OnGcekż-GW, O2nGcekż-G, O2nGcekż-GW & OnGcrekgż-G(S) (0.6/1–18/30 kV) Reinforced & Water-Blocked Mining Cable
OnGcekż-GW (OnGcekz-GW) is a 0.6/1 kV water-resistant screened mining trailing cable built to ZN-96/MP-13-K1172, with three EPR power cores under semi-conducting tape and tinned copper/fibre braid, a screened pilot group and rubber fillers on a bare earth conductor, in ten layouts from 3×25 to 3×120 mm²; the related O2nGcekż-G, O2nGcekż-GW and OnGcrekgż-G(S) up to 18/30 kV are engineered per order drawing.
Mobile machines in wet underground workings need trailing cable that keeps water out of the core while it is dragged and crushed, and higher-voltage machines need the same protection at medium voltage. This family groups the water-resistant OnGcekż-GW, also written OnGcekz-GW, with three related constructions: O2nGcekż-G with a double polychloroprene sheath, O2nGcekż-GW with a double sheath and water-blocking tape, and OnGcrekgż-G and OnGcrekgż-GS with an EP/CR sheath system.
The fully scheduled member is OnGcekż-GW at 0.6/1 kV to ZN-96/MP-13-K1172. Three tinned copper power cores with EPR insulation, each under a semi-conducting tape and a tinned copper/fibre braid with 30% coverage, are laid up with an insulated and screened pilot group and rubber fillers on a tinned copper earth conductor, wrapped in polyester tape and sheathed in polychloroprene that exceeds type ON-4. Ten layouts run from 3×25+16+3×2.5 to 3×120+50+6×4 mm², with outer diameters of 37.0 mm to 60.6 mm and current ratings of 152 A to 400 A.
The medium-voltage OnGcekż-GW and O2nGcekż-GW at 3.6/6 to 18/30 kV add water-blocking tape around the core, and OnGcrekgż-G(S) to ZN-95/MP-13-K104 is intended for fixed installation. These variants are engineered per order drawing and never borrow the 0.6/1 kV dimensions.
Explore the mining and tunneling cable range for related configurations.
OnGcekż-GW (OnGcekz-GW) Family Cable Construction & Water Blocking
The representative horizontal sample shows OnGcekż-GW 0.6/1 kV 3x70+35+3x4 mm²: three EPR-insulated tinned copper power cores with semi-conducting tape and tinned copper/fibre braid screens, a screened pilot group and rubber fillers on a tinned copper earth conductor, a polyester tape wrap and a black polychloroprene sheath.

| Component | Material and construction |
|---|---|
| Power Conductors | Flexible tinned copper to PN-EN 60228 (IEC 60228) Class 5, 25 mm² to 120 mm² in the 0.6/1 kV schedule. |
| EPR Insulation | Ethylene-propylene rubber type IEP to PN-89/E-29100, 1.5 mm to 2.2 mm at 0.6/1 kV, over a polyester separator tape. |
| Power Core Screen | Semi-conducting tape plus composite tinned copper/fibre braid, 30% coverage at 0.6/1 kV. |
| Pilot Group, Earth and Fillers | Insulated and screened annealed tinned copper pilots, rubber fillers and a flexible tinned copper earth conductor, wrapped in polyester tape. |
| Water-Blocking Tape (MV GW) | Water-blocking tape around the core on the 3.6/6 to 18/30 kV OnGcekż-GW and O2nGcekż-GW constructions. |
| Polychloroprene Sheath | Polychloroprene exceeding type ON-4, 5.0 mm to 6.4 mm at 0.6/1 kV; double sheath on O2n types; EP/CR sheath system on OnGcrekgż-G(S). |
OnGcekż-GW, O2nGcekż-GW and OnGcrekgż-G(S) Type Designation Breakdown
- O: flexible rubber-sheathed (oponowy) cable
- n / 2n: single or double polychloroprene sheath (O2n types are double-sheathed)
- G: mining (górniczy) duty
- ekż: screened cores, pilot cores and protective earth conductor
- GW: water-resistant construction; water-blocking tape on the 3.6/6 to 18/30 kV builds
- OnGcrekgż-G(S): medium-voltage fixed-installation construction to ZN-95/MP-13-K104 with EP/CR sheath system
OnGcekż-GW, O2nGcekż-G and OnGcrekgż-G(S) Mining Applications & Duty Scope
Select the member by voltage, water exposure, sheath build and whether the cable trails or is fixed.

- Mobile mining machines on 0.6/1 kV supplies in wet workings, using the scheduled OnGcekż-GW layouts.
- Medium-voltage mobile machines and substations at 3.6/6 to 18/30 kV where water-blocked OnGcekż-GW or O2nGcekż-GW is specified.
- Heavily abraded trailing routes where the double polychloroprene sheath of O2nGcekż-G or O2nGcekż-GW is preferred.
- Fixed medium-voltage mine installations specifying OnGcrekgż-G or OnGcrekgż-GS with an EP/CR sheath system.
