Oil and Gas Cables TEBAOFLEX

TF-TANKCRAWL Cargo Oil Tank (COT), FPSO & Petrochemical Sludge Crawler Antistatic Oil-Resistant Umbilical Cable

TF-TANKCRAWL (TF-TANKCRAWL-UMB) is an electrostatic-dissipative (antistatic <10^8 Ω), aromatic-hydrocarbon-resistant robotic umbilical cable engineered for tracked and magnetic crawlers performing no-man-entry crude-oil sludge removal, deslopping and inspection inside VLCC Cargo Oil Tanks (COT), FPSO hulls and API 650 petrochemical storage tanks.

Product information
SKU
TF-TANKCRAWL-UMB
Brand
TEBAOFLEX
Product overview

TF-TANKCRAWL tank-cleaning crawler umbilicals deliver 250 V instrumentation/solenoid control, 0.6/1 kV explosion-zone motor power, gigabit Cat 6 / optical video, optional nitrogen (N2) enclosure-purge tubing and optional 250–350 bar hydraulic power across Ø 16.4 mm to Ø 54.0 mm antistatic, hydrocarbon-impervious umbilical constructions.

Non-man-entry (NME) robotic cleaning of VLCC Cargo Oil Tanks (COT), FPSO slop tanks, refinery API 650 crude storage tanks and rail/barge chemical tanks destroys ordinary rubber and standard marine PUR cables within days: aromatic hydrocarbons (benzene, toluene, xylene), naphtha, gas condensate and H2S-bearing paraffinic sludge swell conventional elastomers, delaminate jackets and attack copper conductors, while insulating plastic sheaths accumulate dangerous static charges sliding over deck manway rollers. TF-TANKCRAWL combines tinned copper conductors, hydrocarbon-barrier inner layers, high-modulus aramid strength braiding (eliminating exposed external steel wires that could strike mechanical sparks) and a dissipative (< 10^8 Ω surface resistance) hydrocarbon-compounded outer sheath.

Note on hazardous-area compliance: under EU Directive 2014/34/EU, bulk cables are passive components and are never issued standalone ATEX certificates; TF-TANKCRAWL provides verified antistatic surface resistance, concentric tinned-copper braid earthing, blue-sheathed intrinsically safe (IS) sub-pair segregation options and optional N2 purge ducts so robot OEMs can certify their complete Zone 0 / Zone 1 tank-cleaning system. Bulk cable MOQ 50 m, delivered in 7 to 45 working days.

Explore the oil, gas and petrochemical cable range for related configurations.

Construction

TF-TANKCRAWL Antistatic Oil-Tank Crawler Cable Construction

Engineered with tinned copper conductors, aromatic-hydrocarbon chemical barriers, tinned-copper braid earthing, non-sparking aramid tensile strength and antistatic outer sheathing.

