FEP/FEP 600 V (including thin-wall UL 20710, -70 °C to +200 °C) and ETFE multi-conductor control cables (UL 20221 300 V / UL 20222 600 V, -70 °C to +150 °C) combine stranded tinned or silver-plated copper conductors (22 AWG to 10 AWG, 2 to 12 cores) with torque-free binder wraps, optional foil/braid shields and extruded fluoropolymer jackets.

Product information
SKU
TF-FEP-ETFE-600V-MC
Brand
TEBAOFLEX
Product overview

FEP/FEP 600 V (engineered to heavy industrial 600 V and thin-wall UL 20710 geometries) and ETFE multi-conductor control cables (engineered to UL 20221 300 V and UL 20222 600 V) provide compact, fluid-impervious North American AWG multi-core power and instrumentation wiring from 22 AWG to 10 AWG (with 8 AWG to 2 AWG power feeders available to order).

Around steelworks continuous casters, glass furnace lehrs, boiler steam-header actuators, chemical batch reactors and semiconductor cleanroom tools, conventional EPR/CPE or PVC tray cables harden under +200 °C radiant heat or degrade in chlorinated solvents and acid mist. Torque-free cabled FEP/FEP conductors wrapped in high-temperature aramid binder tape pull smoothly through rigid metal conduit without memory kinking while maintaining a 30 % smaller outer diameter than thermoset rubber cables.

Select 200 °C 600 V FEP/FEP (or dual foil-and-braid shielded FEP/FEP for noisy VFD and instrumentation runs) up to +200 °C, or specify 150 °C UL 20221 / UL 20222 ETFE multi-conductor cable where severe mechanical crush, drag abrasion or up to 10 Mrad radiation dominates (MOQ 300 m / 305 m reel, 7 to 45 working days).

Explore the high-temperature wire and cable range for related configurations.

Construction

FEP/FEP 600 V & ETFE (UL 20221) Cable Construction

Built with torque-balanced concentric cabling, ICEA K-2 colour-coded fluoropolymer primaries and industrial-grade EMI shielding options.

Clean 2D engineering cross-section of 600 V FEP/FEP 4/C 14 AWG cable showing black FEP outer jacket, off-white binder wrap and four 7-strand tinned copper FEP conductors
FEP/FEP 4/C 14 AWG cross-section: extruded FEP sheath, binder tape and four 7x22 tinned copper conductors.
FEP/FEP 600 V (UL 20710) & ETFE (UL 20221) Multi-Conductor Control Cable construction
ComponentMaterial and construction
1. Stranded Plated Copper Conductors (22 AWG to 10 AWG)Annealed tinned copper (7-strand or 19-strand per ASTM B33) as standard up to +180/+200 °C; silver-plated or nickel-plated copper available for continuous +200 °C or corrosive terminations.
2. Extruded FEP or ETFE Primary Insulation (ICEA K-2 Colours)Colour-coded fluorinated ethylene propylene (0.41 mm / 16 mil nominal wall) or tough ethylene-tetrafluoroethylene primaries (black, white, red, green, orange, blue).
3. Torque-Free Aramid Binder & Optional Foil / Braid ShieldHigh-temperature aramid binder tape eliminates lay memory; optional 100 % aluminium/polyimide-aramid tape with drain wire or 100 % foil + 85 % tinned copper braid.
4. Extruded FEP or ETFE Industrial Outer JacketSmooth low-friction black, red or white FEP (-70 °C to +200 °C) or ETFE (-70 °C to +150 °C) outer sheath resisting steam, acids, oils and UV.

FEP/FEP, UL 20710 & UL 20221/20222 Code Breakdown

  • FEP/FEP: Extruded fluorinated ethylene propylene primary insulation and outer jacket (-70 °C to +200 °C)
  • UL 20710: 600 V AC, +200 °C thin-wall multi-conductor FEP equipment control cable specification
  • UL 20221 / 20222: 300 V AC (20221) and 600 V AC (20222), +150 °C tough ETFE multi-conductor control cable
  • K-2 Colour Code: ICEA Method 1 Table K-2 core identification (black, white, red, green, orange, blue)
  • Foil + TC Braid: Optional 100 % Al/aramid tape + 85 % tinned copper braid EMI/RFI shield
Applications

FEP/FEP & ETFE Boiler, Steel, Cleanroom & Chemical Duties

Designed for industrial conduits, cable trays, boiler skids, semiconductor fabs and automated machinery.