OnGcekż-GW Family vs OnGcekż-G and O2nGcekż/w-G Selection Boundary
| Model | Voltage | Distinguishing feature | Best fit |
|---|---|---|---|
| OnGcekż-GW (this page) | 0.6/1 kV and 3.6/6 to 18/30 kV | Water-resistant; water-blocking tape at medium voltage | Wet workings with trailing machines |
| O2nGcekż-G and O2nGcekż-GW (this page) | 0.6/1 kV and 3.6/6 to 18/30 kV | Double polychloroprene sheath | Heavily abraded trailing routes |
| OnGcrekgż-G(S) (this page) | 3.6/6 to 18/30 kV | EP/CR sheath system, fixed installation | Fixed medium-voltage mine installations |
| OnGcekż-G | 0.6/1 and 3.6/6 kV | Standard screened trailing cable | General screened trailing duty |
| O2nGcekż/w-G(A) and O2nGcekż/w-G(W) | 1.9/3.3 kV and 3.6/6 kV | Double-screened, double-sheath | Medium-voltage trailing cable with double screens |
Medium-voltage members are engineered per order drawing; state voltage, conductor size, pilot arrangement and duty when requesting a quotation.
Related selection resources
- Mining and tunneling cable engineering solutions
- Medium voltage mining cable selection guide
- OnGcekż-G 0.6/1 and 3.6/6 kV Screened Mining Cable
- O2nGcekż/w-G(A) 1.9/3.3 kV Mining Trailing Cable
- O2nGcekż/w-G(W) 3.6/6 kV Double-Screened Mining Cable
OnGcekż-GW (OnGcekz-GW) and O2nGcekż-GW Frequently Asked Questions
What does GW mean in OnGcekż-GW?
GW marks the water-resistant construction. On the 3.6/6 to 18/30 kV builds the core is also wrapped in water-blocking tape.
What is the difference between OnGcekż-G and O2nGcekż-G?
The O2n types have a double polychloroprene sheath; OnGcekż types have a single sheath. The core arrangement follows the same ZN-96/MP-13-K1172 construction.
Are the medium-voltage versions available in the same sizes as the 0.6/1 kV table?
No. The 3.6/6 to 18/30 kV OnGcekż-GW, O2nGcekż-GW and OnGcrekgż-G(S) are engineered per order drawing and do not use the 0.6/1 kV dimensions.
What are the MOQ and lead time?
The minimum order quantity is 50 m and the manufacturing lead time is 7 to 45 working days, depending on construction and quantity.
OnGcekż-GW Dimensions, Current Rating & Variant Specifications
OnGcekż-GW Family Key Specifications
- Voltage: 0.6/1 kV schedule; 3.6/6 to 18/30 kV per order drawing
- Sizes (0.6/1 kV): 3x25+16+3x2.5 to 3x120+50+6x4 mm²
- Water blocking: Water-blocking tape on the medium-voltage GW constructions
- Sheath: Single or double polychloroprene; EP/CR system on OnGcrekgż-G(S)
- Supply: MOQ 50 m; 7 to 45 working days
| Parameter | Value |
|---|---|
| Construction references | ZN-96/MP-13-K1172 (OnGcekż-GW, O2nGcekż-G, O2nGcekż-GW); ZN-95/MP-13-K104 (OnGcrekgż-G(S)) |
| Rated voltages | OnGcekż-GW and O2nGcekż-G 0.6/1 kV; OnGcekż-GW, O2nGcekż-GW and OnGcrekgż-G(S) 3.6/6 to 18/30 kV |
| Scheduled sizes | OnGcekż-GW 0.6/1 kV: ten layouts, 3x25+16+3x2.5 to 3x120+50+6x4 mm² |
| Conductor temperature | 90 °C maximum; ambient -35 °C to +55 °C (0.6/1 kV schedule) |
| Minimum bending radius | 8 x overall diameter (0.6/1 kV schedule) |
| Commercial supply terms | Minimum order quantity 50 m; manufacturing lead time 7 to 45 working days; final values confirmed on the quotation drawing |
| Selection boundary vs OnGcekż-G and O2nGcekż/w-G | Choose this family for water-resistant GW, double-sheath O2n and EP/CR OnGcrekgż-G(S) builds; choose OnGcekż-G for standard screened trailing cable and the O2nGcekż/w-G pages for 1.9/3.3 kV and 3.6/6 kV double-screened cable. |
OnGcekż-GW 0.6/1 kV Reference Schedule
| Size (mm²) | Power and Pilot Core Insulation (mm) | Outer Jacket (mm) | Approx./Max. Overall Diameter (mm) | Approx. Weight (kg/km) | Current-Carrying Capacity (A) | Next step |
|---|---|---|---|---|---|---|
| OnGcekż-GW 3x25+16+3x2.5 | 1.5 | 5.0 | 37.0 | 2164 | 152 | Request this size |
| OnGcekż-GW 3x35+16+3x2.5 | 1.6 | 5.0 | 38.8 | 2500 | 187 | Request this size |
| OnGcekż-GW 3x35+16+6x2.5 | 1.6 | 5.0 | 40.3 | 2736 | 187 | Request this size |
| OnGcekż-GW 3x50+25+3x4 | 1.7 | 5.5 | 45.2 | 3503 | 233 | Request this size |
