CTD Profiling, Sonar Hydrophone Array & Deep-Ocean Oceanographic Cable (2,000–10,000 m)
Deep-ocean oceanographic, hydrographic and naval acoustic detection cables engineered for 2,000 m to 10,000 m full-ocean-depth service: Type 2.3 CTD-7000 (68 MPa steel-armored CTD umbilical), Type 2.4AF CTD-10000 (100 MPa synthetic-fiber ultra-light CTD umbilical, 25 kg/km in water), REF 57942 28-pair (40 ± 5 Ω) dynamic sonar cable, REF 52566 / 6050 4.5 kV 40 Ω sonar coax, REF 56427 / 50108 magnetic and acoustic detection cables, and REF 50580 / 39465 / 26896 2,000–2,500 m seismic, neutrino-telescope and sonar-buoy cables.
Deep-ocean conductivity-temperature-depth (CTD) rosette profiling, naval hull/towed sonar arrays and abyssal seismic or neutrino observatories demand specialized cables that maintain stable electrical impedance and optical attenuation under hydrostatic pressures up to 100 MPa (10,000 m). This series covers full-ocean-depth CTD winch umbilicals, matched-impedance 40 Ω sonar cables, armored acoustic/magnetic surveillance cables and 2,000–2,500 m electro-optical array backbones.
For shipboard hydrographic winches, Type 2.3 CTD-7000 (OD 10.6 mm) uses torque-balanced galvanized steel armor to deliver a ≥70 kN breaking load and ≥68 MPa (7,000 m) pressure rating. For ultra-deep hadal trenches down to 10,000 m+, Type 2.4AF CTD-10000 (OD 10.6 mm) replaces steel wire with high-modulus synthetic tensile fibers—slashing submerged weight in water from 320 kg/km down to just 25 kg/km while sustaining ≥29 kN breaking load and ≥100 MPa hydrostatic resistance.
For naval and coastal sonar systems, REF 57942 provides 28 individually copper-spun-shielded 0.34 mm² pairs tuned to 40 ± 5 Ω characteristic impedance inside a dynamic PUR sheath, complemented by REF 52566 / REF 6050 (4.5 kV peak, 40 Ω FEP/Neoprene transmitter coax), REF 56427 (stainless-steel-braided ETFE magnetic detection triplets) and REF 50108 (8,900 daN steel-armored acoustic detection cable).
Specify the model designation, deployment depth (2,000 m to 10,000 m), impedance requirement and drum length in your RFQ. TEBAOFLEX manufactures oceanographic and sonar cables from a 50 m minimum order quantity with a lead time of 7–45 working days.
Explore the marine, offshore and underwater cable range for related configurations.
For related deep-ocean armoured tow cables and fixed seabed observation umbilicals, compare: 39–45 Ohm Coaxial Armoured Tow Cable (double-steel-wire-armoured 39–45 Ohm coaxial tow cable for deep geophysical surveys); Seabed Ocean-Observation, Borehole Sensing & Submersible Aquaculture Composite Cable (stationary seabed observatory, borehole sensing, and offshore aquaculture composite cables). Verify 2,000 m to 10,000 m hydrostatic depth rating, torque balance, and low-capacitance pair impedance.
Construction
The representative construction illustrates the Type 2.4AF CTD-10000 Full-Ocean-Depth Tensile-Fiber CTD Umbilical (OD 10.6 mm, 100 MPa / 10,000 m) alongside the REF 57942 28-Pair 40 Ω Dynamic Sonar Cable (OD 25 mm): precision-insulated copper telemetry/power conductors or 28 individually tinned-copper-spun-shielded 40 Ω TPE-E pairs, pressure-resistant inner bedding, high-modulus synthetic tensile fiber armor (or double galvanized steel wire / stainless-steel braid armor) and a seawater-impervious polymer or polyurethane outer sheath.

