FEP/FEP 600 V (UL 20710) & ETFE (UL 20221) Multi-Conductor Control Cable
FEP/FEP 600 V (including thin-wall UL 20710, -70 °C to +200 °C) and ETFE multi-conductor control cables (UL 20221 300 V / UL 20222 600 V, -70 °C to +150 °C) combine stranded tinned or silver-plated copper conductors (22 AWG to 10 AWG, 2 to 12 cores) with torque-free binder wraps, optional foil/braid shields and extruded fluoropolymer jackets.
FEP/FEP 600 V (engineered to heavy industrial 600 V and thin-wall UL 20710 geometries) and ETFE multi-conductor control cables (engineered to UL 20221 300 V and UL 20222 600 V) provide compact, fluid-impervious North American AWG multi-core power and instrumentation wiring from 22 AWG to 10 AWG (with 8 AWG to 2 AWG power feeders available to order).
Around steelworks continuous casters, glass furnace lehrs, boiler steam-header actuators, chemical batch reactors and semiconductor cleanroom tools, conventional EPR/CPE or PVC tray cables harden under +200 °C radiant heat or degrade in chlorinated solvents and acid mist. Torque-free cabled FEP/FEP conductors wrapped in high-temperature aramid binder tape pull smoothly through rigid metal conduit without memory kinking while maintaining a 30 % smaller outer diameter than thermoset rubber cables.
Select 200 °C 600 V FEP/FEP (or dual foil-and-braid shielded FEP/FEP for noisy VFD and instrumentation runs) up to +200 °C, or specify 150 °C UL 20221 / UL 20222 ETFE multi-conductor cable where severe mechanical crush, drag abrasion or up to 10 Mrad radiation dominates (MOQ 300 m / 305 m reel, 7 to 45 working days).
Explore the high-temperature wire and cable range for related configurations.
FEP/FEP 600 V & ETFE (UL 20221) Cable Construction
Built with torque-balanced concentric cabling, ICEA K-2 colour-coded fluoropolymer primaries and industrial-grade EMI shielding options.

| Component | Material and construction |
|---|---|
| 1. Stranded Plated Copper Conductors (22 AWG to 10 AWG) | Annealed tinned copper (7-strand or 19-strand per ASTM B33) as standard up to +180/+200 °C; silver-plated or nickel-plated copper available for continuous +200 °C or corrosive terminations. |
| 2. Extruded FEP or ETFE Primary Insulation (ICEA K-2 Colours) | Colour-coded fluorinated ethylene propylene (0.41 mm / 16 mil nominal wall) or tough ethylene-tetrafluoroethylene primaries (black, white, red, green, orange, blue). |
| 3. Torque-Free Aramid Binder & Optional Foil / Braid Shield | High-temperature aramid binder tape eliminates lay memory; optional 100 % aluminium/polyimide-aramid tape with drain wire or 100 % foil + 85 % tinned copper braid. |
| 4. Extruded FEP or ETFE Industrial Outer Jacket | Smooth low-friction black, red or white FEP (-70 °C to +200 °C) or ETFE (-70 °C to +150 °C) outer sheath resisting steam, acids, oils and UV. |
FEP/FEP, UL 20710 & UL 20221/20222 Code Breakdown
- FEP/FEP: Extruded fluorinated ethylene propylene primary insulation and outer jacket (-70 °C to +200 °C)
- UL 20710: 600 V AC, +200 °C thin-wall multi-conductor FEP equipment control cable specification
- UL 20221 / 20222: 300 V AC (20221) and 600 V AC (20222), +150 °C tough ETFE multi-conductor control cable
- K-2 Colour Code: ICEA Method 1 Table K-2 core identification (black, white, red, green, orange, blue)
- Foil + TC Braid: Optional 100 % Al/aramid tape + 85 % tinned copper braid EMI/RFI shield
FEP/FEP & ETFE Boiler, Steel, Cleanroom & Chemical Duties
Designed for industrial conduits, cable trays, boiler skids, semiconductor fabs and automated machinery.

- Boiler soot-blower controls, steam turbine valve actuators, power-plant damper drives and high-ambient conduit runs up to +200 °C.
- Steel mill hot-strip tables, glass container forming machines, aluminum homogenizing furnaces and petrochemical analyzer shelters.
- Semiconductor wet-bench exhaust controls and cleanroom equipment skids requiring low-outgassing dual-shielded FEP/FEP cables.
- High-vibration automated assembly lines, chemical dosing pumps and radiation-exposed valve islands using tough UL 20221 / 20222 ETFE jackets.