Clean 2D circular engineering cross-section of TF-TANKCRAWL antistatic tank-cleaning crawler cable showing black dissipative outer sheath, golden aramid tensile braid, silver tinned-copper braid shield, barrier tape, four tinned-copper power cores, two shielded IS pairs and yellow 4-fiber unit
Cross-section: fluoropolymer/PA chemical barrier, >=85% tinned-copper braid screen and non-sparking aramid braid engineered for Zone 0/1 tank crawler OEMs.
TF-TANKCRAWL Cargo Oil Tank (COT), FPSO & Petrochemical Sludge Crawler Antistatic Oil-Resistant Umbilical Cable construction
ComponentMaterial and construction
1. Tinned Copper Power, Control & Blue-Coded IS Signal PairsIEC 60228 Class 5/6 tinned copper conductors (preventing H2S sour-crude black-plague corrosion) insulated with crosslinked XLPE or fluoropolymer ETFE; optional separately foil-screened blue-insulated pairs for intrinsically safe (Ex i) gas/sonar circuits.
2. Optical Fiber, Cat 6 Video & Optional N2 Purge / Hydraulic TubesStainless-steel or polyamide-jacketed G.657.A2 optical fibers, 100-ohm Cat 6 / 75-ohm coax, optional 6–8 mm polyamide nitrogen (N2) positive-pressure purge duct, or 250–350 bar SAE 100R8 hydraulic hoses.
3. Aromatic Hydrocarbon Barrier & 85% Tinned Copper Braid ScreenFuel- and BTX-resistant fluoropolymer/polyamide barrier tape plus >=85% coverage tinned-copper overall braid with continuous tinned drain wire for equipotential bonding.
4. Non-Metallic High-Modulus Aramid Retrieval Braid (12–40 kN MBL)High-strength aramid fiber braid carries crawler vertical hoisting loads through overhead tank Butterworth openings and manways with zero exposed external steel armour.
5. Electrostatic-Dissipative (< 10^8 Ω) Crude- & Solvent-Resistant SheathSemi-conductive / antistatic matte-black compounded polyurethane-elastomer alloy sheath (with thin yellow visibility stripe) resistant to crude oil, naphtha, condensate, diesel, caustic degreasers and +85 °C hot-water washdowns.

TF-TANKCRAWL Control, Power, N2-Purge & Hydraulic Codes

  • TF-TANKCRAWL CTRL-12C1.5: Low-voltage solenoid, gas-detector, sonar and camera control umbilical for hydraulically driven tank-sludge crawlers
  • TF-TANKCRAWL 4G2.5..4G16: 0.6/1 kV ETFE/XLPE electric crawler drive umbilicals with blue-coded Ex i pairs, Cat 6 / FIMT fibers and antistatic jacket
  • N2-PURGE-19: Integrates a 6 mm ID polyamide nitrogen purge micro-duct maintaining positive overpressure inside Ex p robot housings
  • EH-2X38 / EH-2X12: 250–350 bar twin-hose electro-hydraulic tank-crawler umbilicals encased in a single antistatic BTX-resistant outer sheath
  • < 10^8 Ω Antistatic: Electrostatic-dissipative carbon-alloy outer sheath preventing triboelectric spark buildup across tank hatches and rollers
Applications

TF-TANKCRAWL VLCC COT, FPSO & API 650 Tank Desludging Duty

Built for no-man-entry (NME) tracked and magnetic tank-cleaning crawlers across crude oil tankers, FPSOs, petrochemical terminals and refinery turnarounds.

Tracked sludge-cleaning crawler robot operating inside a steel crude-oil storage tank floor covered in dark oil residue while trailing a black antistatic TF-TANKCRAWL umbilical cable through a roller-protected tank manway
No-man-entry crude-oil tank desludging crawler deployed through a roller manway with an antistatic TF-TANKCRAWL umbilical.
  • VLCC, Suezmax and Aframax Cargo Oil Tank (COT) and slop-tank robotic desludging, crude-oil washing (COW) and pre-drydock inspection crawlers.
  • FPSO / FSO offshore floating storage tank bottom-sludge vacuum crawlers operating while adjacent tanks remain in service.
  • Onshore API 650 crude-oil, naphtha, condensate, diesel and jet-fuel storage tank sludge-liquefaction and ultrasonic floor-scan robots.
  • Refinery API separator, coker pit, chemical barge and wastewater lagoon hazardous-sludge dredging crawlers.