| Component | Material and construction |
|---|---|
| CTD telemetry & power core (Type 2.3 & Type 2.4AF) | Low-loss copper power and real-time sea-cable telemetry conductors (≤10.0 Ω/km on Type 2.3 CTD-7000; ≤36.0 Ω/km on Type 2.4AF CTD-10000) with high-dielectric insulation (≥1,000 MΩ·km at DC 500 V). |
| Matched 40 Ω & 50–60 Ω sonar cores (REF 57942, 6050, 26896) | REF 57942: 28×2×0.34 mm² TPE-E pairs (40 ± 5 Ω, ≤180 pF/m) each with tinned-copper spun shield. REF 6050: 4.5 kV peak 40 Ω FEP-insulated sonar coax. REF 26896: 3 × 50–60 Ω silver-plated FEP/ETFE coax. |
| Subsea optical & seismic detection cores (REF 50580, 39465, 56427) | REF 50580: 21×9/125 μm SM fibers in 3 stainless-steel loose tubes (200 kpsi proof) + 9×1.0 mm² XLPE cores. REF 56427: 4 × KU 06-16 (3×1.34 mm²) ETFE-insulated and copper-braid-shielded triplets. |
| Hydrostatic water-blocking matrix (68 MPa to 100 MPa) | Void-free silicone or elastomeric water-blocking compound and high-density polyethylene (HDPE / PE) pressure-barrier sheaths verified up to 250–260 bar (REF 26896 / 50580), 68 MPa (Type 2.3) and 100 MPa (Type 2.4AF). |
| Armoring & tensile reinforcement | High-strength synthetic tensile fiber armor (≥29 kN on Type 2.4AF; 10,000–18,000 daN aramid braid on REF 39465/50580), stainless-steel braid (1,500 daN on REF 56427) or galvanized steel wire armor (70–90 kN on Type 2.3, REF 50108, REF 26896). |
| Outer protective sheath | Hydrolysis-resistant polyurethane (PUR), high-density polyethylene (HDPE) or marine polychloroprene (Neoprene on REF 6050) engineered for long-term immersion and low acoustic self-noise. |
Applications
Select the appropriate oceanographic or acoustic cable based on deployment depth (up to 10,000 m), winch traction capacity, characteristic impedance (40 Ω, 50–60 Ω or 120 Ω) and magnetic/acoustic signature constraints.

- Full-ocean-depth (7,000 m to 10,000 m+) shipboard CTD water-sampler rosette profiling, abyssal hydrographic winches and deep-trench physical oceanography (Type 2.3 CTD-7000 and Type 2.4AF CTD-10000).
- Inboard ship sonar transducer arrays, hull-mounted sonar domes and 4.5 kV high-power sonar transmitter feeds requiring 40 Ω matched impedance (REF 57942 28-pair dynamic cable and REF 52566 / REF 6050 coax).
- Coastal and harbour security magnetic-anomaly and underwater acoustic surveillance barriers requiring crush-resistant stainless-steel braid or 8,900 daN galvanized steel wire armor (REF 56427 and REF 50108).
- Deep-sea neutrino radiotelescope optical amplifier links (-2,500 m, 260 bar), seabed seismic detection lines (-2,000 m) and 250 bar towed sonar buoys (REF 50580, REF 39465 and REF 26896).
For broader armoured oceanographic cable architectures and multi-pair sensor leads, consult: Armoured Underwater Instrumentation Cables (application guide for armoured underwater instrumentation and hydrographic winch cables); Armoured Underwater Instrumentation Cable (heavy-duty armoured underwater instrumentation cable for subsea transducers and arrays). Confirm acoustic self-noise isolation, conductor DC loop resistance, and mechanical termination hardware.
Specifications
| Parameter | Value |
|---|---|
| Maximum operating water depth | 2,000–2,500 m / 250–260 bar (REF 39465, 26896, 50580); 7,000 m / 68 MPa (Type 2.3 CTD-7000); 10,000 m+ / 100 MPa (Type 2.4AF CTD-10000) |
| Tensile breaking load | 15 kN (REF 56427), 29 kN (Type 2.4AF), 70 kN (Type 2.3), 89–90 kN (REF 50108 / 26896), 100 kN (REF 39465), 180 kN (REF 50580) |
| Rated operating voltage | 500 V to 1,000 V (detection/oceanographic power cores); 4.5 kV peak (REF 52566 / REF 6050 sonar transmitter coax) |
| Characteristic impedance options | 40 Ω (REF 6050 sonar coax), 40 ± 5 Ω (REF 57942 28-pair sonar), 50–60 Ω (REF 26896 triple coax), 120 Ω (REF 39465 seismic pairs) |
