CÂBLES MINIERS ET DE TUNNELAGE Modèle / construction

Type 307 BS 6708 1900/3300 V Coal Cutter Cable

Type 307 mining cable for excavating, crushing and coal-cutting equipment, with the source-defined 1900/3300 V rating and 7.5 kV test reference.

  • Model: Type 307
  • Conductor and insulation: flexible tinned copper with the insulation and core construction listed for this model in the supplied PDF
  • Screen, pilot, earth and armour arrangement preserved from the source datasheet
  • Heavy-duty chloroprene or PCP outer protection as listed for this model
  • Original Type datasheet available as the product download

Send the equipment, voltage, conductor area, route, quantity and document requirements for an RFQ.

Informations sur le produit
Marque
Modèle / construction
Présentation du produit

Type 307 for excavating, crushing and coal-cutting equipment

Type 307 mining cable is specified in the supplied BS 6708 datasheet for excavating, crushing and coal-cutting equipment. This page keeps the source-listed voltage, test reference, core functions and dimensional tables together so a procurement engineer can compare the requested model against the cable marking and the equipment connection. The editorial focus is the unscreened-pilot 3.3 kV coal-cutter configuration, not a generic promise of performance.

The supplied construction uses three copper/nylon screened phase cores, one unscreened pilot core and a bare copper earth conductor, laid up together and covered by a heavy-duty chloroprene sheath. That arrangement matters because Type 307 has an unscreened single pilot; Type 307M screens the pilot and Type 307S uses an unscreened three-core pilot unit. The family should therefore be selected by model, core function and installation route as well as by voltage. The gamme de câbles pour l'exploitation minière et le creusement de tunnels provides the wider TEBAOFLEX product context.

  • Choisir par : confirm the existing pilot arrangement, phase area, cable handling route and 1900/3300 V equipment interface.
  • Confirmez avant de commander : existing sheath marking, conductor area, cable length, route, support or handling system, terminations and the required inspection documents.
  • Do not infer: values not listed in the supplied PDF, such as a different current basis, water/oil/UV performance, certification scope or mechanical interchangeability.

Le BS 6708 mining cable replacement guide gives procurement teams a concise way to compare the Type 307 pilot and screening variants before selecting a 3.3 kV route.

For a technical quotation, send the equipment nameplate or existing cable marking, voltage and size requirement, installation conditions, quantity, destination and any project-specific test or documentation requirement.

Construction

Type 307 construction

The cross-section below is the supplied construction drawing for Type 307. The ordering decision is driven by Type 307 has an unscreened single pilot; Type 307M screens the pilot and Type 307S uses an unscreened three-core pilot unit.

Type 307 cable cross-section showing the supplied power, pilot, earth, screen and protection arrangement
Supplied Type 307 cross-section; the exact core and armour arrangement must be checked against the product datasheet.

Source-listed construction

Élément de constructionValeur indiquée dans la source
ConducteurElectrolytic stranded tinned copper wire, IEC 60228 Class 5
IsolationEPR; earth conductor is not insulated
ÉcranTinned copper and nylon braided screen over phase cores; pilot core is not screened
Lay-upAll cores laid up in contact with the bare copper earth conductor
GaineHeavy-duty chloroprene outer sheath
Agencement de baseThree screened phase cores, one unscreened pilot core and a bare copper earth conductor

Do not use the drawing as a substitute for the dimensional tables. Confirm the cable end preparation, screen and earth termination, armour bonding and machine interface with the equipment documentation before installation.

Applications

Type 307 applications

Type 307 mining cable application with underground longwall mining equipment
Media-library application scene showing underground longwall mining equipment; used for application context, not as a model-specific construction proof.

The supplied datasheet identifies this cable for excavating, crushing and coal-cutting equipment. Google result patterns for the BS 6708 family also separate cables by equipment duty, voltage class, core function and whether the route is armoured, screened, flat or auxiliary. That is why this page keeps the Type 307 construction separate from nearby Type numbers.

  • Primary duty: excavating, crushing and coal-cutting equipment.
  • Model boundary: Type 307 has an unscreened single pilot; Type 307M screens the pilot and Type 307S uses an unscreened three-core pilot unit.
  • Project check: match the cable marking, core map, voltage, termination, route geometry and handling method to the machine drawing.
  • Environmental review: confirm the actual mine/quarry conditions and any authority, inspection or documentation requirements; do not infer a certification or material-resistance claim from the model number.

If the pilot-screen requirement changes, use the Type 307M screened-pilot cable as the close model comparison and verify the monitoring circuit before procurement.

The cable should be released only after the equipment route, required length, conductor area, core functions and connection details are agreed. If the intended duty is different from the source-listed application, request an engineering review through the quotation process.

Caractéristiques

Type 307 specifications

The summary below identifies the supplied model family. The source-transcribed tables that follow retain the PDF's dimensional, electrical and construction values, including available sizes, resistance, current, diameter, mass, bending or pulling data when the PDF provides them.

Selection itemSource-linked value
ModèleType 307
Tension nominale1900/3300 V
Tension d'essai7.5 kV
Applicationexcavating, crushing and coal-cutting equipment
Norme du produitBS 6708

Complete source-transcribed technical tables

Source PDF: BS6708_TYPE_307_1900_3300V_POWER_SUPPLY_CABLE_datasheet.pdf; 3 pages; 4 extracted tables. Values are not recalculated or replaced by third-party values.