Black 600 V FEP/FEP multi-conductor high-temperature control cables routed through stainless conduits onto motorized steam-valve actuators in a chemical processing plant
High-temperature steam-line valve actuators wired with solvent- and steam-proof 600 V FEP/FEP control cable.
  • Boiler soot-blower controls, steam turbine valve actuators, power-plant damper drives and high-ambient conduit runs up to +200 °C.
  • Steel mill hot-strip tables, glass container forming machines, aluminum homogenizing furnaces and petrochemical analyzer shelters.
  • Semiconductor wet-bench exhaust controls and cleanroom equipment skids requiring low-outgassing dual-shielded FEP/FEP cables.
  • High-vibration automated assembly lines, chemical dosing pumps and radiation-exposed valve islands using tough UL 20221 / 20222 ETFE jackets.

FEP/FEP (UL 20710) vs ETFE (UL 20221) vs Silicone vs Mica

FEP/FEP 600 V (UL 20710) vs ETFE/ETFE (UL 20221/20222) vs SRG-K Braided Silicone vs Mica Multicore
AWG Multi-Core FamilyTemp. & VoltageMechanical & Fluid ProfilePrimary Industrial Application
FEP/FEP 600 V & UL 20710 (this page)-70 °C to +200 °C | 600 VTotal acid/solvent/steam immunity, compact conduit ODBoilers, steel/glass plants, cleanrooms & chemical valve skids
ETFE/ETFE UL 20221 / 20222 (this page)-70 °C to +150 °C | 300/600 VHighest cut-through, crush & 10 Mrad radiation toughnessAutomated machinery, robotics, nuclear & oil-splash control harnesses
SRG-K Silicone-Aramid (ID 4808)-60 °C to +200 °C | 600 VExtra-flexible elastomer core + aramid braid (dry heat)Flexible hot-zone pendants & furnaces without acid/solvent immersion
Multicore Mica-Glass (ID 4807)Up to +450 °C | 600 VInorganic mica + glass braid for extreme dry radiant heatKiln burner zones & molten-metal proximity above +260 °C

Specify FEP/FEP up to +200 °C in wet/chemical conduits; step up to PFA/PFA (+260 °C) or Multicore Mica (+450 °C) for hotter zones.

FEP/FEP & ETFE Multi-Conductor Cable RFQ Checklist

  • Jacket & primary polymer system: 200 °C 600 V FEP/FEP (heavy industrial or thin-wall UL 20710) or 150 °C ETFE/ETFE (UL 20221 / 20222).
  • Conductor count (2/C to 12/C) and AWG size (22 AWG to 10 AWG, or custom 8–2 AWG power feeders).
  • Shielding configuration: unshielded, 100 % Al/aramid foil + drain wire, or 100 % foil + 85 % tinned copper braid.
  • Outer jacket colour (black, red or white) and reel footage (MOQ 305 m / 1,000 ft or 300 m, 7 to 45 working days).

Related selection resources

FEP/FEP 600 V & UL 20710 / UL 20221 Control Cable FAQ

What is the difference between FEP/FEP (UL 20710) and ETFE/ETFE (UL 20221 / 20222) control cables?

50 °C of thermal margin versus mechanical crush strength: FEP/FEP operates continuously up to +200 °C with superior chemical and low-smoke performance, whereas ETFE/ETFE is rated to +150 °C (`300 V` on UL 20221, `600 V` on UL 20222) and provides 2x–3x higher abrasion, pinch and radiation resistance.

Can shielded FEP/FEP multi-conductor cable be used as an NEC CMP building plenum cable?

No — although dual-shielded FEP/FEP uses low-smoke fluoropolymer insulation and jacketing, TEBAOFLEX supplies it strictly as an industrial OEM, cleanroom-equipment and conduit control cable without NEC CMP / NFPA 262 building fire-marshal listing.

Why does FEP/FEP 600 V cable use an internal high-temperature aramid binder tape?

0 lay-memory kinking during conduit pulls: the torque-free aramid binder isolates the FEP primaries from hot outer-jacket extrusion Adhesion so the cable strips cleanly and pulls smoothly around 90-degree conduit bends.

What shielding option is best for 4–20 mA transmitters and VFD drives on FEP/FEP cables?

100 % aluminium-laminate foil tape plus an 85 % tinned copper braid shield provides both high-frequency RF reflection and low-impedance 50/60 Hz ground drainage.

What is the minimum order quantity and lead time for FEP/FEP and UL 20221 ETFE cables?