| Insulation resistance | ≥1,000 MΩ·km at DC 500 V across Type 2.3 CTD-7000, Type 2.4AF CTD-10000 and REF 6050 sonar coaxial cable |
| Submerged weight optimization | Type 2.4AF CTD-10000 weighs only 25 kg/km in water (vs. 320 kg/km on steel-armored Type 2.3), preventing winch overload at 10,000 m |
| Optical telemetry capacity (REF 50580) | 21 × 9/125 μm singlemode fibers in 3 stainless-steel loose tubes (200 kpsi proof test; ≤0.4 dB/km at 1550 nm) |
| Operating temperature range | -30 °C to +70 °C (REF 57942, 39465, 26896); -20 °C to +70/+80 °C (REF 56427, 50108); -10 °C to +60 °C (REF 50580) |
| Commercial supply terms | Minimum order quantity 50 m; manufacturing lead time 7–45 working days |
| Model designation | Primary subsea application | Core & optical/coaxial construction | Voltage & impedance rating | Armor / strength member & breaking load | Hydrostatic pressure / depth rating | Nominal OD (mm) | Weight in air / seawater (kg/km) |
|---|---|---|---|---|---|---|---|
| Type 2.3 CTD-7000 | 7,000 m CTD Profiling Winch Umbilical | Insulated copper power & CTD telemetry conductors (≤10.0 Ω/km) | ≥1,000 MΩ·km @ DC 500 V | Double galvanized steel wire armor; ≥70 kN | ≥68 MPa (7,000 m) | 10.6 | 380 / 320 |
| Type 2.4AF CTD-10000 | 10,000 m Full-Ocean-Depth CTD Umbilical | Insulated copper power & CTD telemetry conductors (≤36.0 Ω/km) + inner/outer sheath | ≥1,000 MΩ·km @ DC 500 V | High-strength synthetic tensile fiber armor; ≥29 kN | ≥100 MPa (10,000 m+) | 10.6 | 120 / 25 |
| REF 56427 | Subsea Magnetic Detection Barrier | 4 × KU 06-16 triplets (12×1.34 mm² tinned copper, ETFE insulation, copper braid & ETFE sheath) | 600 V (≤15 Ω/km) | PE inner + Stainless-steel braid armor + PE outer; 1,500 daN | Subsea seabed crush-resistant | 25.0 ± 0.5 | 830 / — |
| REF 50108 | Subsea Acoustic Detection System | 3×0.6 mm² PE (1,000 V) + 2×1.0 mm² PE (500 V) + 1×4.0 mm² PP (500 V) + copper braid screen | 1,000 V / 500 V | HDPE inner + Galvanized steel wire armor + PUR; 8,900 daN | Deepwater acoustic array | 28.0 ± 1.0 | 1,280 / 650 |
| REF 52566 / REF 6050 | Inboard Ship Sonar HV Coax (DSM 40-01) | Tinned copper center + FEP dielectric + tinned-copper braid + rubberized tape + Neoprene | 4.5 kV peak (>1,000 MΩ·km @ 500 V) | Braided copper screen + Neoprene jacket | Shipboard sonar hull trunk | 11.0 ± 0.25 | 150 / — |
| REF 57942 | Inboard & Array 28-Pair Dynamic Sonar | 28 × 2 × 0.34 mm² extra-flexible tinned copper (TPE-E, individual copper-spun shield & TPE-E jacket) | 600 V; 40 ± 5 Ω pair impedance | Overall tinned-copper braid + PUR outer sheath | Dynamic sonar array (bend Ø ≥100/160 mm) | 25.0 ± 1.0 | 740 / — |
| REF 50580 | Underwater Neutrino Radiotelescope (-2,500 m) | 21 × 9/125 SM fibers in 3 SS loose tubes (7/tube) + 9 × 1.0 mm² XLPE copper cores | 600 V (≤22 Ω/km) | PE inner + Aramid fiber braid + PUR outer; ≥18,000 daN | 260 bar (2,600 m) | 30.0 ± 0.5 | 830 / 104 |
| REF 39465 | Deep-Ocean Seismic Detection Line (-2,000 m) | 2×2×0.22 mm² PP/PVC foil-shielded pairs + 1×2×1.5 mm² TPE-E foil-shielded pair + 3×1.5 mm² ballast | 600 V; 120 Ω (0.22² pairs) | HDPE inner + Aramid fiber braid + HDPE outer; 10,000 daN | 200+ bar (2,000 m) | 24.0 ± 1.0 | 507 / 43 |
| REF 26896 | Towed Sonar Buoy Triple-Coax Armored Cable | 3 × Coax (0.34 mm² silver-plated copper, FEP dielectric, silver-plated braid, ETFE jacket) | 50 Ω ≤ Z ≤ 60 Ω (10–200 MHz) | HDPE inner (9.7 mm) + Double galvanized steel wire armor; >9,000 daN | 250 bar (2,500 m) | ≤15.0 | 750 / 560 |
| Model & circuit group | DC resistance (@ 20 °C) or optical loss | Capacitance & characteristic impedance | HF attenuation performance | Min. static / dynamic bend radius | Operating temperature range |
|---|---|---|---|---|---|
