Marine & Offshore Cables TEBAOFLEX

TF-MCR Magnetic Hull Crawling Robot Umbilical Cable — Ultralight Aramid/LCP Hydroblasting, NDT & Amphibious Crawler Tether (XM520–XM554)

TF-MCR (TF-MCR-CRAWLER) is an ultralight, high-tensile power-data-optical umbilical cable engineered for permanent-magnet ship hull crawling robots used in dry-dock 2,800 bar UHP hydroblasting, grit blasting, airless painting, weld NDT and amphibious splash-zone inspection. Replacing steel wire braid with high-modulus aramid or LCP yarn cuts vertical hanging cable weight by up to 65% across 10.0–26.4 mm diameters (112–740 kg/km).

Product information
SKU
TF-MCR-CRAWLER
Brand
TEBAOFLEX
Product overview

TF-MCR magnetic hull crawling robot umbilical cables integrate 500 V to 0.6/1 kV servo/vacuum-motor power (0.34 mm² to 4G16 mm²), shielded Cat 6 Ethernet, 75-ohm coax or single-mode/multimode optical fibers inside an ultralight 10.0–26.4 mm aramid/LCP-reinforced polyurethane sheath weighing just 112–740 kg/km in air.

For shipyard dry-dock hydroblasting, abrasive blasting, spray-painting and ultrasonic thickness (UT / PAUT / PEC) hull crawlers, umbilical dead weight is the #1 payload killer: when a crawler climbs 30–35 meters up a VLCC or container ship flare—or hangs upside-down under the flat bottom—every extra kilogram of hanging cable pulls directly against permanent-magnet wheel adhesion and wheel-motor torque. Conventional steel-wire-armoured marine cables weigh 1,200–2,800 kg/km and cause premature slip on wet painted steel. TF-MCR replaces metallic armour with high-modulus liquid-crystal-polymer (LCP) or aramid braid, preserving 3.2–35 kN tensile strength at one-third the weight while shielding encoder/Ethernet signals from VFD drive noise.

Choose TF-MCR 4G2.5 through 4G16 heavy shipyard crawler power-hybrid schedules for UHP hydroblasting and coating robots (run alongside an externally banded UHP water/paint hose for safe burst isolation), or specify compact TF-MCR cross-reference builds 13XM553, 14XM523, 6XM551, 18XM522, 4XM554 and 26XM520 for NDT and amphibious inspection crawlers. Supplied as bulk cable on reels from 50 m MOQ in 7 to 45 working days.

Explore the marine, offshore and shipboard cable range for related configurations.

Construction

TF-MCR Ultralight Magnetic Hull Crawler Cable Construction

Built around ultra-flexible Class 6 copper conductors, EMC-screened data/optical sub-units, longitudinal water-blocking and weight-saving synthetic fiber tensile braids.

Clean 2D circular engineering cross-section of TF-MCR lightweight magnetic hull crawler cable showing orange PUR outer sheath, cream synthetic tensile braid, tinned-copper braid screen, four insulated power cores, turquoise Cat 6 quad unit and yellow fiber tube
Cross-section: non-metallic tensile braid and thin-wall HDPE/XLPE insulation cut 30 m vertical hang weight by 65% versus steel armour.
TF-MCR Magnetic Hull Crawling Robot Umbilical Cable — Ultralight Aramid/LCP Hydroblasting, NDT & Amphibious Crawler Tether (XM520–XM554) construction
ComponentMaterial and construction
1. Extra-Flexible Servo Power & Control Conductors (500 V / 1,000 V)IEC 60228 Class 5/6 tinned or bare copper conductors (0.22 mm² / 24 AWG signal up to 4G16 mm² 0.6/1 kV drive power) with thin-wall HDPE or XLPE insulation for compact outer diameter.
2. Shielded Ethernet, Coax or Fiber Optic Telemetry Unit100-ohm foil-screened subsea Cat 6 (4×2×24 AWG), RS-485/CAN twisted pairs, 95% tinned-copper-braided 75-ohm coaxial video core, or PBT/stainless-steel tube SM+MM optical fibers.
3. EMC Screening & Amphibious Longitudinal Water-BlockingIndividual pair foil/drain screens plus optional 85% tinned-copper overall braid (as in 4XM554) for VFD drive immunity, filled with silicone water-blocking compound and swelling tapes.
4. Ultralight LCP or High-Modulus Aramid Strength BraidNon-metallic liquid-crystal-polymer (LCP) or aramid fiber braid engineered for 320 kg to 3,500 kg breaking load with zero metallic springback over deck sheaves.
5. Abrasion-, Grit- & Solvent-Resistant Matte PUR SheathHydrolysis- and UV-resistant flame-retardant polyurethane outer jacket (High-Visibility Orange, Yellow or Black) formulated against UHP water mist rebound, blasting grit and marine paint thinners.