305 m (1,000 ft) or 300 m minimum order per configuration on export reels, manufactured in 7 to 45 working days.

Specifications

FEP/FEP 600 V, UL 20710 & UL 20221/20222 Schedules

FEP/FEP & ETFE Key Voltage, Shielding & Reel Summary

  • North American AWG tray & conduit sizing: 18 AWG to 10 AWG heavy-duty 600 V FEP/FEP schedules (4.72 to 12.62 mm OD) plus compact 22–16 AWG UL 20710 & UL 20221/20222 OEM harnesses
  • FEP (200 °C) or ETFE (150 °C) jackets: Choose chemical-immune 200 °C FEP/FEP for boilers, glass/steel plants and cleanrooms, or cut-through-tough 150 °C ETFE/ETFE for high-abrasion automation
  • Unshielded or 100% foil + 85% braid: Available unshielded with high-temp aramid binder tape, with 100 % Al/aramid tape shield, or dual 100 % foil + 85 % tinned copper braid shield
  • Low-smoke flame-retardant fluoropolymer: Inherent low-smoke, self-extinguishing VW-1 / FT1 fluoropolymer jacket suitable for industrial raceways, conduits, cleanrooms and equipment skids
  • 300 m / 305 m factory reel put-up: Supplied in 305 m (1,000 ft) or 300 m continuous melt-extruded reels with a 7 to 45 working days factory lead time
FEP/FEP 600 V (UL 20710) & ETFE (UL 20221) Multi-Conductor Control Cable technical data
ParameterValue
Rated voltage600 V AC on heavy FEP/FEP, UL 20710 FEP and UL 20222 ETFE constructions; 300 V AC on thin-wall UL 20221 ETFE and compact dual-shielded instrumentation builds
Conductor and core range2 to 12 conductors from 22 AWG to 10 AWG (7-strand or 19-strand tinned or silver-plated copper), with 8 AWG to 2 AWG feeders available on request
Insulation, shield and jacketExtruded FEP/FEP (-70 C to +200 C) or ETFE/ETFE (-70 C to +150 C), unshielded with aramid binder or shielded with 100% foil + 85% tinned copper braid
Minimum bending radius and capacitance8x to 10x OD minimum bend radius; shielded 14 AWG 4/C reference capacitance approx. 98 pF/m conductor-to-conductor and 170 pF/m conductor-to-shield
Standard put-up and lead time305 m (1000 ft) or 300 m minimum order factory reels delivered in 7 to 45 working days
Standards compliance noteEngineered to UL 758 AWM Styles 20710, 20221 and 20222 industrial equipment cable criteria (third-party UL/CSA or NEC CMP building-plenum listing is not claimed)
Fluid, steam and flame behaviourSelf-extinguishing VW-1 / FT1 fluoropolymer jacket immune to steam condensate, hydraulic oils, acids, bases and chlorinated solvents

FEP/FEP 600 V (200 °C) Multi-Conductor Control Cable Schedule

200 °C 600 V FEP/FEP Multi-Conductor Industrial Control Cable (18 AWG to 10 AWG) — Dimensional & Weight Schedule
Model & AWG ConfigurationStrandingUnshielded OD (in / mm)Foil+Braid Shielded OD (mm)Unshielded Weight (lbs/kft / kg/km)Max. Pull Tension (N)Standard Reel MOQNext step
FEP/FEP 600V 2/C 18 AWG7/26 TC0.186 / 4.725.4526.0 / 38.8290305 m / 300 mRequest this size
FEP/FEP 600V 3/C 18 AWG7/26 TC0.198 / 5.035.7834.9 / 52.0435305 m / 300 mRequest this size
FEP/FEP 600V 4/C 18 AWG7/26 TC0.217 / 5.516.3041.8 / 62.2580305 m / 300 mRequest this size
FEP/FEP 600V 6/C 18 AWG7/26 TC0.264 / 6.717.5560.5 / 90.1870305 m / 300 mRequest this size
FEP/FEP 600V 2/C 16 AWG7/24 TC0.211 / 5.366.1534.6 / 51.4460305 m / 300 mRequest this size
FEP/FEP 600V 3/C 16 AWG7/24 TC0.225 / 5.726.5547.3 / 70.4690305 m / 300 mRequest this size
FEP/FEP 600V 4/C 16 AWG7/24 TC0.247 / 6.277.1058.1 / 86.4920305 m / 300 mRequest this size
FEP/FEP 600V 6/C 16 AWG7/24 TC0.307 / 7.808.6589.6 / 133.41,380305 m / 300 mRequest this size
FEP/FEP 600V 2/C 14 AWG7/22 TC0.242 / 6.156.9548.6 / 72.3600305 m / 300 mRequest this size
FEP/FEP 600V 3/C 14 AWG7/22 TC0.257 / 6.537.3566.1 / 98.3900305 m / 300 mRequest this size
FEP/FEP 600V 4/C 14 AWG7/22 TC0.289 / 7.347.9085.3 / 127.01,200305 m / 300 mRequest this size
FEP/FEP 600V 6/C 14 AWG7/22 TC0.352 / 8.949.80126.8 / 188.71,800305 m / 300 mRequest this size
FEP/FEP 600V 3/C 12 AWG19/25 TC0.301 / 7.658.5596.8 / 144.01,420305 m / 300 mRequest this size
FEP/FEP 600V 4/C 12 AWG19/25 TC0.331 / 8.419.30122.8 / 182.81,900305 m / 300 mRequest this size
FEP/FEP 600V 3/C 10 AWG19/22 TC0.360 / 9.1410.10145.5 / 216.52,250305 m / 300 mRequest this size
FEP/FEP 600V 4/C 10 AWG19/22 TC0.397 / 10.0811.05185.5 / 276.13,000305 m / 300 mRequest this size

