Type 321 / Type 331 BS 6708 1900/3300 V Armoured Trailing Cable
Type 321 / Type 331 mining cable for mine roadway extensions and mechanically protected quarry trailing, with the source-defined 1900/3300 V rating and 6.5 kV test reference.
- Model: Type 321 / Type 331
- Conductor and insulation: flexible tinned copper with the insulation and core construction listed for this model in the supplied PDF
- Screen, pilot, earth and armour arrangement preserved from the source datasheet
- Heavy-duty chloroprene or PCP outer protection as listed for this model
- Original Type datasheet available as the product download
Send the equipment, voltage, conductor area, route, quantity and document requirements for an RFQ.
Type 321 / Type 331 for mine roadway extensions and mechanically protected quarry trailing
Type 321 / Type 331 mining cable is specified in the supplied BS 6708 datasheet for mine roadway extensions and mechanically protected quarry trailing. This page keeps the source-listed voltage, test reference, core functions and dimensional tables together so a procurement engineer can compare the requested model against the cable marking and the equipment connection. The editorial focus is the armoured roadway-extension family at 3.3 kV, not a generic promise of performance.
The supplied construction uses three power cores and one earth core laid around an elastomeric centre, with galvanized pliable wire armour and a heavy flame-retardant PCP jacket with blue stripe. That arrangement matters because Type 321 leaves the power cores unscreened; Type 331 adds composite copper/nylon phase screens. Both include an earth core and armouring. The family should therefore be selected by model, core function and installation route as well as by voltage. The gamme de câbles pour l'exploitation minière et le creusement de tunnels provides the wider TEBAOFLEX product context.
- Choisir par : confirm whether the project needs Type 321 unscreened power cores or Type 331 screened power cores, then check armour and route constraints.
- Confirmez avant de commander : existing sheath marking, conductor area, cable length, route, support or handling system, terminations and the required inspection documents.
- Do not infer: values not listed in the supplied PDF, such as a different current basis, water/oil/UV performance, certification scope or mechanical interchangeability.
Le Mining & Tunnelling solutions page provides project context when armour, phase screening and the higher-voltage trailing route must be reviewed together.
For a technical quotation, send the equipment nameplate or existing cable marking, voltage and size requirement, installation conditions, quantity, destination and any project-specific test or documentation requirement.
Type 321 / Type 331 construction
The cross-section below is the supplied construction drawing for Type 321 / Type 331. The ordering decision is driven by Type 321 leaves the power cores unscreened; Type 331 adds composite copper/nylon phase screens. Both include an earth core and armouring.

Source-listed construction
| Élément de construction | Valeur indiquée dans la source |
|---|---|
| Noyaux énergétiques | Three flexible tinned annealed copper conductors, MEPR insulated |
| Type 321 | Three unscreened power cores plus one unscreened earth core |
| Type 331 | Three copper/nylon screened power cores plus one unscreened earth core |
| Literie | Extruded PCP bedding sheath |
| Armure | Pliable galvanised steel wire armour |
| Overall sheath | Heavy-duty flame-retardant elastomeric compound, PCP black with blue stripe |
Do not use the drawing as a substitute for the dimensional tables. Confirm the cable end preparation, screen and earth termination, armour bonding and machine interface with the equipment documentation before installation.
Type 321 / Type 331 applications

The supplied datasheet identifies this cable for mine roadway extensions and mechanically protected quarry trailing. Google result patterns for the BS 6708 family also separate cables by equipment duty, voltage class, core function and whether the route is armoured, screened, flat or auxiliary. That is why this page keeps the Type 321 / Type 331 construction separate from nearby Type numbers.
- Primary duty: mine roadway extensions and mechanically protected quarry trailing.
- Model boundary: Type 321 leaves the power cores unscreened; Type 331 adds composite copper/nylon phase screens. Both include an earth core and armouring.
- Project check: match the cable marking, core map, voltage, termination, route geometry and handling method to the machine drawing.
- Environmental review: confirm the actual mine/quarry conditions and any authority, inspection or documentation requirements; do not infer a certification or material-resistance claim from the model number.
Where the power route moves to 3800/6600 V, review the Type 630/631 armoured mining cable as a separate voltage family rather than inferring compatibility from the trailing-cable format.
The cable should be released only after the equipment route, required length, conductor area, core functions and connection details are agreed. If the intended duty is different from the source-listed application, request an engineering review through the quotation process.