| Type 2.3 CTD-7000 vs. Type 2.4AF CTD-10000 | Type 2.3: ≤10.0 Ω/km; Type 2.4AF: ≤36.0 Ω/km | Insulation resistance ≥1,000 MΩ·km @ DC 500 V | Real-time CTD sea-cable telemetry passband | Matched to Ø 10.6 mm oceanographic winch sheaves | Full-ocean-depth (-2 °C abyssal to +40 °C deck) |
| REF 52566 / REF 6050 (DSM 40-01 Sonar Coax) | High-conductivity tinned copper center & braid | 40 Ω (at 20 to 50 MHz); Capacitance <125 pF/m | 6.05 dB/100m @ 20 MHz; 7.45 dB/100m @ 30 MHz; 9.95 dB/100m @ 50 MHz | Flexible shipboard routing | Naval inboard sonar environment |
| REF 57942 (28-Pair Dynamic Sonar Cable) | 0.34 mm² conductors ≤62.8 Ω/km | 40 ± 5 Ω between conductors; Capacitance ≤180 pF/m | Low-crosstalk individual copper-spun pair shields + overall braid | Static bend Ø ≥100 mm / Dynamic bend Ø ≥160 mm | -30 °C to +70 °C |
| REF 56427 (Magnetic Detection KU 06-16 Triplets) | 1.34 mm² tinned copper conductors ≤15 Ω/km | 4 individually braided & ETFE-jacketed triplets | Low magnetic signature stainless-steel armor braid | Static bend radius ≥300 mm | -20 °C to +70 °C |
| REF 50108 (Acoustic Detection Multi-Gauge) | 0.6² ≤36 Ω/km; 1.0² ≤21 Ω/km; 4.0² ≤5.5 Ω/km | PE (0.6²/1.0²) & PP (4.0²) low-loss dielectrics | Overall copper braid shield under galvanized steel wire armor | Static ≥280 mm / Dynamic ≥560 mm | -20 °C to +80 °C |
| REF 50580 (21-Fiber + 9-Core Neutrino Cable) | 1.0 mm² XLPE ≤22 Ω/km; SM ≤0.6 dB/km (1310) & ≤0.4 dB/km (1550) | 200 kpsi proof-tested 9/125 SM fibers in 3 SS tubes | Optical amplifier feed at -2,500 m (260 bar) | Static bend radius ≥300 mm | -10 °C to +60 °C |
| REF 39465 & REF 26896 (Seismic & Sonar Buoy) | 39465: 0.22² ≤96, 1.5² ≤15 Ω/km; 26896: core ≤55, braid ≤35 Ω/km | 39465: 120 Ω, 40 pF/m; 26896: 50–60 Ω, ≤100 pF/m | REF 26896: ≤65 dB/km @ 10 MHz across 3 silver-plated FEP coax cores | REF 39465: Static ≥150 mm / Dynamic ≥370 mm | -30 °C to +70 °C |
All hydrostatic pressure ratings (68 MPa, 100 MPa, 250 bar, 260 bar), breaking loads, conductor resistances and air/seawater weights are taken directly from the engineering datasheets for Type 2.3 CTD-7000, Type 2.4AF CTD-10000, REF 56427, REF 50108, REF 52566 / 6050, REF 57942, REF 50580, REF 39465 and REF 26896.
Both Type 2.3 CTD-7000 and Type 2.4AF CTD-10000 share an identical 10.6 mm nominal outside diameter so oceanographic vessels can upgrade from 7,000 m steel-armored CTD wire to 10,000 m synthetic-fiber CTD umbilical using the same 10.6 mm winch Lebus groove shell and sheave blocks.
Hydrostatic qualification testing is supported up to 100 MPa (equivalent to 10,000 m water column) along with cyclic sheave fatigue testing up to 600 kN and tensile break testing up to 1,000 kN.
Standards
| Standard or specification | Application |
|---|---|
| IEC 60228 & IEC 61196 | Stranded bare, tinned and silver-plated copper conductors and high-frequency coaxial transmission parameters for sonar and oceanographic cables. |
| ITU-T G.652 & G.976 | Singlemode optical fiber transmission and submarine optical cable mechanical/hydrostatic test methods (REF 50580). |
| MIL-DTL-915 / Naval Sonar Impedance Basis | 40 Ω characteristic impedance and 4.5 kV peak pulse dielectric design for shipboard sonar transducer arrays (REF 6050 & REF 57942). |
| 100 MPa Full-Ocean-Depth Hydrostatic Verification | High-pressure vessel qualification to 68 MPa (7,000 m) and 100 MPa (10,000 m) for CTD profiling umbilicals. |
IEC 61196 Coaxial Communication Cables Standard Series at IEC Webstore
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
39–45 Ohm Coaxial Armoured Tow Cable
A related cable option for a different application or duty profile.
View product50 Ohm High-Voltage Coaxial Armoured Tow Cable
A related cable option for a different application or duty profile.
View productArmoured Underwater Instrumentation Cable
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.