TF-MCR Power-Hybrid & XM520–XM554 Code Breakdown

  • TF-MCR 4G<mm²>: Shipyard vertical crawler 0.6/1 kV shielded 4-core servo power umbilical (4G2.5 mm² through 4G16 mm²)
  • +Cat6 / +FO / +2TSP: Integrated 100-ohm subsea Cat 6 data unit, stainless/PBT optical fibers (SM/MM), and screened RS-485/encoder pairs
  • 13XM553 / 6XM551 / 4XM554: Compact LCP-braided 75-ohm video coax hybrid (10.0 mm), 16 AWG + STP (11.0 mm) and 1 kV 4×2.5 mm² shielded power (13.0 mm) builds
  • 14XM523 / 18XM522 / 26XM520: 1,000 V electro-optical FIMT/PBT hybrids (10.4–11.2 mm) and 18×22 AWG + subsea Cat 6 LAN crawler tether (14.2 mm)
  • -OR / -YL: High-visibility shipyard safety Orange (-OR) or Neon Yellow (-YL) hydrolysis- and solvent-resistant matte PUR outer jacket
Applications

TF-MCR Dry-Dock Hydroblasting, Coating, NDT & Splash-Zone Duty

Engineered for vertical and inverted steel-plate magnetic crawlers across shipyards, offshore FPSOs, wind-tower monopiles and splash-zone inspections.

Permanent-magnet wheeled hull crawling robot climbing 25 meters vertically up a ship hull in dry dock during hydroblasting and NDT inspection while trailing a lightweight orange TF-MCR umbilical cable
Dry-dock magnetic hull crawler climbing vertical steel plating with an ultralight TF-MCR servo-and-data umbilical paid out from deck.
  • Shipyard dry-dock 2,500–3,000 bar UHP water-jetting (hydroblasting) rust- and coating-removal magnetic hull crawlers.
  • Automated hull grit-blasting, vacuum-recovery and airless epoxy/antifouling spray-painting magnetic climbing robots.
  • Ultrasonic phased-array (PAUT), pulsed eddy-current (PEC), alternating current field measurement (ACFM) and laser-profilometry hull NDT crawlers.
  • Amphibious waterline-crossing magnetic crawlers inspecting FPSO hulls, offshore wind monopiles, sheet-pile quay walls and hydroelectric penstocks.