Source table 1, PDF page 1
ParamètreValeur
ConducteurElectrolytic, stranded, tinned copper wire, IEC 60228 Class 5
IsolationEPR; the earth conductor is not insulated
SéparateurColored textile tape for core identification
ÉcranTinned copper and nylon braided screen over phase cores; pilot core is not screened
Lay-upAll cores laid up in contact with the bare copper earth conductor
LiterieRubber based bedding compound
gaine extérieureHeavy duty chloroprene outer sheath
Source table 2, PDF page 1
ParamètreValeur
StandardBS 6708
Tension nominale1900/3300 V
Tension d'essai7.5 kV
Agencement de baseThree screened phase cores, one unscreened pilot core and a bare copper earth conductor
Source table 1, PDF page 2
CABLE DIMENSIONS
Paramètre3x25 +25+163x35 +25+163x50 +35+253x70 +50+353x95 +50+503x120 +70+703x150 +70+95
Phase conductor cross section mm23x253x353x503x703x953x1203x150
Phase conductor stranding196/0.40276/0.40396/0.40360/0.50475/0.50608/0.50756/0.50
Phase conductor diameter nominal mm7.008.5010.0011.7013.5015.4017.20
Phase insulation diameter nominal mm13.1014.7015.7017.7019.1021.4023.00
Phase screen diameter mm15.5017.1017.7019.7021.1023.4025.00
Earth conductor cross section mm21x251x251x351x501x501x701x95
Earth conductor stranding196/0.40196/0.40276/0.40396/0.40396/0.40360/0.50475/0.50
Earth conductor diameter nominal mm7.007.008.5010.0010.0011.7013.50
Pilot conductor cross section mm21x161x161x251x351x501x701x95
Pilot conductor stranding126/0.40126/0.40196/0.40276/0.40396/0.40360/0.50475/0.50
Pilot conductor diameter nominal mm5.505.507.008.5010.0011.7013.50
Pilot insulation diameter nominal mm11.6011.6013.1014.7015.7017.7019.10
Minimum overall diameter mm47.451.656.862.868.973.475.9
Maximum overall diameter mm49.954.659.865.872.777.279.7
Minimum bending radius mm400440480525580615640
Maximum pulling tension kgf64083012001680200020002000
Approximate cable weight kg/km400048006150760092501120013000
Copper weight kg/km1654194826663482434654506000
Source table 1, PDF page 3
ELECTRICAL DETAILS
Paramètre3x25 +25+163x35 +25+163x50 +35+253x70 +50+353x95 +50+503x120 +70+703x150 +70+95
Continuous current rating at 25 deg C ambient A110135170205250295320
Intermittent current rating at 25 deg C ambient A130155210255315360385
Phase conductor DC resistance at 20 deg C ohm/km0.7950.5650.3930.2770.2100.1640.132
Pilot conductor DC resistance at 20 deg C ohm/km1.2401.2400.7950.5650.3930.2770.210
Three screens and earth in parallel DC resistance ohm/km0.500.500.350.350.280.280.14
Nominal reactance at 50 Hz ohm/km0.1250.1170.1130.1080.1050.1010.098
Nominal reactance at 60 Hz ohm/km0.1500.1410.1360.1290.1260.1210.118
Minimum insulation resistance at 20 deg C MOhm/km12501100950820720660600
3 phase voltage drop at full load mV/A/m1.691.210.850.610.480.390.32

Use the table values with the equipment drawing and approved termination plan. If the requested conductor area, current basis, mechanical limit or environmental condition is not listed in the supplied PDF, treat it as a quotation-stage confirmation item.

Normes

Type 307 standards and references

ObjetSource-linked reference
Norme du produitBS 6708
Tension nominale1900/3300 V
Tension d'essai7.5 kV
Source applicationexcavating, crushing and coal-cutting equipment

The product page preserves the BS 6708 reference appearing in the supplied PDF. The BSI record currently identifies BS 6708:1998 as withdrawn on 22 May 2026; this status note is a standards-reference update, not a claim that the product is currently certified or approved. See the official BSI BS 6708 scope record for the published status.

For an RFQ, state the required standard documents, inspection scope, test report, cable marking, destination rules and any replacement-equivalence requirement. The model number alone does not establish legal installation compliance.

Comparer par fonction

Options de câbles associées

Comparez ces options de câbles en fonction de la combinaison de services, du mouvement, de la charge, de la tension et des exigences de transmission.

devis basé sur l'ingénierie

Demandez une recommandation et un devis pour un câble.

Veuillez nous indiquer les services requis, la longueur du câble, les contraintes mécaniques, l'environnement, le type de terminaison et la quantité. Notre équipe examinera votre demande avant de vous établir un devis.

  • Veuillez inclure le nom du produit ou son SKU, ainsi que la longueur et la quantité de câble requises.
  • Joignez une fiche technique, un dessin ou une fiche de spécifications si disponible.

    Facultatif : joindre une spécification de câble, un dessin, une fiche technique ou une image du produit (PDF, DOC, DOCX, XLS, XLSX, CSV, JPG ou PNG ; maximum 10 Mo).

    En soumettant ce formulaire, vous acceptez que TEBAOFLEX utilise vos coordonnées et les fichiers fournis pour examiner votre demande et y répondre. Les fichiers servent à l'établissement du devis et aux échanges techniques relatifs à votre demande. Consultez notre politique de confidentialité. politique de confidentialité pour obtenir des informations à jour sur le traitement et la conservation des données.