FEP/FEP (UL 20710) vs ETFE (UL 20221) vs Silicone vs Mica
| AWG Multi-Core Family | Temp. & Voltage | Mechanical & Fluid Profile | Primary Industrial Application |
|---|---|---|---|
| FEP/FEP 600 V & UL 20710 (this page) | -70 °C to +200 °C | 600 V | Total acid/solvent/steam immunity, compact conduit OD | Boilers, steel/glass plants, cleanrooms & chemical valve skids |
| ETFE/ETFE UL 20221 / 20222 (this page) | -70 °C to +150 °C | 300/600 V | Highest cut-through, crush & 10 Mrad radiation toughness | Automated machinery, robotics, nuclear & oil-splash control harnesses |
| SRG-K Silicone-Aramid (ID 4808) | -60 °C to +200 °C | 600 V | Extra-flexible elastomer core + aramid braid (dry heat) | Flexible hot-zone pendants & furnaces without acid/solvent immersion |
| Multicore Mica-Glass (ID 4807) | Up to +450 °C | 600 V | Inorganic mica + glass braid for extreme dry radiant heat | Kiln burner zones & molten-metal proximity above +260 °C |
Specify FEP/FEP up to +200 °C in wet/chemical conduits; step up to PFA/PFA (+260 °C) or Multicore Mica (+450 °C) for hotter zones.
FEP/FEP & ETFE Multi-Conductor Cable RFQ Checklist
- Jacket & primary polymer system: 200 °C 600 V FEP/FEP (heavy industrial or thin-wall UL 20710) or 150 °C ETFE/ETFE (UL 20221 / 20222).
- Conductor count (2/C to 12/C) and AWG size (22 AWG to 10 AWG, or custom 8–2 AWG power feeders).
- Shielding configuration: unshielded, 100 % Al/aramid foil + drain wire, or 100 % foil + 85 % tinned copper braid.
- Outer jacket colour (black, red or white) and reel footage (MOQ 305 m / 1,000 ft or 300 m, 7 to 45 working days).
Related selection resources
- Browse all High-Temperature Fluoropolymer, Silicone & Mica Cables
- Compare FFCT & FFCT-SB 600 V 200 °C Fluoroplastic Equipment Cable
- Compare SRG-K 200 °C 600 V Silicone-Aramid Multicore Cable
- Upgrade to 450 °C 600 V Multicore Mica-Glass High-Temp Cable
- Engineering guide: Comparing FEP, ETFE, PFA, silicone and mica
FEP/FEP 600 V & UL 20710 / UL 20221 Control Cable FAQ
What is the difference between FEP/FEP (UL 20710) and ETFE/ETFE (UL 20221 / 20222) control cables?
50 °C of thermal margin versus mechanical crush strength: FEP/FEP operates continuously up to +200 °C with superior chemical and low-smoke performance, whereas ETFE/ETFE is rated to +150 °C (`300 V` on UL 20221, `600 V` on UL 20222) and provides 2x–3x higher abrasion, pinch and radiation resistance.
Can shielded FEP/FEP multi-conductor cable be used as an NEC CMP building plenum cable?
No — although dual-shielded FEP/FEP uses low-smoke fluoropolymer insulation and jacketing, TEBAOFLEX supplies it strictly as an industrial OEM, cleanroom-equipment and conduit control cable without NEC CMP / NFPA 262 building fire-marshal listing.
Why does FEP/FEP 600 V cable use an internal high-temperature aramid binder tape?
0 lay-memory kinking during conduit pulls: the torque-free aramid binder isolates the FEP primaries from hot outer-jacket extrusion Adhesion so the cable strips cleanly and pulls smoothly around 90-degree conduit bends.
What shielding option is best for 4–20 mA transmitters and VFD drives on FEP/FEP cables?
100 % aluminium-laminate foil tape plus an 85 % tinned copper braid shield provides both high-frequency RF reflection and low-impedance 50/60 Hz ground drainage.
What is the minimum order quantity and lead time for FEP/FEP and UL 20221 ETFE cables?
305 m (1,000 ft) or 300 m minimum order per configuration on export reels, manufactured in 7 to 45 working days.