TF-MCR Crawler Cable vs Buoyant ROV Tether & Tank Crawler Cable

TF-MCR Magnetic Hull Crawler Umbilical vs TF-HULL Buoyant ROV Tether vs TF-TANKCRAWL COT Oil-Tank Umbilical vs Steel-Braided Crane Cable
Cable Series30 m Hang Weight (4G4 eq.)Jacket & Fluid EnvironmentTarget Robotic Platform
TF-MCR Crawler Cable (this page)~9.3 kg (Aramid / LCP braid)Cut-resistant PUR; dry dock + seawater amphibiousMagnetic hull hydroblasting, grit-blasting, painting & NDT robots
TF-HULL Biofouling TetherBuoyant foam (larger OD in air)Syntactic flotation + barnacle-cut PUR / LDPESubmerged thruster-driven hull-grooming & cavitation ROVs
TF-TANKCRAWL Antistatic Cable~10.5 kg (Aramid + antistatic sheath)Antistatic (<10^8 Ω) crude/naphtha/sludge-resistantVLCC cargo oil tank (COT), FPSO & refinery sludge crawlers
Standard GSWB Marine Cable~24–32 kg (Heavy steel braid)Fixed shipboard LSZH (excessive hang weight)Static shipboard wiring only (unsuitable for vertical crawlers)

Climbing inside crude-oil cargo tanks (COT) or petrochemical storage tanks instead of exterior ship hulls? Switch to TF-TANKCRAWL with an antistatic hydrocarbon-resistant outer sheath.

TF-MCR Magnetic Hull Crawler Umbilical RFQ Checklist

  • Maximum vertical climb height on hull (e.g., 25 m, 35 m, 45 m) and maximum allowable umbilical hanging weight budget (kg).
  • Drive power conductors (voltage in V AC or V DC, current in A, core count & size such as 4G2.5, 4G6 or 2×16 AWG) and VFD EMC shielding needs.
  • Signal & vision elements: subsea Cat 6 Ethernet, RS-485/CAN pairs, 75-ohm coax, or single-mode / multimode optical fibers.
  • Operating zone: dry-dock UHP hydroblasting / painting only, or amphibious waterline-crossing immersion requiring longitudinal water-blocking.
  • Continuous reel length(s) (bulk cable on wooden drums with heat-shrink end caps; MOQ 50 m, 7 to 45 working days).

Related selection resources

TF-MCR Magnetic Hull Crawling Robot Umbilical Cable FAQ

How much vertical hanging weight does TF-MCR save on a 30-meter ship hull climb compared with steel-armoured marine cable?

60% to 68% weight reduction: a 30 m vertical drop of TF-MCR 4G4+Cat6+2TSP weighs only 9.3 kg in air versus 25–30 kg for galvanized steel-wire-braided cable, preserving magnetic wheel breakaway safety margin on wet or Thick-film painted hull steel.

Why is the 2,800 bar UHP hydroblasting hose kept separate from the TF-MCR electrical umbilical?

2,500–3,000 bar water-jetting lances operate near extreme cyclic fatigue limits and require periodic hose replacement; running TF-MCR alongside the UHP hose inside a replaceable protective textile scuff sleeve prevents a high-pressure water pinhole from rupturing electrical and fiber cores.

Can TF-MCR magnetic crawler cables operate both in dry dock and underwater below the ship's waterline?

Yes — TF-MCR incorporates silicone water-blocking compound or super-absorbent swelling tapes plus hydrolysis-resistant polyether PUR sheathing, enabling amphibious hull crawlers to drive straight from sun-heated dry steel down to 50–300 m submerged hull plates.

Are 13XM553, 14XM523, 6XM551, 18XM522, 4XM554 and 26XM520 specifications available in the TF-MCR range?

Yes — all six compact LCP-braided power, 75-ohm video coax, subsea Cat 6 and stainless-tube FIMT optical configurations (Ø 10.0 mm to 14.2 mm, 112 to 230 kg/km) are manufactured as continuous bulk cable from 50 m MOQ.

How is TF-MCR delivered and what are the minimum order quantity and lead time?

50 m minimum order quantity per specification, supplied as continuous cut-to-length bulk cable on wooden drums with heat-shrink water-blocking end caps in 7 to 45 working days.