TF-TANKCRAWL Tank Umbilical vs Hull Crawler & Mud Cables

TF-TANKCRAWL COT/Storage-Tank Crawler Umbilical vs TF-MCR Exterior Hull Crawler Cable vs Fixed Offshore Mud-Resistant Cable
Cable FamilyStatic & Hydrocarbon ProtectionDynamic / Retrieval RatingIntended Operating Zone
TF-TANKCRAWL (this page)Antistatic (<10^8 Ω) + crude/naphtha/BTX barrier14–40 kN non-sparking aramid manway hoistVLCC cargo oil tanks (COT), FPSO & API 650 sludge crawlers
TF-MCR Magnetic Hull CableStandard seawater/paint-solvent PUR (insulating)Ultralight 112–740 kg/km for 30 m outer hull climbsOpen-air dry-dock hydroblasting, painting & NDT hull robots
NEK 606 BFOU / RFOU Mud CableDrilling-mud thermoset SHF2 (fixed installation)Heavy GSWB armour (not built for crawler reeling)Fixed topside wiring on offshore drilling rigs & FPSOs

Operating on open-air dry-dock exterior ship hulls rather than inside enclosed hydrocarbon cargo tanks? Choose lighter TF-MCR Magnetic Hull Crawling Robot Umbilical Cable.

TF-TANKCRAWL Tank-Cleaning Crawler Umbilical RFQ Checklist

  • Tank environment & media: sour crude oil, naphtha, gas condensate, diesel, aromatic solvents, or +85 °C steam/hot-water Butterworth washing.
  • Crawler drive & protection concept: hydraulic crawler with low-voltage Ex i / Ex d control (CTRL-12C1.5), N2-purged Ex p housing, or 0.6/1 kV Ex d electric drive.
  • Exact power cores, blue-coded individually screened IS pairs, optical fibers/coax, and any internal N2 purge tube or 250–350 bar hydraulic hoses.
  • Maximum manway roller bend radius, vertical tank depth (e.g., 25 m VLCC COT vs 60 m onshore run) and required Ex cable gland clamping OD range.
  • Continuous length per reel (supplied as bulk cable with sealed end caps; MOQ 50 m, lead time 7 to 45 working days).

Related selection resources

TF-TANKCRAWL Cargo Oil Tank & Sludge Crawler Umbilical FAQ

Why is an antistatic outer sheath (< 10^8 Ω) critical on TF-TANKCRAWL cargo oil tank crawler umbilicals?

Below 10^8 Ω surface resistance bleeds off triboelectric static charges continuously to grounded deck rollers and manway guides as the umbilical drags through dry hydrocarbon scale or oil mist, preventing electrostatic brush discharges in vapor-rich tank atmospheres.

Are TF-TANKCRAWL or other bulk industrial cables issued standalone ATEX certificates?

No — under EU Directive 2014/34/EU, bulk cables are classified as passive components and cannot legally bear a standalone ATEX mark; instead, TF-TANKCRAWL is engineered with IEC 60079-0 antistatic sheathing, compact barrier-gland bedding, >=85% tinned-copper earthing and optional Ex i / N2-purge elements for OEM system certification.

How does TF-TANKCRAWL resist swelling and copper blackening in sour crude oil, naphtha and condensate?

100% tinned copper conductors block H2S sulfide attack, while crosslinked ETFE/XLPE core insulation, a fluoropolymer/polyamide chemical barrier tape and a compounded hydrocarbon-resistant PUR alloy stop BTX aromatic and naphtha permeation.

Why use internal aramid fiber braiding instead of external galvanized steel wire armour on TF-TANKCRAWL?

14 to 40 kN non-metallic internal aramid braiding provides emergency vertical crawler retrieval strength through overhead Butterworth hatches at 65% lower weight while eliminating exposed steel wires that could cause mechanical friction sparks against steel tank coamings.

What is the minimum order quantity and delivery lead time for TF-TANKCRAWL tank-cleaning crawler umbilicals?

50 m minimum order quantity per specification, delivered as continuous bulk cable on wooden drums with sealed end caps in 7 to 45 working days.

