with fine copper strands and blue EPR sheath
Representative TML Type B round four-core construction.
TML Type B flat four-core cross-section showing fine copper strands, EPR insulation and blue EPR sheath
Representative TML Type B flat four-core construction.
Cable layers
LayerConstruction
ConductorPlain annealed flexible copper, Class 5 to IEC 60228.
InsulationEPR rubber on each core.
GeometryRound and flat assemblies are listed separately. Three- and four-core flat versions place all cores in one row.
Outer sheathBlue water-resistant EM6-type EPR rubber.
Applications

Applications

Use this construction for submersible water pumps, water-level lowering and booster systems. Match the cable to the actual equipment, route and water medium before selecting the final configuration.

Blue pump cable supported on a fixed post between a closed control cabinet and a sealed water-supply wellhead
Application illustration: supported motor-cable route between a closed control cabinet and a sealed water-supply wellhead.
  • Choose round or flat geometry from the motor entry and available installation clearance.
  • Round-table diameter is nominal; flat-table dimensions have separate height and width limits.
  • Check protective-earth designation and current conditions before comparing two configurations.

Use a supported route under medium mechanical stress. Exclude explosion-hazard locations and water containing more than 0.5 mg/l chlorine for this construction. Review other aggressive water compositions individually.

Choosing round or flat TML Type B

Choosing round or flat TML Type B
Selection pointDesign input
RoundNominal diameter suits circular entries; use the round configuration’s listed bend radii.
FlatHeight and width limits suit profile-based clearance and sealing checks.
Route sizingKeep air and immersed current conditions separate when assessing the route.
HandlingUse the selected row’s mass and tensile force to plan supports and installation.

Related selection resources

Specifications

Specifications

Electrical and operating parameters
ParameterValue
Rated voltage U₀/U0.6/1 kV
ConductorPlain flexible copper, Class 5
Insulation and sheathEPR core insulation and a blue EM6-type EPR sheath
Maximum conductor temperature90 °C
Ambient / handling conditions−40 °C fixed; −25 °C flexible
Water depth and water temperatureProject operating conditions reviewed with the enquiry.
Short-circuit conductor temperature250 °C
Maximum permissible operating voltage AC0.7/1.2 kV
Maximum permissible operating voltage DC0.9/1.8 kV

Current values are for continuous DC or 50–60 Hz AC with the stated loaded-core arrangement. Air reference temperature is 30 °C; water values require complete immersion at 30 °C.

TML Type B round dimensions and electrical data

TML Type B round configuration table
Configuration (mm²)Nominal OD (mm)Minimum fixed bend radius (mm)Minimum moving bend radius (mm)Approximate mass (kg/km)Maximum tensile force (N)Current in air at 30 °C (A)Current fully immersed at 30 °C (A)Conductor short-circuit current, 1 s (kA)
TML Type B round 1 × 1.562436502333400.21
TML Type B round 1 × 2.56.626.439.6653843520.36
TML Type B round 1 × 47.53045906059700.57
TML Type B round 1 × 68.333.249.81209076910.86
TML Type B round 1 × 1010.140.460.61851501061271.43
TML Type B round 1 × 1611.345.267.82552401421702.29
TML Type B round 1 × 2513.554813653751882253.58
TML Type B round 1 × 3515.260.891.24905252322785.01
TML Type B round 1 × 5017.5701056907502893477.15
TML Type B round 1 × 7020.381.2121.8920105035842910
TML Type B round 1 × 9522.790.8136.21210142543151713.6
TML Type B round 1 × 12024.5981471455180050460517.2
TML Type B round 1 × 150281121681825225057869421.5
TML Type B round 1 × 185301201802160277566079226.5
TML Type B round 2 × 18.232.849.2953019230.14
TML Type B round 3 × 0.7583248903416190.11
TML Type B round 3 × 1.59.738.858.21356824290.21
TML Type B round 3 × 2.511.445.668.421011332380.36
TML Type B round 3 × 413527828018043520.57
TML Type B round 3 × 614.5588737027056670.86
TML Type B round 3 × 10208012065045078931.43
TML Type B round 3 × 1624961449407201041252.29
TML Type B round 3 × 2527.7110.8166.2132011251381653.58
TML Type B round 3 × 3531124186173015751712055.01
TML Type B round 3 × 5036144216244022502132557.15
TML Type B round 4G1.510.742.864.21659024290.21
TML Type B round 4G2.512.650.475.623515032380.36
TML Type B round 4G414.457.686.433524043520.57
TML Type B round 4G616.264.897.246036056670.86
TML Type B round 4G1021.987.6131.480060078931.43
TML Type B round 4G1626.2104.8157.211659601041252.29
TML Type B round 4G2530.2120.8181.2165015001381653.58
TML Type B round 4G3534.5138207220021001712055.01
TML Type B round 4G5041.4165.6248.4326030002132557.15
TML Type B round 4G7045.7182.8274.24149420026331610

TML Type B flat dimensions and electrical data

TML Type B flat configuration table
Configuration (mm²)Height minimum (mm)Height maximum (mm)Width minimum (mm)Width maximum (mm)Approximate mass (kg/km)Maximum tensile force (N)Current in air at 30 °C (A)Current fully immersed at 30 °C (A)Conductor short-circuit current, 1 s (kA)
TML Type B flat 3G1.56.36.712.913.51406824290.21
TML Type B flat 3 × 1.56.36.712.913.51406824290.21
TML Type B flat 3 × 2.57.17.51515.619011332380.36
TML Type B flat 3 × 48917.318.327018043520.57
TML Type B flat 3 × 6910192036027056670.86
TML Type B flat 3 × 101112242557045078931.43
TML Type B flat 3 × 1611.712.728.329.37607201041252.29
TML Type B flat 3 × 2515.516.53738125011251381653.58
TML Type B flat 3 × 3515.517.537.539.5150015751712055.01
TML Type B flat 3 × 5018.520.545.547.5218022502132557.15
TML Type B flat 4G1.56.36.715.916.51709024290.21
TML Type B flat 4G2.56.87.218.719.324015032380.36
TML Type B flat 4G47.78.722.523.535024043520.57
TML Type B flat 4G68.59.524.525.545036056670.86
TML Type B flat 4G10101129.530.569060078931.43
TML Type B flat 4G1612.313.337.538.510409601041252.29
TML Type B flat 4G2513.715.343.545.1149015001381653.58
TML Type B flat 4G3515.517.547.549.5197021001712055.01
Standards

Standards

Technical references and test conditions for the specified construction.

Standards and test references
ItemReference
ConductorIEC 60228, Class 5
AC voltage test3 kV AC for 5 minutes
Construction / use referenceEN 50525-2-21 and the specified construction.
Core identificationDIN VDE 0293-308; numbered control cores where applicable.

For conductor classes and nominal metric cross-sections, see the IEC 60228 standard scope.

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.