Specifications

TF-MCR (4G2.5–4G16 & XM520–XM554) Crawler Cable Schedule

TF-MCR Vertical Hang-Weight Budget, LCP Braid & 50 m MOQ

  • 65% lighter to stop de-magnetization: Aramid / LCP fiber braid delivers 3.2 kN to 35 kN breaking strength at 112–740 kg/km air weight—protecting magnetic wheel breakaway margin on 25–40 m vertical and inverted flat-bottom hull climbs
  • Dry-dock UHP jet & grit resistant: High-rebound cut-resistant polyether PUR jacket withstands 2,500–3,000 bar hydroblasting mist rebound, steel grit impact, hot deck plates and epoxy/xylene marine coating solvents
  • Amphibious dry + subsea water-blocked: Silicone water-blocking compound and swelling tapes let one crawler transition seamlessly across the waterline from dry hull plates to submerged draft zones
  • 1,000 V servo power + Cat 6 / FIMT / Coax: Combines 0.6/1 kV Class 6 servo drive cores (2.5–16 mm²) with 100-ohm subsea Cat 6, RS-485/CAN pairs, 75-ohm video coax or G.657.A2 optical fibers (covering 13XM553 to 26XM520)
  • Continuous bulk reel, MOQ 50 m: Delivered as continuous bulk cable on wooden drums with heat-shrink water-blocking end caps (separate from external UHP water lance hoses); MOQ 50 m in 7 to 45 working days
TF-MCR Magnetic Hull Crawling Robot Umbilical Cable — Ultralight Aramid/LCP Hydroblasting, NDT & Amphibious Crawler Tether (XM520–XM554) technical data
ParameterValue
Rated voltage0.6/1 kV (1000 V) servo power cores; 250 V to 500 V control, coaxial and Cat 6 Ethernet pairs
Air weight and hang load112 to 230 kg/km on compact NDT/amphibious builds (10 to 14.2 mm OD); 235 to 740 kg/km on 4G2.5 to 4G16 shipyard power crawlers
Tensile strength memberNon-metallic LCP yarn or aramid fiber braid rated 3.1 kN to 35 kN minimum breaking load (up to 65% lighter than steel wire armour)
Outer jacket durabilityHydrolysis- and UV-stabilized cut-resistant polyether PUR resistant to UHP hydroblasting mist, abrasive grit, seawater and marine paint solvents
Supply form and MOQContinuous bulk cable on wooden reels with heat-shrink water-blocking end caps (connectors installed by client); MOQ 50 m in 7 to 45 working days
Minimum bending radius5 x OD static and 10 x OD dynamic flexing over constant-tension crawler payout winches and gunwale roller guides
Operating temperature-30 °C to +80 °C continuous ambient across cold winter dry docks, hot sun-baked steel decks (+70 °C surface) and submerged splash zones

TF-MCR (4G2.5–4G16) Vertical Shipyard Crawler Power-Hybrid Schedule

TF-MCR Shipyard Magnetic Hull-Crawling Robot Power-Data-Optical Schedule (25–40 m Vertical Hydroblasting, Coating & Heavy NDT Series)
Model & Power Size0.6/1 kV Power CoresControl, Cat 6 & Fiber UnitsNom. OD (mm)Nom. Air Weight (kg/km)Min. Breaking Load (kN)30 m Vertical Hang MassNext step
TF-MCR 4G2.5+Cat64G2.5 mm² Class 6 (Shielded)Subsea Cat 6 + 2×2×0.34 mm²14.823512.07.1 kgRequest this size
TF-MCR 4G4+Cat6+2TSP4G4.0 mm² Class 6 (Shielded)Subsea Cat 6 + 2×2×0.50 mm²16.931016.09.3 kgRequest this size
TF-MCR 4G6+4FO+2TSP4G6.0 mm² Class 6 (Shielded)4 SM/MM FIMT + 2×2×0.50 mm²19.241522.012.5 kgRequest this size
TF-MCR 4G10+4FO+Cat64G10 mm² Class 6 (Shielded)4 SM FIMT + Subsea Cat 622.656028.016.8 kgRequest this size
TF-MCR 4G16+6FO+2TSP4G16 mm² Class 6 (Shielded)6 SM/MM FIMT + 2×2×0.75 mm²26.474035.022.2 kgRequest this size