Type 321 / Type 331 specifications
The summary below identifies the supplied model family. The source-transcribed tables that follow retain the PDF's dimensional, electrical and construction values, including available sizes, resistance, current, diameter, mass, bending or pulling data when the PDF provides them.
| Selection item | Source-linked value |
|---|---|
| Modèle | Type 321 / Type 331 |
| Tension nominale | 1900/3300 V |
| Tension d'essai | 6.5 kV |
| Application | mine roadway extensions and mechanically protected quarry trailing |
| Norme du produit | BS 6708:1998 |
Complete source-transcribed technical tables
Source PDF: BS6708_TYPE_321_TYPE_331_1900_3300V_ARMOURED_TRAILING_CABLE_datasheet.pdf; 4 pages; 6 extracted tables. Values are not recalculated or replaced by third-party values.
| Paramètre | Valeur |
|---|---|
| Conducteur | Three flexible tinned annealed copper conductors, MEPR insulated |
| Type 331 | Three copper/nylon screened power cores plus one unscreened earth core |
| Type 321 | Three unscreened power cores plus one unscreened earth core |
| Lay-up | Power cores and earth core laid up around an elastomeric centre |
| Literie | Extruded PCP bedding sheath |
| Armure | Pliable galvanised steel wire armour |
| Overall sheath | Heavy duty flame retardant elastomeric compound, PCP black with blue stripe |
| Paramètre | Valeur |
|---|---|
| Standard | BS 6708:1998 |
| Tension nominale | 1900/3300 V |
| Tension d'essai | 6.5 kV |
| Phase identification | Red, yellow and brown |
| Type 331 screen | Composite copper/nylon braid over phase cores |
| TYPE 331 CABLE DIMENSIONS | |||||||
|---|---|---|---|---|---|---|---|
| Paramètre | 25 | 35 | 50 | 70 | 95 | 120 | 150 |
| Phase diameter over insulation and tape mm | 13.50 | 15.10 | 16.20 | 18.15 | 19.60 | 21.95 | 23.10 |
| Phase diameter over screen mm | 15.50 | 17.10 | 18.20 | 20.15 | 21.60 | 23.95 | 25.40 |
| Earth conductor nominal CSA mm2 | 16 | 25 | 35 | 50 | 70 | 70 | 70 |
| Earth diameter over insulation and tape mm | 15.50 | 17.10 | 18.20 | 20.15 | 21.60 | 23.95 | 25.40 |
| Diameter over inner sheath - minimum mm | 42.20 | 48.20 | 52.60 | 60.00 | 65.10 | 68.80 | 71.50 |
| Diameter over inner sheath - maximum mm | 44.70 | 50.70 | 55.60 | 63.00 | 68.90 | 72.60 | 74.00 |
| Overall diameter - minimum mm | 57.80 | 64.60 | 69.80 | 80.30 | 86.40 | 90.90 | 93.80 |
| Overall diameter - maximum mm | 61.60 | 68.40 | 73.80 | 84.60 | 90.70 | 95.20 | 98.10 |
| Minimum bending radius mm | 620 | 690 | 740 | 850 | 910 | 960 | 980 |
| Maximum pulling tension kgf | 540 | 780 | 1110 | 1560 | 2000 | 2000 | 2000 |
| Approximate cable weight kg/km | 6400 | 7800 | 9100 | 12400 | 14600 | 16300 | 18200 |
| TYPE 321 CABLE DIMENSIONS | |||||
|---|---|---|---|---|---|
| Paramètre | 35 | 50 | 70 | 95 | 120 |
| Phase diameter over insulation and tape mm | 15.10 | 16.20 | 18.15 | 19.60 | 21.95 |
| Earth conductor nominal CSA mm2 | 35 | 50 | 70 | 95 | 120 |
| Earth diameter over insulation and tape mm | 15.10 | 16.20 | 18.15 | 19.60 | 21.95 |
| Diameter over inner sheath - minimum mm | 44.30 | 51.30 | 56.40 | 63.80 | 67.50 |
| Diameter over inner sheath - maximum mm | 46.80 | 54.30 | 59.40 | 66.80 | 71.30 |
| Overall diameter - minimum mm | 60.30 | 68.30 | 74.40 | 84.90 | 89.40 |
| Overall diameter - maximum mm | 64.10 | 72.30 | 78.40 | 89.20 | 93.70 |
| Minimum bending radius mm | 640 | 720 | 790 | 890 | 940 |
| Maximum pulling tension kgf | 840 | 1200 | 1680 | 2000 | 2000 |
| Approximate cable weight kg/km | 4900 | 6400 | 7700 | 10800 | 12300 |
| TYPE 331 ELECTRICAL DETAILS | |||||||
|---|---|---|---|---|---|---|---|
| Paramètre | 25 | 35 | 50 | 70 | 95 | 120 | 150 |
| Continuous current rating at 25 deg C ambient A | 110 | 135 | 170 | 205 | 250 | 295 | 320 |