FEP/FEP 600 V, UL 20710 & UL 20221/20222 Schedules
FEP/FEP & ETFE Key Voltage, Shielding & Reel Summary
- North American AWG tray & conduit sizing: 18 AWG to 10 AWG heavy-duty 600 V FEP/FEP schedules (4.72 to 12.62 mm OD) plus compact 22–16 AWG UL 20710 & UL 20221/20222 OEM harnesses
- FEP (200 °C) or ETFE (150 °C) jackets: Choose chemical-immune 200 °C FEP/FEP for boilers, glass/steel plants and cleanrooms, or cut-through-tough 150 °C ETFE/ETFE for high-abrasion automation
- Unshielded or 100% foil + 85% braid: Available unshielded with high-temp aramid binder tape, with 100 % Al/aramid tape shield, or dual 100 % foil + 85 % tinned copper braid shield
- Low-smoke flame-retardant fluoropolymer: Inherent low-smoke, self-extinguishing VW-1 / FT1 fluoropolymer jacket suitable for industrial raceways, conduits, cleanrooms and equipment skids
- 300 m / 305 m factory reel put-up: Supplied in 305 m (1,000 ft) or 300 m continuous melt-extruded reels with a 7 to 45 working days factory lead time
| Parameter | Value |
|---|---|
| Rated voltage | 600 V AC on heavy FEP/FEP, UL 20710 FEP and UL 20222 ETFE constructions; 300 V AC on thin-wall UL 20221 ETFE and compact dual-shielded instrumentation builds |
| Conductor and core range | 2 to 12 conductors from 22 AWG to 10 AWG (7-strand or 19-strand tinned or silver-plated copper), with 8 AWG to 2 AWG feeders available on request |
| Insulation, shield and jacket | Extruded FEP/FEP (-70 C to +200 C) or ETFE/ETFE (-70 C to +150 C), unshielded with aramid binder or shielded with 100% foil + 85% tinned copper braid |
| Minimum bending radius and capacitance | 8x to 10x OD minimum bend radius; shielded 14 AWG 4/C reference capacitance approx. 98 pF/m conductor-to-conductor and 170 pF/m conductor-to-shield |
| Standard put-up and lead time | 305 m (1000 ft) or 300 m minimum order factory reels delivered in 7 to 45 working days |
| Standards compliance note | Engineered to UL 758 AWM Styles 20710, 20221 and 20222 industrial equipment cable criteria (third-party UL/CSA or NEC CMP building-plenum listing is not claimed) |
| Fluid, steam and flame behaviour | Self-extinguishing VW-1 / FT1 fluoropolymer jacket immune to steam condensate, hydraulic oils, acids, bases and chlorinated solvents |
FEP/FEP 600 V (200 °C) Multi-Conductor Control Cable Schedule
| Model & AWG Configuration | Stranding | Unshielded OD (in / mm) | Foil+Braid Shielded OD (mm) | Unshielded Weight (lbs/kft / kg/km) | Max. Pull Tension (N) | Standard Reel MOQ | Next step |
|---|---|---|---|---|---|---|---|
| FEP/FEP 600V 2/C 18 AWG | 7/26 TC | 0.186 / 4.72 | 5.45 | 26.0 / 38.8 | 290 | 305 m / 300 m | Request this size |
| FEP/FEP 600V 3/C 18 AWG | 7/26 TC | 0.198 / 5.03 | 5.78 | 34.9 / 52.0 | 435 | 305 m / 300 m | Request this size |
| FEP/FEP 600V 4/C 18 AWG | 7/26 TC | 0.217 / 5.51 | 6.30 | 41.8 / 62.2 | 580 | 305 m / 300 m | Request this size |
| FEP/FEP 600V 6/C 18 AWG | 7/26 TC | 0.264 / 6.71 | 7.55 | 60.5 / 90.1 | 870 | 305 m / 300 m | Request this size |
| FEP/FEP 600V 2/C 16 AWG | 7/24 TC | 0.211 / 5.36 | 6.15 | 34.6 / 51.4 | 460 | 305 m / 300 m | Request this size |
| FEP/FEP 600V 3/C 16 AWG | 7/24 TC | 0.225 / 5.72 | 6.55 | 47.3 / 70.4 | 690 | 305 m / 300 m | Request this size |
| FEP/FEP 600V 4/C 16 AWG | 7/24 TC | 0.247 / 6.27 | 7.10 | 58.1 / 86.4 | 920 | 305 m / 300 m | Request this size |
| FEP/FEP 600V 6/C 16 AWG | 7/24 TC | 0.307 / 7.80 | 8.65 | 89.6 / 133.4 | 1,380 | 305 m / 300 m | Request this size |
| FEP/FEP 600V 2/C 14 AWG | 7/22 TC | 0.242 / 6.15 | 6.95 | 48.6 / 72.3 | 600 | 305 m / 300 m | Request this size |