| OnGcekż-GW 3x50+25+6x2.5 | 1.7 | 5.5 | 45.2 | 3528 | 233 | Request this size |
| OnGcekż-GW 3x70+35+3x4 | 1.8 | 5.5 | 50.0 | 4580 | 288 | Request this size |
| OnGcekż-GW 3x70+35+6x2.5 | 1.8 | 5.5 | 50.0 | 4600 | 288 | Request this size |
| OnGcekż-GW 3x70+35+6x4 | 1.8 | 5.5 | 50.7 | 4655 | 288 | Request this size |
| OnGcekż-GW 3x95+35+6x4 | 2.0 | 6.4 | 58.0 | 5917 | 345 | Request this size |
| OnGcekż-GW 3x120+50+6x4 | 2.2 | 6.4 | 60.6 | 6947 | 400 | Request this size |
O2nGcekż-G, O2nGcekż-GW and OnGcrekgż-G(S) Variant Matrix
| Model | Voltage | Construction Reference | Core Arrangement | Water Blocking | Sheath | Duty | Dimension Basis |
|---|---|---|---|---|---|---|---|
| OnGcekż-GW | 0.6/1 kV | ZN-96/MP-13-K1172 | Screened power cores and screened pilot group on a bare earth core with rubber fillers | Water-resistant construction | Single polychloroprene | Trailing | Reference schedule in the table above |
| OnGcekż-GW | 3.6/6 to 18/30 kV | ZN-96/MP-13-K1172 | Screened power and pilot cores on a bare protective core with rubber fillers | Water-blocking tape | Single CR (polychloroprene) | Trailing | Engineered per order drawing |
| O2nGcekż-G | 0.6/1 kV | ZN-96/MP-13-K1172 | Screened power and pilot cores on a bare protective core with rubber fillers | Not specified | Double CR (polychloroprene) | Trailing | Engineered per order drawing |
| O2nGcekż-GW | 3.6/6 to 18/30 kV | ZN-96/MP-13-K1172 | Screened power and pilot cores on a bare protective core with rubber fillers | Water-blocking tape | Double CR (polychloroprene) | Trailing | Engineered per order drawing |
| OnGcrekgż-G | 3.6/6 to 18/30 kV | ZN-95/MP-13-K104 | Screened power and protective cores on a rubber-filled bare protective core, synthetic tape | Not specified | EP/CR sheath system | Fixed installation | Engineered per order drawing |
| OnGcrekgż-GS | 3.6/6 to 18/30 kV | ZN-95/MP-13-K104 | As OnGcrekgż-G; the S execution detail is fixed on the order drawing | Not specified | EP/CR sheath system | Fixed installation | Engineered per order drawing |
Only the OnGcekż-GW 0.6/1 kV layouts are scheduled; O2nGcekż-G, the medium-voltage OnGcekż-GW and O2nGcekż-GW and OnGcrekgż-G(S) are engineered per order drawing and never take the 0.6/1 kV dimensions.
Polish designations and the ZN / WT works standards are cited as construction references; TEBAOFLEX builds to the referenced construction and does not claim a Polish mining admission or third-party approval for it, so state the approval documents your mine requires when requesting a quotation.
ASCII part references for BOM and ERP entry: OnGcekz-GW 3x25+16+3x2.5, OnGcekz-GW 3x35+16+3x2.5, OnGcekz-GW 3x35+16+6x2.5, OnGcekz-GW 3x50+25+3x4, OnGcekz-GW 3x50+25+6x2.5, OnGcekz-GW 3x70+35+3x4, OnGcekz-GW 3x70+35+6x2.5, OnGcekz-GW 3x70+35+6x4, OnGcekz-GW 3x95+35+6x4, OnGcekz-GW 3x120+50+6x4.
OnGcekż-GW Family Standards & Test References (ZN-96/MP-13-K1172, ZN-95/MP-13-K104)
| Standard or specification | Application |
|---|---|
| ZN-96/MP-13-K1172 | Works construction reference for OnGcekż-GW, O2nGcekż-G and O2nGcekż-GW mining cables. |
| ZN-95/MP-13-K104 | Works construction reference for OnGcrekgż-G and OnGcrekgż-GS medium-voltage mining cables. |
| PN-EN 60228 / IEC 60228 | Conductors of insulated cables: Class 5 flexible tinned copper conductors and maximum DC resistance. |
| PN-89/E-29100 | Polish compound specification for EPR insulation type IEP and polychloroprene sheath types. |
Certifications and document support
TEBAOFLEX company certificates and quality system documentation
IEC Webstore — IEC 60228 conductor class and resistance publication (international references)
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
OnGcekż-G 0.6/1 & 3.6/6 kV Screened Mining Cable
A related cable option for a different application or duty profile.
View productO2nGcekż/w-G(A) 1.9/3.3 kV Mining Trailing Cable
A related cable option for a different application or duty profile.
View productO2nGcekż/w-G(W) 3.6/6 kV Double-Screened Mining Cable
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.