| Power conductor DC resistance at 20 deg C ohm/km | 0.795 | 0.565 | 0.393 | 0.277 | 0.210 | 0.164 | 0.132 |
| Earth conductor DC resistance at 20 deg C ohm/km | 1.240 | 0.795 | 0.565 | 0.393 | 0.277 | 0.277 | 0.277 |
| Screens in parallel DC resistance ohm/km | 1.350 | 0.800 | 0.700 | 0.690 | 0.840 | 0.550 | 0.550 |
| Armour DC resistance at 20 deg C ohm/km | 0.965 | 0.844 | 0.715 | 0.488 | 0.382 | 0.299 | 0.240 |
| Nominal reactance at 50 Hz ohm/km | 0.125 | 0.117 | 0.113 | 0.108 | 0.105 | 0.101 | 0.098 |
| Nominal reactance at 60 Hz ohm/km | 0.150 | 0.140 | 0.136 | 0.129 | 0.126 | 0.121 | 0.118 |
| Min. insulation resistance of power cores MOhm/km | 1250 | 1100 | 950 | 820 | 720 | 660 | 600 |
| 3 phase voltage drop at 50 Hz mV/A/m | 1.69 | 1.21 | 0.85 | 0.61 | 0.48 | 0.39 | 0.32 |
| TYPE 321 ELECTRICAL DETAILS | |||||
|---|---|---|---|---|---|
| Paramètre | 35 | 50 | 70 | 95 | 120 |
| Continuous current rating at 25 deg C ambient A | 135 | 170 | 205 | 250 | 295 |
| Power conductor DC resistance at 20 deg C ohm/km | 0.565 | 0.393 | 0.277 | 0.210 | 0.164 |
| Earth conductor DC resistance at 20 deg C ohm/km | 0.565 | 0.393 | 0.277 | 0.210 | 0.164 |
| Armour DC resistance at 20 deg C ohm/km | 0.990 | 0.760 | 0.530 | 0.400 | 0.320 |
| Nominal reactance at 50 Hz ohm/km | 0.117 | 0.113 | 0.108 | 0.105 | 0.101 |
| Nominal reactance at 60 Hz ohm/km | 0.140 | 0.136 | 0.129 | 0.126 | 0.121 |
| Min. insulation resistance of power cores MOhm/km | 1100 | 950 | 820 | 720 | 660 |
| 3 phase voltage drop at 50 Hz mV/A/m | 1.21 | 0.85 | 0.61 | 0.48 | 0.39 |
Use the table values with the equipment drawing and approved termination plan. If the requested conductor area, current basis, mechanical limit or environmental condition is not listed in the supplied PDF, treat it as a quotation-stage confirmation item.
Type 321 / Type 331 standards and references
| Objet | Source-linked reference |
|---|---|
| Norme du produit | BS 6708:1998 |
| Tension nominale | 1900/3300 V |
| Tension d'essai | 6.5 kV |
| Source application | mine roadway extensions and mechanically protected quarry trailing |
The product page preserves the BS 6708 reference appearing in the supplied PDF. The BSI record currently identifies BS 6708:1998 as withdrawn on 22 May 2026; this status note is a standards-reference update, not a claim that the product is currently certified or approved. See the official BSI BS 6708 scope record for the published status.
For an RFQ, state the required standard documents, inspection scope, test report, cable marking, destination rules and any replacement-equivalence requirement. The model number alone does not establish legal installation compliance.
Options de câbles associées
Comparez ces options de câbles en fonction de la combinaison de services, du mouvement, de la charge, de la tension et des exigences de transmission.
Type 245 Flexible Rubber Mining Cable 1.1–6.6 kV
Une option de câble similaire pour une application ou un profil de service différent.
Voir le produitCâble d'alimentation blindé pour l'industrie minière TYPE260
Une option de câble similaire pour une application ou un profil de service différent.
Voir le produitCâble souterrain pour mine de charbon de type 240, 1,1 kV à 11 kV
Une option de câble similaire pour une application ou un profil de service différent.
Voir le produitDemandez une recommandation et un devis pour un câble.
Veuillez nous indiquer les services requis, la longueur du câble, les contraintes mécaniques, l'environnement, le type de terminaison et la quantité. Notre équipe examinera votre demande avant de vous établir un devis.
- Veuillez inclure le nom du produit ou son SKU, ainsi que la longueur et la quantité de câble requises.
- Joignez une fiche technique, un dessin ou une fiche de spécifications si disponible.