Specifications

TF-TANKCRAWL Antistatic Electric, N2-Purge & Hydraulic Schedule

TF-TANKCRAWL <10^8 Ω Antistatic Sheath, BTX Barrier & 50 m MOQ

  • Antistatic outer sheath (< 10^8 Ω): Carbon-compounded electrostatic-dissipative black jacket with yellow ID stripe prevents static charge accumulation when dragging across tank manways and dry hydrocarbon scale (IEC 60079-0 guidance)
  • Crude, naphtha & BTX sludge resistant: Crosslinked ETFE/XLPE cores, fluoropolymer/polyamide chemical barrier and compounded oil-resistant PUR alloy withstand sour crude oil, naphtha, condensate, diesel, aromatics and +85 °C tank washing
  • Aramid tensile & TCWB EMC screen: High-modulus aramid braid (12–40 kN MBL) enables vertical tank-manway retrieval without heavy steel armour spark risk, backed by 85%+ tinned-copper braid + drain wire grounding
  • Electric, N2-purged or hydraulic builds: Supports low-voltage solenoid/camera control for hydraulic crawlers, 0.6/1 kV drive power, internal N2 purge-gas micro-ducts, or co-cabled 250–350 bar hydraulic hoses
  • Continuous bulk drum, MOQ 50 m: Supplied in continuous 60 m, 100 m, 150 m or custom lengths (MOQ 50 m) on wooden reels with sealed end caps in 7 to 45 working days
TF-TANKCRAWL Cargo Oil Tank (COT), FPSO & Petrochemical Sludge Crawler Antistatic Oil-Resistant Umbilical Cable technical data
ParameterValue
Rated voltage300/500 V instrumentation/solenoid builds and 0.6/1 kV (1000 V) crawler drive power builds; separate 250 V screened telemetry pairs
Electrostatic surface resistanceAntistatic outer sheath below 10^8 ohm surface resistance per IEC 60079-0 electrostatic guidance, plus 85% tinned-copper overall earth screen
Hydrocarbon and wash resistanceResistant to sour crude oil, paraffin sludge, naphtha, condensate, diesel, kerosene, BTX aromatics and +85 °C hot-water tank washing
Tensile retrieval strengthNon-sparking internal aramid fiber braid rated 12 kN to 40 kN minimum breaking load for vertical Butterworth/manway recovery
Supply form and MOQContinuous bulk cable on wooden drums with sealed end caps (Ex cable glands/connectors terminated by OEM); MOQ 50 m in 7 to 45 working days
Operating temperature-30 °C to +85 °C continuous (+90 °C XLPE / +150 °C ETFE internal core insulation options for steam-cleaned tanks)
Passive component engineeringDesigned with compact round concentric bedding for Ex d / Ex e / Ex i barrier gland compression (cables carry no standalone ATEX mark)

TF-TANKCRAWL Antistatic Electric & Control Tank-Crawler Schedule

TF-TANKCRAWL Antistatic Crude-Oil & Petrochemical Tank-Cleaning Crawler Electrical/Optical Schedule
Model & Crawler ArchitecturePower & Solenoid ConductorsIS Pairs, Video & FiberNom. OD (mm)Sheath Surface ResistanceAramid MBL (kN)Bulk Reel MOQNext step
TF-TANKCRAWL CTRL-12C1.512 × 1.5 mm² Tinned Cu (300/500 V)2×2×0.50 IS Pairs + 75 Ω Coax + 4 SM FO16.4< 10^8 Ω (Antistatic)1450 mRequest this size
TF-TANKCRAWL 4G2.5+Cat64G2.5 mm² XLPE/ETFE (0.6/1 kV)Shielded Cat 6 + 2×2×0.34 mm² IS17.8< 10^8 Ω (Antistatic)1650 mRequest this size
TF-TANKCRAWL 4G4+4FO+2TSP4G4.0 mm² XLPE/ETFE (0.6/1 kV)4 SM/MM FIMT + 2×2×0.50 mm² IS20.2< 10^8 Ω (Antistatic)2250 mRequest this size
TF-TANKCRAWL 4G6+4FO+2TSP4G6.0 mm² XLPE/ETFE (0.6/1 kV)4 SM/MM FIMT + 2×2×0.50 mm² IS22.8< 10^8 Ω (Antistatic)2650 mRequest this size
TF-TANKCRAWL 4G10+6FO+2TSP4G10 mm² XLPE/ETFE (0.6/1 kV)6 SM/MM FIMT + Subsea/Tank Cat 626.5< 10^8 Ω (Antistatic)3250 mRequest this size
TF-TANKCRAWL 4G16+6FO+2TSP4G16 mm² XLPE/ETFE (0.6/1 kV)6 SM/MM FIMT + 3×2×0.50 mm² IS30.4< 10^8 Ω (Antistatic)4050 mRequest this size