TF-MCR (XM520–XM554) Compact NDT & Amphibious Crawler Schedule

TF-MCR Compact Amphibious & NDT Crawler Hybrid Tether Schedule (Cross-Reference 13XM553, 14XM523, 6XM551, 24XM521, 18XM522, 4XM554 & 26XM520)
Model & Reference CodeElectrical Conductors & VoltageCoax / Ethernet / Optical UnitNom. OD (mm)Air / Seawater Wt (kg/km)Breaking Load / Max SWLMin. Dyn. Bend RadiusNext step
TF-MCR 13XM55312 × 0.22 mm² (24 AWG, 500 V)1 × 75 Ω Coax (95% TCWB)10.0115 / 17960 kg / 240 kg100 mmRequest this size
TF-MCR 14XM52310 × 0.34 mm² Tinned Cu (1,000 V)2 SM (9/125) + 2 MM (50/125) PBT10.4112 / 25320 kg / 80 kg110 mmRequest this size
TF-MCR 6XM5512 × 16 AWG Power (1,000 V)2 × 2 × 24 AWG 100 Ω STP (250 V)11.0117 / 19960 kg / 240 kg110 mmRequest this size
TF-MCR 24XM52116 × 24 AWG Control (500 V)4 × 2 × 26 AWG Subsea Cat 5 (100 Ω)11.1131 / 32320 kg / 80 kg110 mmRequest this size
TF-MCR 18XM52210 × 0.50 mm² Tinned Cu (1,000 V)4 SM + 4 MM Stainless FIMT11.2156 / 54480 kg / 120 kg140 mmRequest this size
TF-MCR 4XM5544 × 2.50 mm² Class 5 (1,000 V)85% Tinned Cu Overall Braid Screen13.0219 / 83960 kg / 240 kg130 mmRequest this size
TF-MCR 26XM52018 × 22 AWG Control (500 V)4 × 2 × 24 AWG Subsea Cat 6 (100 Ω)14.2230 / 68480 kg / 120 kg170 mmRequest this size

Engineering note on 2,500–3,000 bar UHP hydroblasting hoses: ultra-high-pressure water-jetting lances carry extreme burst energy and have shorter replacement cycles than electrical umbilicals. Industry best practice pairs a continuous TF-MCR electrical/optical umbilical with an externally sleeve-banded UHP thermoplastic lance hose so a pinhole water-jet leak never injects 2,800 bar water inside the electrical jacket.

ASCII part references for BOM and ERP entry: TF-MCR-4G2P5, TF-MCR-4G4, TF-MCR-4G6, TF-MCR-4G10, TF-MCR-4G16, TF-MCR-13XM553, TF-MCR-14XM523, TF-MCR-6XM551, TF-MCR-18XM522, TF-MCR-4XM554, TF-MCR-26XM520, TF-MCR-24XM521.

Standards

TF-MCR Conductor, Ethernet & Fiber Reference Standards

TF-MCR Magnetic Hull Crawling Robot Umbilical Cable — Ultralight Aramid/LCP Hydroblasting, NDT & Amphibious Crawler Tether (XM520–XM554) standards and test references
Standard or specificationApplication
IEC 60228 Class 5 / Class 6 & Thin-Wall HDPE / XLPE InsulationHigh-strand-count copper conductors with high-dielectric thin-wall polyolefin insulation minimizing vertical hanging mass per meter.
IEC 61156 / TIA-568 Cat 6 & IEC 60794 Optical Fiber Integrity100-ohm differential impedance screened twisted pairs and bend-insensitive G.657.A2 optical fibers under constant-tension winch payout.

Certifications and document support

TEBAOFLEX ISO 9001 quality system and tensile/electrical factory verification

IEC 60228 — Conductors of insulated cables (Class 5 and Class 6 flexible stranding)

IEEE 802.3 Ethernet transmission reference for industrial & marine robotics

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.