| FEP/FEP 600V 3/C 14 AWG | 7/22 TC | 0.257 / 6.53 | 7.35 | 66.1 / 98.3 | 900 | 305 m / 300 m | Request this size |
| FEP/FEP 600V 4/C 14 AWG | 7/22 TC | 0.289 / 7.34 | 7.90 | 85.3 / 127.0 | 1,200 | 305 m / 300 m | Request this size |
| FEP/FEP 600V 6/C 14 AWG | 7/22 TC | 0.352 / 8.94 | 9.80 | 126.8 / 188.7 | 1,800 | 305 m / 300 m | Request this size |
| FEP/FEP 600V 3/C 12 AWG | 19/25 TC | 0.301 / 7.65 | 8.55 | 96.8 / 144.0 | 1,420 | 305 m / 300 m | Request this size |
| FEP/FEP 600V 4/C 12 AWG | 19/25 TC | 0.331 / 8.41 | 9.30 | 122.8 / 182.8 | 1,900 | 305 m / 300 m | Request this size |
| FEP/FEP 600V 3/C 10 AWG | 19/22 TC | 0.360 / 9.14 | 10.10 | 145.5 / 216.5 | 2,250 | 305 m / 300 m | Request this size |
| FEP/FEP 600V 4/C 10 AWG | 19/22 TC | 0.397 / 10.08 | 11.05 | 185.5 / 276.1 | 3,000 | 305 m / 300 m | Request this size |
UL 20710 (200 °C FEP) & UL 20221 / 20222 (150 °C ETFE) Thin-Wall Schedule
| Style & Configuration | Polymer & Rating | Stranding | Nom. Jacket Wall (mm) | Nom. Outer Ø (mm) | Approx. Weight (kg/km) | Standard Reel MOQ | Next step |
|---|---|---|---|---|---|---|---|
| UL 20710 4/C 22 AWG | FEP/FEP 200 °C 600 V | 7/30 SPC | 0.40 | 4.10 | 29 | 305 m / 300 m | Request this size |
| UL 20710 4/C 20 AWG | FEP/FEP 200 °C 600 V | 7/28 SPC | 0.40 | 4.65 | 39 | 305 m / 300 m | Request this size |
| UL 20710 8/C 20 AWG | FEP/FEP 200 °C 600 V | 7/28 SPC | 0.45 | 6.20 | 74 | 305 m / 300 m | Request this size |
| UL 20221 4/C 22 AWG | ETFE/ETFE 150 °C 300 V | 19/34 TPC | 0.38 | 3.85 | 25 | 305 m / 300 m | Request this size |
| UL 20221 7/C 20 AWG | ETFE/ETFE 150 °C 300 V | 19/32 TPC | 0.42 | 5.35 | 58 | 305 m / 300 m | Request this size |
| UL 20222 4/C 18 AWG | ETFE/ETFE 150 °C 600 V | 19/30 TPC | 0.50 | 5.30 | 56 | 305 m / 300 m | Request this size |
| UL 20222 4/C 16 AWG | ETFE/ETFE 150 °C 600 V | 19/29 TPC | 0.55 | 6.05 | 79 | 305 m / 300 m | Request this size |
ASCII part references for BOM and ERP entry: TF-FEP600-4C18AWG, TF-FEP600-4C16AWG, TF-FEP600-4C14AWG, TF-FEP600-4C14AWG-SH, TF-FEP600-4C12AWG, TF-UL20710-4C20AWG, TF-UL20221-4C22AWG, TF-UL20222-4C16AWG.
Important building-code boundary: while dual-shielded FEP/FEP uses the same low-smoke fluoropolymer chemistry as North American air-handling cables, TEBAOFLEX supplies these cables strictly for industrial machinery, cleanroom tools and OEM equipment (NEC Article 800/760 CMP/FPLP fire-marshal listing is not claimed).
FEP/FEP & ETFE UL 758, ICEA K-2 & ASTM Reference Standards
| Standard or specification | Application |
|---|---|
| UL 758 (Engineered to AWM Styles 20710, 20221 & 20222) | Thin-wall and standard-wall multi-conductor FEP (200 °C, 600 V) and ETFE (150 °C, 300/600 V) equipment cable dimensions and VW-1 / FT1 flame tests (third-party UL/CSA mark is not claimed). |
| ICEA S-73-532 / NEMA WC 57 Method 1 (Table K-2) | North American multi-conductor industrial control colour-coding convention. |
| ASTM B33 & ASTM B298 | Stranded annealed tinned copper and silver-plated copper conductor specifications. |
Certifications and document support
TEBAOFLEX ISO 9001 quality management and factory HV spark/dielectric testing
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
FFCT Fluoroplastic Cable 600 V 200°C
A related cable option for a different application or duty profile.
View productSRG-K Multicore Silicone-Aramid Braided Cable, 200°C 600 V
A related cable option for a different application or duty profile.
View productMulticore Mica-Glass High-Temperature Cable, 450°C 600 V
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.