TF-TANKCRAWL Nitrogen-Purged & Electro-Hydraulic Sludge Crawler Schedule

TF-TANKCRAWL Nitrogen-Purged (Ex p) & Electro-Hydraulic Tank-Sludge Crawler Umbilical Schedule
Model & Purge / Hydraulic BuildInternal Gas Duct or Hydraulic HosesElectrical & Optical ElementsNom. OD (mm)Barrier & Outer JacketAramid MBL (kN)Bulk Reel MOQNext step
TF-TANKCRAWL N2-PURGE-191 × 6 mm ID Polyamide N2 Purge Tube (15 bar)4G2.5 mm² + 4×2×0.50 STP + 4 SM FO21.6ETFE/PA Barrier + Antistatic PUR2050 mRequest this size
TF-TANKCRAWL EH-2X38-250B2 × 3/8" SAE 100R8 Hoses (250 bar WP)8 × 1.0 mm² + 2×2×0.34 IS + 4 SM FO42.0BTX Barrier + Antistatic Oil-PUR3050 mRequest this size
TF-TANKCRAWL EH-2X12-350B2 × 1/2" SAE 100R8 Hoses (350 bar WP)12 × 1.5 mm² + 2×2×0.50 IS + 4 SM FO54.0BTX Barrier + Antistatic Oil-PUR3850 mRequest this size

Important hazardous-area cable note: many hydraulic tank-cleaning crawlers keep high power hydraulic and carry only 12–24 V Ex i / Ex d camera, sonar, gas-detector and valve signals over TF-TANKCRAWL CTRL-12C1.5, whereas pressurized (Ex p) electric crawlers use TF-TANKCRAWL N2-PURGE-19 to maintain continuous nitrogen overpressure inside the robot housing.

ASCII part references for BOM and ERP entry: TF-TANKCRAWL-CTRL-12C1P5, TF-TANKCRAWL-4G2P5, TF-TANKCRAWL-4G4, TF-TANKCRAWL-4G6, TF-TANKCRAWL-4G10, TF-TANKCRAWL-4G16, TF-TANKCRAWL-N2-PURGE-19, TF-TANKCRAWL-EH-2X38-250B, TF-TANKCRAWL-EH-2X12-350B.

Standards

TF-TANKCRAWL IEC 60079-0/14 & Hydrocarbon Resistance Standards

TF-TANKCRAWL Cargo Oil Tank (COT), FPSO & Petrochemical Sludge Crawler Antistatic Oil-Resistant Umbilical Cable standards and test references
Standard or specificationApplication
IEC 60079-0 / IEC 60079-14 Hazardous-Area Cable Construction GuidanceAntistatic outer sheath (< 10^8 Ω surface resistance), compact solid-filled gas-tight bedding for barrier glands, and blue-core Ex i pair screening.
IEC 60811 / IRM 903 Oil, Diesel & Aromatic Hydrocarbon ImmersionCrosslinked ETFE/XLPE core insulation and fluoropolymer-barrier compounded PUR alloy resisting crude oil, naphtha, condensate and diesel swell.

Certifications and document support

TEBAOFLEX ISO 9001 quality management and surface-resistance / dielectric factory testing

IEC 60092 / IEC 60079 Electrical & Offshore Cable Standards at IEC Webstore

ISO 15156 — Sour H2S oil & gas environment material selection reference

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.