UL 20710 (200 °C FEP) & UL 20221 / 20222 (150 °C ETFE) Thin-Wall Schedule

Thin-Wall Multi-Conductor Schedules Engineered to UL 20710 (200 °C, 600 V FEP) & UL 20221 / UL 20222 (150 °C ETFE)
Style & ConfigurationPolymer & RatingStrandingNom. Jacket Wall (mm)Nom. Outer Ø (mm)Approx. Weight (kg/km)Standard Reel MOQNext step
UL 20710 4/C 22 AWGFEP/FEP 200 °C 600 V7/30 SPC0.404.1029305 m / 300 mRequest this size
UL 20710 4/C 20 AWGFEP/FEP 200 °C 600 V7/28 SPC0.404.6539305 m / 300 mRequest this size
UL 20710 8/C 20 AWGFEP/FEP 200 °C 600 V7/28 SPC0.456.2074305 m / 300 mRequest this size
UL 20221 4/C 22 AWGETFE/ETFE 150 °C 300 V19/34 TPC0.383.8525305 m / 300 mRequest this size
UL 20221 7/C 20 AWGETFE/ETFE 150 °C 300 V19/32 TPC0.425.3558305 m / 300 mRequest this size
UL 20222 4/C 18 AWGETFE/ETFE 150 °C 600 V19/30 TPC0.505.3056305 m / 300 mRequest this size
UL 20222 4/C 16 AWGETFE/ETFE 150 °C 600 V19/29 TPC0.556.0579305 m / 300 mRequest this size

ASCII part references for BOM and ERP entry: TF-FEP600-4C18AWG, TF-FEP600-4C16AWG, TF-FEP600-4C14AWG, TF-FEP600-4C14AWG-SH, TF-FEP600-4C12AWG, TF-UL20710-4C20AWG, TF-UL20221-4C22AWG, TF-UL20222-4C16AWG.

Important building-code boundary: while dual-shielded FEP/FEP uses the same low-smoke fluoropolymer chemistry as North American air-handling cables, TEBAOFLEX supplies these cables strictly for industrial machinery, cleanroom tools and OEM equipment (NEC Article 800/760 CMP/FPLP fire-marshal listing is not claimed).

Standards

FEP/FEP & ETFE UL 758, ICEA K-2 & ASTM Reference Standards

FEP/FEP 600 V (UL 20710) & ETFE (UL 20221) Multi-Conductor Control Cable standards and test references
Standard or specificationApplication
UL 758 (Engineered to AWM Styles 20710, 20221 & 20222)Thin-wall and standard-wall multi-conductor FEP (200 °C, 600 V) and ETFE (150 °C, 300/600 V) equipment cable dimensions and VW-1 / FT1 flame tests (third-party UL/CSA mark is not claimed).
ICEA S-73-532 / NEMA WC 57 Method 1 (Table K-2)North American multi-conductor industrial control colour-coding convention.
ASTM B33 & ASTM B298Stranded annealed tinned copper and silver-plated copper conductor specifications.

Certifications and document support

TEBAOFLEX ISO 9001 quality management and factory HV spark/dielectric testing

UL 758 — Standard for Appliance Wiring Material

IEC 60332-1-2 — Vertical flame propagation test

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.